FCC ID 2BWTH-IWT1
Infinity Watch
by MediBioSense Ltd
Grantee Code: 2BWTH Product Code: IWT1
Latest application date: 2026-10-31
FCC ID Device Details
| FCC ID | 2BWTH-IWT1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2BWTH |
| Product Code | IWT1 |
| Applicant Business | MediBioSense Ltd 🇬🇧 |
| Equipment Class | Infinity Watch |
| Test Firm | Shenzhen BKC Testing Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 13.56 MHz | Original Equipment | 2026-10-31 |
| 2402-2480 MHz | Original Equipment | 2026-10-31 |
| 2580-2610 MHz | Original Equipment | 2026-10-31 |
| 2412-2462 MHz | Original Equipment | 2026-10-31 |
| 5725-5850 MHz | Original Equipment | 2026-10-30 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Label and Information | ID Label/Location Info | 2026-10-31 | PDF 235.7 KB |
| label and location | ID Label/Location Info | 2026-10-31 | PDF 235.7 KB |
| ANT spe | Test Report | 2026-10-31 | PDF 75 KB |
| Antenna Specification | Test Report | 2026-10-31 | PDF 1.3 MB |
| Test Report | Test Report | 2026-10-31 | PDF 569.6 KB |
| Test Report | Test Report | 2026-10-31 | PDF 1,006 KB |
| Test Report | Test Report | 2026-10-31 | PDF 961.7 KB |
| test report | Test Report | 2026-10-31 | PDF 1.2 MB |
| Test Report | Test Report | 2026-10-30 | PDF 2.3 MB |
| 3.Attestation_Statements_part_2.911_d__5__i__and_2.911_d__5__ii_(4)(3) | Attestation Statements | 2026-10-31 | PDF 103.3 KB |
| Antenna Specification | Attestation Statements | 2026-10-31 | PDF 1.3 MB |
| Attestation Statements of US Agent for Service of Process, 2.911(d)(7) | Attestation Statements | 2026-10-31 | PDF 145.2 KB |
| Attestation of Covered Equipment, 2.911(d)(5)(i)(ii) | Attestation Statements | 2026-10-31 | PDF 103.3 KB |
| USA AGENT letter | Attestation Statements | 2026-10-31 | PDF 145.2 KB |
| Agent Authorization Letter | Cover Letter(s) | 2026-10-31 | PDF 173.9 KB |
| Agent Authorization Letter Template | Cover Letter(s) | 2026-10-31 | PDF 173.9 KB |
| FCC Short- & Long-Term Confidentiality Request | Cover Letter(s) | 2026-10-31 | PDF 93 KB |
| Family model letter | Cover Letter(s) | 2026-10-31 | PDF 86.7 KB |
| Model Difference | Cover Letter(s) | 2026-10-31 | PDF 86.7 KB |
| FCC Software Configuration Control Declaration | Cover Letter(s) | 2026-10-30 | PDF 159.5 KB |
| RF EXPOSURE REPORT | RF Exposure Info | 2026-10-31 | PDF 4 MB |
| RF Exposure Info | RF Exposure Info | 2026-10-31 | PDF 4 MB |
| RF Exposure Report | RF Exposure Info | 2026-10-31 | PDF 4 MB |
| RF exposure | RF Exposure Info | 2026-10-31 | PDF 4.2 MB |
| User Manual Metadata only | Users Manual | 2027-04-29 | PDF 320.5 KB |
| user manual Metadata only | Users Manual | 2027-04-29 | PDF 320.5 KB |
| Internal Photos Metadata only | Internal Photos | 2027-04-29 | PDF 2.3 MB |
| internal photo Metadata only | Internal Photos | 2027-04-29 | PDF 2.3 MB |
| External Photos Metadata only | External Photos | 2027-04-29 | PDF 893.5 KB |
| External photo Metadata only | External Photos | 2027-04-29 | PDF 893.5 KB |
| Test Setup Photos Metadata only | Test Setup Photos | 2027-04-29 | PDF 245.5 KB |
| Test Setup Photos Metadata only | Test Setup Photos | 2027-04-29 | PDF 909.3 KB |
| test photo Metadata only | Test Setup Photos | 2027-04-29 | PDF 909.3 KB |
| BLOCK Metadata only | Block Diagram | PDF 69.9 KB | |
| block diagram Metadata only | Block Diagram | PDF 69.9 KB | |
| SCH Metadata only | Schematics | PDF 671.3 KB | |
| OPS Metadata only | Operational Description | PDF 89.2 KB | |
| OPS Metadata only | Operational Description | PDF 167.2 KB | |
| Operational Description Metadata only | Operational Description | PDF 89.2 KB | |
| FCC Software Security Requirements for UNII devices Metadata only | SDR Software/Security Info. | PDF 150.7 KB | |
| SOFTWARE SECURITY REQUIREMENTS FOR U-NII DEVICES Metadata only | SDR Software/Security Info. | PDF 150.7 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 167.2 KB | |
| Tune up Procedure Metadata only | Parts List/Tune Up Info | PDF 83.2 KB |
Application Information
| Application ID | podQshx3+WOiTMNgy2ZTZw== |
|---|---|
| Final Action Date | 2026-10-31 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0038591202 |
| Model | IWT1 |
| Frequency Range | 13.56 MHz |
| Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter |
| Device Description | Infinity Watch |
| Responsible Party | Simon Beniston, xulangkeji163@163.com |
| Technical Contact | MediBioSense Ltd, xulangkeji163@163.com |
| Non-Technical Contact | Yangyang Xu, HOPEK CORPORATION INC, HopekPeter@gmail.com |
| Test Firm | Levi Xiao, Shenzhen BKC Testing Co., Ltd., xiaoqiuming@bkc-lab.com |
| TCB Email | anezam@qai.org |
| TCB Scope | A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices |
| Short-Term Confidentiality | Yes |
| Long-Term Confidentiality | Yes |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| podQshx3+WOiTMNgy2ZTZw== | 2026-10-31 | Original Equipment |
| kTbjlWG81eiahg4HZzrRDQ== | 2026-10-31 | Original Equipment |
| dyq+GEaHpdHKyeOq9lO7BQ== | 2026-10-31 | Original Equipment |
| 9S+l1WKDoXOiusNmx1JwvA== | 2026-10-31 | Original Equipment |
| +xKxsd4c6yS2W0p89Xjl+g== | 2026-10-30 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 13.56 MHz | 15C | CC | |||
| 2402-2480 MHz | 0.00673 | 15C | CC | ||
| 824.2-824.8 MHz | 2.9242 | 2.5 PM | 246KGXW | 22H | |
| 824.2-824.8 MHz | 0.6397 | 2.5 PM | 241KG7W | 22H | |
| 1852.4-1907.6 MHz | 0.4227 | 2.5 PM | 4M17F9W | 24E | |
| 1850.7-1909.3 MHz | 0.5808 | 2.5 PM | 1M08G7D | 24E | |
| 1851.5-1908.5 MHz | 0.5152 | 2.5 PM | 2M69W7D | 24E | |
| 1860-1900 MHz | 0.4764 | 2.5 PM | 18M0G7D | 24E | |
| 1860-1900 MHz | 0.4592 | 2.5 PM | 17W9W7D | 24E | |
| 1717.5-1747.5 MHz | 0.673 | 2.5 PM | 13M5G7D | 27 | |
| 1715-1750 MHz | 0.5957 | 2.5 PM | 8M99W7D | 27 | |
| 1720-1745 MHz | 0.547 | 2.5 PM | 18M0G7D | 27 | |
| 1720-1745 MHz | 0.5957 | 2.5 PM | 18M0W7D | 27 | |
| 824.7-848.3 MHz | 0.2917 | 2.5 PM | 1M08G7D | 22H | |
| 825.5-847.5 MHz | 0.2655 | 2.5 PM | 2M69W7D | 22H | |
| 829-844 MHz | 0.2851 | 2.5 PM | 8M99G7D | 22H | |
| 829-844 MHz | 0.2328 | 2.5 PM | 8M98W7D | 22H | |
| 2572.5-2617.5 MHz | 0.4909 | 2.5 PM | 4M49G7D | 27 | |
| 2577.5-2612.5 MHz | 0.4256 | 2.5 PM | 13M4W7D | 27 | |
| 2580-2610 MHz | 0.4624 | 2.5 PM | 17M9G7D | 27 | |
| 2580-2610 MHz | 0.3673 | 2.5 PM | 17M9W7D | 27 | |
| 2305-2395 MHz | 0.6668 | 2.5 PM | 9M02G7D | 27 | |
| 2310-2390 MHz | 0.6457 | 2.5 PM | 18M0G7D | 27 | |
| 2310-2390 MHz | 0.597 | 2.5 PM | 18M0W7D | 27 | |
| 2402-2480 MHz | 0.00203 | 15C | CC | ||
| 2412-2462 MHz | 0.03631 | 15C | CC | ||
| 5150-5250 MHz | 0.0022 | 15E | CC | ||
| 5725-5850 MHz | 0.00152 | 15E | CC |
Grants
TCB Grant - Application podQshx3+WOiTMNgy2ZTZw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 10/31/2026 Application Dated: 10/30/2026 |
| MediBioSense Ltd |
| MediBioSense Ltd, Beehive Office 3, Bawtry Hall, |
| South Parade, Doncaster, DN10 6JH, United Kingdom. |
| Doncaster, United Kingdom |
| Attention: Simon Beniston , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BWTH-IWT1 |
| Name of Grantee: | MediBioSense Ltd |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Infinity Watch |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 13.56 - 13.56 |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application kTbjlWG81eiahg4HZzrRDQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 10/31/2026 Application Dated: 11/02/2026 |
| MediBioSense Ltd |
| MediBioSense Ltd, Beehive Office 3, Bawtry Hall, |
| South Parade, Doncaster, DN10 6JH, United Kingdom. |
| Doncaster, United Kingdom |
| Attention: Simon Beniston , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BWTH-IWT1 |
| Name of Grantee: | MediBioSense Ltd |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Infinity Watch |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00673 |
| Output power listed is conducted power. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application dyq+GEaHpdHKyeOq9lO7BQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 10/31/2026 Application Dated: 10/30/2026 |
| MediBioSense Ltd |
| MediBioSense Ltd, Beehive Office 3, Bawtry Hall, |
| South Parade, Doncaster, DN10 6JH, United Kingdom. |
| Doncaster, United Kingdom |
| Attention: Simon Beniston , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BWTH-IWT1 |
| Name of Grantee: | MediBioSense Ltd |
| Equipment Class: | PCS Licensed Transmitter worn on body |
| Notes: | Infinity Watch |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 824.8 | 2.9242 | 2.5 PM | 246KGXW | |
| 22H | 824.2 - 824.8 | 0.6397 | 2.5 PM | 241KG7W | |
| 24E | 1852.4 - 1907.6 | 0.4227 | 2.5 PM | 4M17F9W | |
| 24E | 1850.7 - 1909.3 | 0.5808 | 2.5 PM | 1M08G7D | |
| 24E | 1851.5 - 1908.5 | 0.5152 | 2.5 PM | 2M69W7D | |
| 24E | 1860.0 - 1900.0 | 0.4764 | 2.5 PM | 18M0G7D | |
| 24E | 1860.0 - 1900.0 | 0.4592 | 2.5 PM | 17W9W7D | |
| 27 | 1717.5 - 1747.5 | 0.673 | 2.5 PM | 13M5G7D | |
| 27 | 1715.0 - 1750.0 | 0.5957 | 2.5 PM | 8M99W7D | |
| 27 | 1720.0 - 1745.0 | 0.547 | 2.5 PM | 18M0G7D | |
| 27 | 1720.0 - 1745.0 | 0.5957 | 2.5 PM | 18M0W7D | |
| 22H | 824.7 - 848.3 | 0.2917 | 2.5 PM | 1M08G7D | |
| 22H | 825.5 - 847.5 | 0.2655 | 2.5 PM | 2M69W7D | |
| 22H | 829.0 - 844.0 | 0.2851 | 2.5 PM | 8M99G7D | |
| 22H | 829.0 - 844.0 | 0.2328 | 2.5 PM | 8M98W7D | |
| 27 | 2572.5 - 2617.5 | 0.4909 | 2.5 PM | 4M49G7D | |
| 27 | 2577.5 - 2612.5 | 0.4256 | 2.5 PM | 13M4W7D | |
| 27 | 2580.0 - 2610.0 | 0.4624 | 2.5 PM | 17M9G7D | |
| 27 | 2580.0 - 2610.0 | 0.3673 | 2.5 PM | 17M9W7D | |
| 27 | 2305.0 - 2395.0 | 0.6668 | 2.5 PM | 9M02G7D | |
| 27 | 2310.0 - 2390.0 | 0.6457 | 2.5 PM | 18M0G7D | |
| 27 | 2310.0 - 2390.0 | 0.597 | 2.5 PM | 18M0W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the face of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for face accessory and simultaneous transmission use conditions is 0.41 W/kg and 0.80 W/kg respectively. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for extremity is 4.0 W/kg. The evaluation distance for extremity is 0 mm. The highest reported SAR for extremity and simultaneous transmission use conditions are 0.60 W/kg and 0.86 W/kg respectively. |
TCB Grant - Application 9S+l1WKDoXOiusNmx1JwvA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 10/31/2026 Application Dated: 10/30/2026 |
| MediBioSense Ltd |
| MediBioSense Ltd, Beehive Office 3, Bawtry Hall, |
| South Parade, Doncaster, DN10 6JH, United Kingdom. |
| Doncaster, United Kingdom |
| Attention: Simon Beniston , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BWTH-IWT1 |
| Name of Grantee: | MediBioSense Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Infinity Watch |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00203 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.03631 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the face of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for face accessory and simultaneous transmission use conditions is 0.11 W/kg and 0.80 W/kg respectively. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for extremity is 4.0 W/kg. The evaluation distance for extremity is 0 mm. The highest reported SAR for extremity and simultaneous transmission use conditions are 0.21 W/kg and 0.86 W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application +xKxsd4c6yS2W0p89Xjl+g==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 10/30/2026 Application Dated: 10/30/2026 |
| MediBioSense Ltd |
| MediBioSense Ltd, Beehive Office 3, Bawtry Hall, |
| South Parade, Doncaster, DN10 6JH, United Kingdom. |
| Doncaster, United Kingdom |
| Attention: Simon Beniston , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BWTH-IWT1 |
| Name of Grantee: | MediBioSense Ltd |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Infinity Watch |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5150.0 - 5250.0 | 0.0022 | ||
| CC | 15E | 5725.0 - 5850.0 | 0.00152 |
| Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the face of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for face accessory and simultaneous transmission use conditions is 0.39 W/kg and 0.80 W/kg respectively. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for extremity is 4.0 W/kg. The evaluation distance for extremity is 0 mm. The highest reported SAR for extremity and simultaneous transmission use conditions are 0.26 W/kg and 0.86 W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |