FCC ID 2BUQI-DT66HC
Mobile Data terminal
by Urovo Healthcare Co., Ltd
Grantee Code: 2BUQI Product Code: DT66HC
Latest application date: 2026-03-06
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 13.56 MHz | Change in identification of presently authorized equipment. Original FCC ID: SWSDT66 Grant Date: 01/02/2025 | 2026-03-06 |
| 5745-5825 MHz | Change in identification of presently authorized equipment. Original FCC ID: SWSDT66 Grant Date: 01/02/2025 | 2026-03-06 |
| 2412-2462 MHz | Change in identification of presently authorized equipment. Original FCC ID: SWSDT66 Grant Date: 01/02/2025 | 2026-03-06 |
| 2402-2480 MHz | Change in identification of presently authorized equipment. Original FCC ID: SWSDT66 Grant Date: 01/02/2025 | 2026-03-06 |
| 3750-3930 MHz | Change in identification of presently authorized equipment. Original FCC ID: SWSDT66 Grant Date: 01/02/2025 | 2026-03-06 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User_Manual | Users Manual | 2026-09-02 | PDF 2.5 MB |
| external_photo | External Photos | 2026-09-02 | PDF 2.5 MB |
| Label | ID Label/Location Info | 2026-03-06 | PDF 112.7 KB |
| Attestation_Letter_COVERED_EQUIPMENT | Attestation Statements | 2026-03-06 | PDF 116.6 KB |
| Attestation_Letter_US_Agent | Attestation Statements | 2026-03-06 | PDF 135.1 KB |
| Authorization_Letter | Cover Letter(s) | 2026-03-06 | PDF 74.7 KB |
| Confidentiality_Request_Letter | Cover Letter(s) | 2026-03-06 | PDF 104 KB |
| FCC_2933_ChangeID_New_Grantee | Cover Letter(s) | 2026-03-06 | PDF 91.4 KB |
| Permission_Letter_by_Original_Applicant | Cover Letter(s) | 2026-03-06 | PDF 204.8 KB |
Application Information
| Application ID | iOz730O8FFloOIQ5D36uhg== |
|---|---|
| Final Action Date | 2026-03-06 |
| Application Purpose | Change in identification of presently authorized equipment. Original FCC ID: SWSDT66 Grant Date: 01/02/2025 |
| Applicant FRN | 0037953288 |
| Model | DT66HC |
| Frequency Range | 13.56 MHz |
| Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter |
| Device Description | Mobile Data terminal |
| Responsible Party | yantong Hu, yantong.hu@urovo.com |
| Non-Technical Contact | Ivan Wang, Picus Advisors US LLC, ivan.wang@picus.fi |
| Test Firm | Hanson Lin, Shenzhen BALUN Technology Co., Ltd., Hanson.Lin@baluntek.com |
| TCB Email | bentje.holger@phoenix-testlab.de |
| TCB Scope | A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices |
| Short-Term Confidentiality | Yes |
| Long-Term Confidentiality | Yes |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| iOz730O8FFloOIQ5D36uhg== | 2026-03-06 | Change in identification of presently authorized equipment. Original FCC ID: SWSDT66 Grant Date: 01/02/2025 |
| iAwzPV+poJ8acQPvzv8Ocw== | 2026-03-06 | Change in identification of presently authorized equipment. Original FCC ID: SWSDT66 Grant Date: 01/02/2025 |
| hsEgBQqPr80YHNRdt0v2Eg== | 2026-03-06 | Change in identification of presently authorized equipment. Original FCC ID: SWSDT66 Grant Date: 01/02/2025 |
| a+6qPwPGD6XxSPFCjD/tTg== | 2026-03-06 | Change in identification of presently authorized equipment. Original FCC ID: SWSDT66 Grant Date: 01/02/2025 |
| QWGJw6IZrD7eWiBi3sLKYA== | 2026-03-06 | Change in identification of presently authorized equipment. Original FCC ID: SWSDT66 Grant Date: 01/02/2025 |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 824.2-848.8 MHz | 0.673 | 2.5 PM | 244MGXW | 22H | |
| 824.2-848.8 MHz | 0.303 | 2.5 PM | 247MG7W | 22H | |
| 826.4-846.6 MHz | 0.06 | 2.5 PM | 4M13F9W | 22H | |
| 829-844 MHz | 0.076 | 2.5 PM | 9M00G7D | 22H | |
| 829-844 MHz | 0.065 | 2.5 PM | 9M00W7D | 22H | |
| 824.7-848.3 MHz | 0.066 | 2.5 PM | 1M10W7D | 22H | |
| 831.5-841.5 MHz | 0.05 | 2.5 PM | 13M5G7D | 22H | |
| 831.5-841.5 MHz | 0.043 | 2.5 PM | 13M5W7D | 22H | |
| 824.7-848.3 MHz | 0.052 | 2.5 PM | 1M10G7D | 22H | |
| 824.7-848.3 MHz | 0.045 | 2.5 PM | 1M10W7D | 22H | |
| 834-839 MHz | 0.075 | 2.5 PM | 18M9G7D | 22H | |
| 834-839 MHz | 0.058 | 2.5 PM | 19M0W7D | 22H | |
| 834-839 MHz | 0.076 | 2.5 PM | 18M9G7D | 22H | |
| 834-839 MHz | 0.061 | 2.5 PM | 18M9W7D | 22H | |
| 1850.2-1909.8 MHz | 1.799 | 2.5 PM | 245MGXW | 24E | |
| 1850.2-1909.8 MHz | 1.309 | 2.5 PM | 248MG7W | 24E | |
| 1852.4-1907.6 MHz | 0.279 | 2.5 PM | 4M15F9W | 24E | |
| 1860-1900 MHz | 0.344 | 2.5 PM | 18M0G7D | 24E | |
| 1860-1900 MHz | 0.297 | 2.5 PM | 18M0W7D | 24E | |
| 1850.7-1909.3 MHz | 0.361 | 2.5 PM | 1M09G7D | 24E | |
| 1851.5-1908.5 MHz | 0.318 | 2.5 PM | 2M70W7D | 24E | |
| 1860-1905 MHz | 0.301 | 2.5 PM | 18M0G7D | 24E | |
| 1860-1905 MHz | 0.265 | 2.5 PM | 18M0W7D | 24E | |
| 1850.7-1914.3 MHz | 0.313 | 2.5 PM | 1M09G7D | 24E | |
| 1852.5-1912.5 MHz | 0.275 | 2.5 PM | 4M51W7D | 24E | |
| 1860-1900 MHz | 0.332 | 2.5 PM | 18M9G7D | 24E | |
| 1860-1900 MHz | 0.257 | 2.5 PM | 19M0W7D | 24E | |
| 1852.5-1907.5 MHz | 0.265 | 2.5 PM | 4M58W7D | 24E | |
| 1860-1905 MHz | 0.34 | 2.5 PM | 18M9G7D | 24E | |
| 1860-1905 MHz | 0.267 | 2.5 PM | 19M0W7D | 24E | |
| 1712.4-1752.6 MHz | 0.182 | 2.5 PM | 4M15F9W | 27 | |
| 1720-1745 MHz | 0.22 | 2.5 PM | 18M0G7D | 27 | |
| 1720-1745 MHz | 0.191 | 2.5 PM | 18M0W7D | 27 | |
| 1712.5-1752.5 MHz | 0.232 | 2.5 PM | 4M51G7D | 27 | |
| 1712.5-1752.5 MHz | 0.199 | 2.5 PM | 4M50W7D | 27 | |
| 2510-2560 MHz | 0.152 | 2.5 PM | 18M0G7D | 27 | |
| 2510-2560 MHz | 0.132 | 2.5 PM | 18M0W7D | 27 | |
| 2505-2565 MHz | 0.157 | 2.5 PM | 9M00G7D | 27 | |
| 2502.5-2567.5 MHz | 0.139 | 2.5 PM | 4M51W7D | 27 | |
| 704-711 MHz | 0.038 | 2.5 PM | 9M00G7D | 27 | |
| 704-711 MHz | 0.033 | 2.5 PM | 9M00W7D | 27 | |
| 699.7-715.3 MHz | 0.034 | 2.5 PM | 1M10W7D | 27 | |
| 782 MHz | 0.051 | 2.5 PM | 8M99G7D | 27 | |
| 782 MHz | 0.044 | 2.5 PM | 8M98W7D | 27 | |
| 709-711 MHz | 0.038 | 2.5 PM | 8M99G7D | 27 | |
| 709-711 MHz | 0.033 | 2.5 PM | 8M98W7D | 27 | |
| 2580-2610 MHz | 0.174 | 2.5 PM | 18M0G7D | 27 | |
| 2580-2610 MHz | 0.147 | 2.5 PM | 18M1W7D | 27 | |
| 2575-2615 MHz | 0.178 | 2.5 PM | 9M03G7D | 27 | |
| 2572.5-2617.5 MHz | 0.15 | 2.5 PM | 4M53G7D | 27 | |
| 2506-2680 MHz | 0.177 | 2.5 PM | 18M0G7D | 27 | |
| 2506-2680 MHz | 0.149 | 2.5 PM | 18M0W7D | 27 | |
| 2501-2685 MHz | 0.179 | 2.5 PM | 9M05G7D | 27 | |
| 2498.5-2687.5 MHz | 0.152 | 2.5 PM | 4M51W7D | 27 | |
| 1720-1770 MHz | 0.265 | 2.5 PM | 18M0G7D | 27 | |
| 1720-1770 MHz | 0.242 | 2.5 PM | 18M0W7D | 27 | |
| 1715-1775 MHz | 0.271 | 2.5 PM | 9M00G7D | 27 | |
| 673-688 MHz | 0.035 | 2.5 PM | 18M0G7D | 27 | |
| 673-688 MHz | 0.029 | 2.5 PM | 18M0W7D | 27 | |
| 665.5-695.5 MHz | 0.036 | 2.5 PM | 4M51G7D | 27 | |
| 2510-2560 MHz | 0.208 | 2.5 PM | 19M0G7D | 27 | |
| 2507.5-2562.5 MHz | 0.211 | 2.5 PM | 14M1G7D | 27 | |
| 2510-2560 MHz | 0.163 | 2.5 PM | 19M0W7D | 27 | |
| 2502.5-2567.5 MHz | 0.167 | 2.5 PM | 4M58W7D | 27 | |
| 706.5-708.5 MHz | 0.039 | 2.5 PM | 14M1G7D | 27 | |
| 706.5-708.5 MHz | 0.031 | 2.5 PM | 14M1W7D | 27 | |
| 779.5-784.5 MHz | 0.049 | 2.5 PM | 4M52G7D | 27 | |
| 782 MHz | 0.048 | 2.5 PM | 9M26G7D | 27 | |
| 779.5-784.5 MHz | 0.039 | 2.5 PM | 4M54W7D | 27 | |
| 782 MHz | 0.037 | 2.5 PM | 9M28W7D | 27 | |
| 2590-2600 MHz | 0.219 | 2.5 PM | 38M1G7D | 27 | |
| 2590-2600 MHz | 0.175 | 2.5 PM | 38M3W7D | 27 | |
| 2506.02-2679.99 MHz | 0.344 | 2.5 PM | 18M2G7D | 27 | |
| 2546.01-2640 MHz | 0.33 | 2.5 PM | 97M6G7D | 27 | |
| 2506.02-2679.99 MHz | 0.272 | 2.5 PM | 18M3W7D | 27 | |
| 2546.01-2640 MHz | 0.263 | 2.5 PM | 97M5W7D | 27 | |
| 1717.5-1772.5 MHz | 0.272 | 2.5 PM | 14M1G7D | 27 | |
| 1720-1770 MHz | 0.265 | 2.5 PM | 19M0G7D | 27 | |
| 1717.5-1772.5 MHz | 0.211 | 2.5 PM | 14M1W7D | 27 | |
| 1720-1770 MHz | 0.205 | 2.5 PM | 19M0W7D | 27 | |
| 673-688 MHz | 0.037 | 2.5 PM | 18M9G7D | 27 | |
| 673-688 MHz | 0.029 | 2.5 PM | 18M9W7D | 27 | |
| 3480-3519.99 MHz | 0.348 | 2.5 PM | 58M0G7D | 27 | |
| 3499.98 MHz | 0.321 | 2.5 PM | 97M4G7D | 27 | |
| 3460.02-3540 MHz | 0.27 | 2.5 PM | 18M3W7D | 27 | |
| 3499.98 MHz | 0.255 | 2.5 PM | 97M4W7D | 27 | |
| 3730.02-3949.98 MHz | 0.92 | 2.5 PM | 58M1G7D | 27 | |
| 3750-3930 MHz | 0.824 | 2.5 PM | 97M6G7D | 27 | |
| 3730.02-3949.98 MHz | 0.695 | 2.5 PM | 18M2W7D | 27 | |
| 3510-3649.98 MHz | 0.653 | 2.5 PM | 97M5W7D | 27 | |
| 3460.02-3540 MHz | 0.341 | 2.5 PM | 18M2G7D | 27 | |
| 3499.98 MHz | 0.325 | 2.5 PM | 97M4G7D | 27 | |
| 3460.02-3540 MHz | 0.273 | 2.5 PM | 18M3W7D | 27 | |
| 3499.98 MHz | 0.254 | 2.5 PM | 97M4W7D | 27 | |
| 3710.01-3789.99 MHz | 0.667 | 2.5 PM | 18M2G7D | 27 | |
| 3750 MHz | 0.637 | 2.5 PM | 97M3G7D | 27 | |
| 3710.01-3789.99 MHz | 0.537 | 2.5 PM | 18M3W7D | 27 | |
| 3750 MHz | 0.5 | 2.5 PM | 97M3W7D | 27 | |
| 819 MHz | 0.061 | 2.5 PM | 9M01G7D | 90 | |
| 819 MHz | 0.054 | 2.5 PM | 9M00W7D | 90 | |
| 819.5-821.5 MHz | 0.064 | 2.5 PM | 4M53G7D | 90 | |
| 819 MHz | 0.063 | 2.5 PM | 9M27G7D | 90 | |
| 819.5-821.5 MHz | 0.051 | 2.5 PM | 4M53W7D | 90 | |
| 819 MHz | 0.05 | 2.5 PM | 9M28W7D | 90 | |
| 13.56 MHz | 15C | CC | |||
| 5180-5240 MHz | 0.07798 | 15E | CC MO | ||
| 5260-5320 MHz | 0.07816 | 15E | CC MO | ||
| 5500-5700 MHz | 0.07925 | 15E | CC MO | ||
| 5745-5825 MHz | 0.03899 | 15E | CC MO | ||
| 2402-2480 MHz | 0.00796 | 15C | CC | ||
| 2412-2462 MHz | 0.36728 | 15C | CC MO | ||
| 2402-2480 MHz | 0.00948 | 15C | CC |
Grants
TCB Grant - Application QWGJw6IZrD7eWiBi3sLKYA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 03/06/2026 Application Dated: 03/05/2026 |
| Urovo Healthcare Co., Ltd |
| Room 902, building 4, 588 Qinzheng Road, Hengqin |
| New Area, |
| Zhuhai, Guangdong,, China |
| Attention: yantong Hu , product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BUQI-DT66HC |
| Name of Grantee: | Urovo Healthcare Co., Ltd |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | Mobile Data terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 0.673 | 2.5 PM | 244MGXW | |
| 22H | 824.2 - 848.8 | 0.303 | 2.5 PM | 247MG7W | |
| 22H | 826.4 - 846.6 | 0.06 | 2.5 PM | 4M13F9W | |
| 22H | 829.0 - 844.0 | 0.076 | 2.5 PM | 9M00G7D | |
| 22H | 829.0 - 844.0 | 0.065 | 2.5 PM | 9M00W7D | |
| 22H | 824.7 - 848.3 | 0.066 | 2.5 PM | 1M10W7D | |
| 22H | 831.5 - 841.5 | 0.05 | 2.5 PM | 13M5G7D | |
| 22H | 831.5 - 841.5 | 0.043 | 2.5 PM | 13M5W7D | |
| 22H | 824.7 - 848.3 | 0.052 | 2.5 PM | 1M10G7D | |
| 22H | 824.7 - 848.3 | 0.045 | 2.5 PM | 1M10W7D | |
| 22H | 834.0 - 839.0 | 0.075 | 2.5 PM | 18M9G7D | |
| 22H | 834.0 - 839.0 | 0.058 | 2.5 PM | 19M0W7D | |
| 22H | 834.0 - 839.0 | 0.076 | 2.5 PM | 18M9G7D | |
| 22H | 834.0 - 839.0 | 0.061 | 2.5 PM | 18M9W7D | |
| 24E | 1850.2 - 1909.8 | 1.799 | 2.5 PM | 245MGXW | |
| 24E | 1850.2 - 1909.8 | 1.309 | 2.5 PM | 248MG7W | |
| 24E | 1852.4 - 1907.6 | 0.279 | 2.5 PM | 4M15F9W | |
| 24E | 1860.0 - 1900.0 | 0.344 | 2.5 PM | 18M0G7D | |
| 24E | 1860.0 - 1900.0 | 0.297 | 2.5 PM | 18M0W7D | |
| 24E | 1850.7 - 1909.3 | 0.361 | 2.5 PM | 1M09G7D | |
| 24E | 1851.5 - 1908.5 | 0.318 | 2.5 PM | 2M70W7D | |
| 24E | 1860.0 - 1905.0 | 0.301 | 2.5 PM | 18M0G7D | |
| 24E | 1860.0 - 1905.0 | 0.265 | 2.5 PM | 18M0W7D | |
| 24E | 1850.7 - 1914.3 | 0.313 | 2.5 PM | 1M09G7D | |
| 24E | 1852.5 - 1912.5 | 0.275 | 2.5 PM | 4M51W7D | |
| 24E | 1860.0 - 1900.0 | 0.332 | 2.5 PM | 18M9G7D | |
| 24E | 1860.0 - 1900.0 | 0.257 | 2.5 PM | 19M0W7D | |
| 24E | 1852.5 - 1907.5 | 0.265 | 2.5 PM | 4M58W7D | |
| 24E | 1860.0 - 1905.0 | 0.34 | 2.5 PM | 18M9G7D | |
| 24E | 1860.0 - 1905.0 | 0.267 | 2.5 PM | 19M0W7D | |
| 27 | 1712.4 - 1752.6 | 0.182 | 2.5 PM | 4M15F9W | |
| 27 | 1720.0 - 1745.0 | 0.22 | 2.5 PM | 18M0G7D | |
| 27 | 1720.0 - 1745.0 | 0.191 | 2.5 PM | 18M0W7D | |
| 27 | 1712.5 - 1752.5 | 0.232 | 2.5 PM | 4M51G7D | |
| 27 | 1712.5 - 1752.5 | 0.199 | 2.5 PM | 4M50W7D | |
| 27 | 2510.0 - 2560.0 | 0.152 | 2.5 PM | 18M0G7D | |
| 27 | 2510.0 - 2560.0 | 0.132 | 2.5 PM | 18M0W7D | |
| 27 | 2505.0 - 2565.0 | 0.157 | 2.5 PM | 9M00G7D | |
| 27 | 2502.5 - 2567.5 | 0.139 | 2.5 PM | 4M51W7D | |
| 27 | 704.0 - 711.0 | 0.038 | 2.5 PM | 9M00G7D | |
| 27 | 704.0 - 711.0 | 0.033 | 2.5 PM | 9M00W7D | |
| 27 | 699.7 - 715.3 | 0.034 | 2.5 PM | 1M10W7D | |
| 27 | 782.0 - 782.0 | 0.051 | 2.5 PM | 8M99G7D | |
| 27 | 782.0 - 782.0 | 0.044 | 2.5 PM | 8M98W7D | |
| 27 | 709.0 - 711.0 | 0.038 | 2.5 PM | 8M99G7D | |
| 27 | 709.0 - 711.0 | 0.033 | 2.5 PM | 8M98W7D | |
| 27 | 2580.0 - 2610.0 | 0.174 | 2.5 PM | 18M0G7D | |
| 27 | 2580.0 - 2610.0 | 0.147 | 2.5 PM | 18M1W7D | |
| 27 | 2575.0 - 2615.0 | 0.178 | 2.5 PM | 9M03G7D | |
| 27 | 2572.5 - 2617.5 | 0.15 | 2.5 PM | 4M53G7D | |
| 27 | 2506.0 - 2680.0 | 0.177 | 2.5 PM | 18M0G7D | |
| 27 | 2506.0 - 2680.0 | 0.149 | 2.5 PM | 18M0W7D | |
| 27 | 2501.0 - 2685.0 | 0.179 | 2.5 PM | 9M05G7D | |
| 27 | 2498.5 - 2687.5 | 0.152 | 2.5 PM | 4M51W7D | |
| 27 | 1720.0 - 1770.0 | 0.265 | 2.5 PM | 18M0G7D | |
| 27 | 1720.0 - 1770.0 | 0.242 | 2.5 PM | 18M0W7D | |
| 27 | 1715.0 - 1775.0 | 0.271 | 2.5 PM | 9M00G7D | |
| 27 | 673.0 - 688.0 | 0.035 | 2.5 PM | 18M0G7D | |
| 27 | 673.0 - 688.0 | 0.029 | 2.5 PM | 18M0W7D | |
| 27 | 665.5 - 695.5 | 0.036 | 2.5 PM | 4M51G7D | |
| 27 | 2510.0 - 2560.0 | 0.208 | 2.5 PM | 19M0G7D | |
| 27 | 2507.5 - 2562.5 | 0.211 | 2.5 PM | 14M1G7D | |
| 27 | 2510.0 - 2560.0 | 0.163 | 2.5 PM | 19M0W7D | |
| 27 | 2502.5 - 2567.5 | 0.167 | 2.5 PM | 4M58W7D | |
| 27 | 706.5 - 708.5 | 0.039 | 2.5 PM | 14M1G7D | |
| 27 | 706.5 - 708.5 | 0.031 | 2.5 PM | 14M1W7D | |
| 27 | 779.5 - 784.5 | 0.049 | 2.5 PM | 4M52G7D | |
| 27 | 782.0 - 782.0 | 0.048 | 2.5 PM | 9M26G7D | |
| 27 | 779.5 - 784.5 | 0.039 | 2.5 PM | 4M54W7D | |
| 27 | 782.0 - 782.0 | 0.037 | 2.5 PM | 9M28W7D | |
| 27 | 2590.0 - 2600.0 | 0.219 | 2.5 PM | 38M1G7D | |
| 27 | 2590.0 - 2600.0 | 0.175 | 2.5 PM | 38M3W7D | |
| 27 | 2506.02 - 2679.99 | 0.344 | 2.5 PM | 18M2G7D | |
| 27 | 2546.01 - 2640.0 | 0.33 | 2.5 PM | 97M6G7D | |
| 27 | 2506.02 - 2679.99 | 0.272 | 2.5 PM | 18M3W7D | |
| 27 | 2546.01 - 2640.0 | 0.263 | 2.5 PM | 97M5W7D | |
| 27 | 1717.5 - 1772.5 | 0.272 | 2.5 PM | 14M1G7D | |
| 27 | 1720.0 - 1770.0 | 0.265 | 2.5 PM | 19M0G7D | |
| 27 | 1717.5 - 1772.5 | 0.211 | 2.5 PM | 14M1W7D | |
| 27 | 1720.0 - 1770.0 | 0.205 | 2.5 PM | 19M0W7D | |
| 27 | 673.0 - 688.0 | 0.037 | 2.5 PM | 18M9G7D | |
| 27 | 673.0 - 688.0 | 0.029 | 2.5 PM | 18M9W7D | |
| 27 | 3480.0 - 3519.99 | 0.348 | 2.5 PM | 58M0G7D | |
| 27 | 3499.98 - 3499.98 | 0.321 | 2.5 PM | 97M4G7D | |
| 27 | 3460.02 - 3540.0 | 0.27 | 2.5 PM | 18M3W7D | |
| 27 | 3499.98 - 3499.98 | 0.255 | 2.5 PM | 97M4W7D | |
| 27 | 3730.02 - 3949.98 | 0.92 | 2.5 PM | 58M1G7D | |
| 27 | 3750.0 - 3930.0 | 0.824 | 2.5 PM | 97M6G7D | |
| 27 | 3730.02 - 3949.98 | 0.695 | 2.5 PM | 18M2W7D | |
| 27 | 3510.0 - 3649.98 | 0.653 | 2.5 PM | 97M5W7D | |
| 27 | 3460.02 - 3540.0 | 0.341 | 2.5 PM | 18M2G7D | |
| 27 | 3499.98 - 3499.98 | 0.325 | 2.5 PM | 97M4G7D | |
| 27 | 3460.02 - 3540.0 | 0.273 | 2.5 PM | 18M3W7D | |
| 27 | 3499.98 - 3499.98 | 0.254 | 2.5 PM | 97M4W7D | |
| 27 | 3710.01 - 3789.99 | 0.667 | 2.5 PM | 18M2G7D | |
| 27 | 3750.0 - 3750.0 | 0.637 | 2.5 PM | 97M3G7D | |
| 27 | 3710.01 - 3789.99 | 0.537 | 2.5 PM | 18M3W7D | |
| 27 | 3750.0 - 3750.0 | 0.5 | 2.5 PM | 97M3W7D | |
| 90 | 819.0 - 819.0 | 0.061 | 2.5 PM | 9M01G7D | |
| 90 | 819.0 - 819.0 | 0.054 | 2.5 PM | 9M00W7D | |
| 90 | 819.5 - 821.5 | 0.064 | 2.5 PM | 4M53G7D | |
| 90 | 819.0 - 819.0 | 0.063 | 2.5 PM | 9M27G7D | |
| 90 | 819.5 - 821.5 | 0.051 | 2.5 PM | 4M53W7D | |
| 90 | 819.0 - 819.0 | 0.05 | 2.5 PM | 9M28W7D |
| Output power listed for GSM850, WCDMA Band 5, LTE Band 5/12/13/17/26/71, 5GNR n5/n12/n13/n26/n71 are maximum ERP, except Part 90 operations, which are conducted. Output power listed for PCS1900, WCDMA Band 2/4, LTE Band 2/4/7/25/38/41/66, 5GNR n2/n7/n25/n38/n41/n77/n78 are maximum EIRP. It supports GSM, WCDMA, LTE (QPSK, 16QAM, 64QAM), 5G NR operation mode includes Standalone and Non-standalone (EN-DC): Modulation: CP-OFDM QPSK, 16QAM, 64QAM, 256QAM and DFT-s-OFDM PI/2 BPSK, QPSK, 16QAM, 64QAM, 256QAM. LTE B2, B4, B5, B7, B12, B13, B17, B25, B26, B38, B41, B66, B71 5G NR n2, n5, n7, n12, n13, n25, n26, n38, n41, n66, n71, n77, n78 Channel Bandwidth (1.4/3/5/10 MHz) for LTE B5, B12, Channel Bandwidth (1.4/3/5/10/15 MHz) for LTE B26, Channel Bandwidth (1.4/3/5/10/15/20 MHz) for LTE B2, B4, B25, B66, Channel Bandwidth (5/10 MHz) for LTE B13, B17, 5GNR n13, Channel Bandwidth (5/10/15 MHz) for 5GNR n12, Channel Bandwidth (5/10/15/20 MHz) for LTE B7, B38, B41, B71, 5G NR n2, n5, n7, n25, n26, n66, n71, Channel Bandwidth (20/30/40 MHz) for 5G NR n38, Channel Bandwidth (20/30/40/50/60/70/80/90/100 MHz) for 5G NR n41, Channel Bandwidth (20/30/40/60/80/100 MHz) for 5G NR n77, Channel Bandwidth (20/30/40/50/60/70/80/90/100 MHz) for 5G NR n78, This device contains functions that are not operational in U.S. Territories; this filing is only applicable for U.S. operations. This device has integrated DXX, DTS, DSS, NII and PCE transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for Head, body-worn accessory, hotspot and simultaneous transmission use conditions are 1.01 W/kg, 0.65 W/kg, 0.65 W/kg, and 1.56 W/kg, respectively. Product specific SAR at 10-gram tissue is 1.98 W/kg. |
TCB Grant - Application iOz730O8FFloOIQ5D36uhg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 03/06/2026 Application Dated: 03/05/2026 |
| Urovo Healthcare Co., Ltd |
| Room 902, building 4, 588 Qinzheng Road, Hengqin |
| New Area, |
| Zhuhai, Guangdong,, China |
| Attention: yantong Hu , product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BUQI-DT66HC |
| Name of Grantee: | Urovo Healthcare Co., Ltd |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Mobile Data terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 13.56 - 13.56 |
| This device has integrated DXX, DSS, DTS, NII and PCE transmitters certified under the same FCC ID. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application iAwzPV+poJ8acQPvzv8Ocw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 03/06/2026 Application Dated: 03/05/2026 |
| Urovo Healthcare Co., Ltd |
| Room 902, building 4, 588 Qinzheng Road, Hengqin |
| New Area, |
| Zhuhai, Guangdong,, China |
| Attention: yantong Hu , product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BUQI-DT66HC |
| Name of Grantee: | Urovo Healthcare Co., Ltd |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Mobile Data terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.07798 | ||
| CC MO | 15E | 5260.0 - 5320.0 | 0.07816 | ||
| CC MO | 15E | 5500.0 - 5700.0 | 0.07925 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.03899 |
| Output power is maximum average conducted. This device supports IEEE 802.11 a/n/ac/ax 20, 40, 80 and 160 MHz channel bandwidths. This device has integrated DXX, DSS, DTS, NII and PCE transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. The highest reported SAR values for head, body-worn accessory, hotspot and simultaneous transmission use conditions are 0.39 W/kg, 0.43 W/kg, 0.44 W/kg, and 1.56 W/kg, respectively. Product specific SAR at 10-gram tissue is 0.99 W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
TCB Grant - Application hsEgBQqPr80YHNRdt0v2Eg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 03/06/2026 Application Dated: 03/05/2026 |
| Urovo Healthcare Co., Ltd |
| Room 902, building 4, 588 Qinzheng Road, Hengqin |
| New Area, |
| Zhuhai, Guangdong,, China |
| Attention: yantong Hu , product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BUQI-DT66HC |
| Name of Grantee: | Urovo Healthcare Co., Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Mobile Data terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00796 | ||
| CC MO | 15C | 2412.0 - 2462.0 | 0.36728 |
| Output power is maximum peak conducted. This device supports IEEE 802.11 b/g/n20/ax20 MHz channel bandwidths. This device has integrated DXX, DSS, DTS, NII and PCE transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn accessory, hotspot and simultaneous transmission use conditions are 0.33 W/kg, 0.25 W/kg, 0.25 W/kg, and 1.56 W/kg, respectively. Product specific SAR at 10-gram tissue is 0.95 W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
TCB Grant - Application a+6qPwPGD6XxSPFCjD/tTg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 03/06/2026 Application Dated: 03/05/2026 |
| Urovo Healthcare Co., Ltd |
| Room 902, building 4, 588 Qinzheng Road, Hengqin |
| New Area, |
| Zhuhai, Guangdong,, China |
| Attention: yantong Hu , product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BUQI-DT66HC |
| Name of Grantee: | Urovo Healthcare Co., Ltd |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Mobile Data terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00948 |
| Output power is maximum peak conducted. This device has integrated DXX, DSS, DTS, NII and PCE transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn accessory, hotspot and simultaneous transmission use conditions are <0.10 W/kg, <0.10 W/kg, <0.10 W/kg and 1.44 W/kg, respectively. Product specific SAR at 10-gram tissue is <0.10 W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |