FCC ID 2AUXBDSGW-340

Medical Portable Gateway

by Hangzhou Roombanker Technology Co., Ltd.

Grantee Code: 2AUXB   Product Code: DSGW340
Latest application date: 2024-08-14

FCC ID Device Details

FCC ID2AUXBDSGW-340
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AUXB
Product CodeDSGW340
Applicant BusinessHangzhou Roombanker Technology Co., Ltd. 🇨🇳
Related Domains hzdusun.com
Equipment ClassMedical Portable Gateway
Test FirmJianYan Testing Group Shenzhen Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1860-1900 MHzOriginal Equipment2024-08-14
2402-2480 MHzOriginal Equipment2024-08-14

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2024-08-14PDF 596.8 KB
Internal photosInternal Photos2024-08-14PDF 2.2 MB
External photosExternal Photos2024-08-14PDF 760.3 KB
LabelID Label/Location Info2024-08-14PDF 409.1 KB
SAR test setupTest Setup Photos2024-08-14PDF 660.9 KB
Test setupTest Setup Photos2024-08-14PDF 249.3 KB
Test setupTest Setup Photos2024-08-14PDF 409.9 KB
Test setupTest Setup Photos2024-08-14PDF 331 KB
Antenna specificationTest Report2024-08-14PDF 1.3 MB
Antenna specificationTest Report2024-08-14PDF 1.2 MB
Antenna specificationTest Report2024-08-14PDF 1.2 MB
Modular test report part 1Test Report2024-08-14PDF 1.2 MB
Modular test report part 10Test Report2024-08-14PDF 3.3 MB
Modular test report part 11Test Report2024-08-14PDF 4.9 MB
Modular test report part 12Test Report2024-08-14PDF 3.6 MB
Modular test report part 2Test Report2024-08-14PDF 4.9 MB
Modular test report part 3Test Report2024-08-14PDF 3.6 MB
Modular test report part 4Test Report2024-08-14PDF 4.9 MB
Modular test report part 5Test Report2024-08-14PDF 3.6 MB
Modular test report part 6Test Report2024-08-14PDF 3.3 MB
Modular test report part 7Test Report2024-08-14PDF 3.4 MB
Modular test report part 8Test Report2024-08-14PDF 3.3 MB
Modular test report part 9Test Report2024-08-14PDF 3.4 MB
SAR test report part 1RF Exposure Info2024-08-14PDF 2.7 MB
SAR test report part 2RF Exposure Info2024-08-14PDF 3.1 MB
Test reportTest Report2024-08-14PDF 1.2 MB
Test reportTest Report2024-08-14PDF 1.4 MB
Test report BLE part 1Test Report2024-08-14PDF 2.3 MB
Test report BLE part 2Test Report2024-08-14PDF 1.2 MB
Test report BLE part 3Test Report2024-08-14PDF 1.3 MB
Test report BLE part 4Test Report2024-08-14PDF 1.3 MB
Test report BLE part 5Test Report2024-08-14PDF 1.3 MB
Test report WiFi part 1Test Report2024-08-14PDF 2.4 MB
Test report WiFi part 2Test Report2024-08-14PDF 5.1 MB
Covered equipment list attestationAttestation Statements2024-08-14PDF 70.1 KB
US agent attestationAttestation Statements2024-08-14PDF 22.7 KB
Agent letterCover Letter(s)2024-08-14PDF 112.8 KB
Agent letterCover Letter(s)2024-08-14PDF 111.3 KB
Confidentiality request letterCover Letter(s)2024-08-14PDF 84.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 158.3 KB
Schematics Metadata onlySchematicsPDF 693.3 KB
Operational Description Metadata onlyOperational DescriptionPDF 120.8 KB
Parts list Metadata onlyParts List/Tune Up InfoPDF 65.7 KB
Tune up Metadata onlyParts List/Tune Up InfoPDF 514.5 KB

Application Information

Application IDMYWIsB7OkXUMEPWXFbfgrA==
Final Action Date2024-08-14
Application PurposeOriginal Equipment
Applicant FRN0028932861
ModelDSGW-340
Frequency Range1860-1900 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionMedical Portable Gateway
Responsible PartyLin Su, qc03@hzdusun.com , 0571-86769027
Test FirmBruce Zhang, JianYan Testing Group Shenzhen Co., Ltd., bruce.zhang@ccis-cb.com , +86 (0) 755 23118282
TCB Emaildarial@compliancetesting.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power is EIRP and ERP for above and below 1 GHz, respectively. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are 1.19 W/kg and 1.20 W/kg, respectively. End-users must be informed of the operating requirements for satisfying RF exposure compliance. This device contains functions that are not operational in the U.S. Territories. This filing is only applicable for U.S. operations.

Applications

Application IDDatePurpose
MYWIsB7OkXUMEPWXFbfgrA==2024-08-14Original Equipment
5d52MdH9HuqzgVuaPOy2WQ==2024-08-14Original Equipment
1qgmDvkBASAvqDdgd5dTqQ==2024-08-14Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
15BCC
701.5-713.5 MHz0.01610.01ppm4M47G7D27
704-711 MHz0.01320.01ppm4M89W7D27
704-711 MHz0.01520.01ppm8M95G7D27
779.5-784.5 MHz0.05420.01ppm4M47G7D27
782 MHz0.05380.01ppm8M92G7D27
782 MHz0.04690.01ppm4M89W7D27
829-844 MHz0.07450.01ppm8M95G7D22H
829-844 MHz0.06470.01ppm4M89G7D22H
1717.5-1747.5 MHz0.27670.01ppm13M5G7D27
1720-1770 MHz0.29580.01ppm18M0G7D27
1720-1770 MHz0.24490.01ppm5M26G7D27
1720-1745 MHz0.27610.01ppm18M0G7D27
1720-1745 MHz0.22910.01ppm5M25W7D27
1860-1900 MHz0.2350.01ppm5M28W7D24E
2402-2480 MHz0.00119715CCC
2412-2462 MHz0.01901115CCC

Grants

TCB Grant - Application MYWIsB7OkXUMEPWXFbfgrA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Compliance Testing, LLC
1724 S. Nevada Way
Mesa, AZ 85204
Date of Grant: 08/14/2024

Application Dated: 08/11/2024
Hangzhou Roombanker Technology Co., Ltd.
A#801 Wantong center,
Hangzhou,
China
 
Attention: Lin Su

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUXBDSGW-340
Name of Grantee:  Hangzhou Roombanker Technology Co., Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: Medical Portable Gateway
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1860.0  -  1900.0 0.2891 0.01  PM 18M0G7D
24E 1860.0  -  1900.0 0.235 0.01  PM 5M28W7D
27 1717.5  -  1747.5 0.2767 0.01  PM 13M5G7D
27 1720.0  -  1745.0 0.2761 0.01  PM 18M0G7D
27 1720.0  -  1745.0 0.2291 0.01  PM 5M25W7D
22H 829.0  -  844.0 0.0745 0.01  PM 8M95G7D
22H 829.0  -  844.0 0.0647 0.01  PM 4M89G7D
27 701.5  -  713.5 0.0161 0.01  PM 4M47G7D
27 704.0  -  711.0 0.0152 0.01  PM 8M95G7D
27 704.0  -  711.0 0.0132 0.01  PM 4M89W7D
27 779.5  -  784.5 0.0542 0.01  PM 4M47G7D
27 782.0  -  782.0 0.0538 0.01  PM 8M92G7D
27 782.0  -  782.0 0.0469 0.01  PM 4M89W7D
27 1720.0  -  1770.0 0.2958 0.01  PM 18M0G7D
27 1720.0  -  1770.0 0.2449 0.01  PM 5M26G7D

Output Power is EIRP and ERP for above and below 1 GHz, respectively. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are 1.19 W/kg and 1.20 W/kg, respectively. End-users must be informed of the operating requirements for satisfying RF exposure compliance. This device contains functions that are not operational in the U.S. Territories. This filing is only applicable for U.S. operations.

EAS Grant - Application MYWIsB7OkXUMEPWXFbfgrA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hangzhou Roombanker Technology Co., Ltd.
A#801 Wantong center,
Hangzhou,
China
  Date of Grant: 08/14/2024

Application Dated: 08/11/2024
 
Attention: Lin Su

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUXBDSGW-340
Name of Grantee:  Hangzhou Roombanker Technology Co., Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: Medical Portable Gateway
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1860.0  -  1900.0 0.2891 0.01  PM 18M0G7D
24E 1860.0  -  1900.0 0.235 0.01  PM 5M28W7D
27 1717.5  -  1747.5 0.2767 0.01  PM 13M5G7D
27 1720.0  -  1745.0 0.2761 0.01  PM 18M0G7D
27 1720.0  -  1745.0 0.2291 0.01  PM 5M25W7D
22H 829.0  -  844.0 0.0745 0.01  PM 8M95G7D
22H 829.0  -  844.0 0.0647 0.01  PM 4M89G7D
27 701.5  -  713.5 0.0161 0.01  PM 4M47G7D
27 704.0  -  711.0 0.0152 0.01  PM 8M95G7D
27 704.0  -  711.0 0.0132 0.01  PM 4M89W7D
27 779.5  -  784.5 0.0542 0.01  PM 4M47G7D
27 782.0  -  782.0 0.0538 0.01  PM 8M92G7D
27 782.0  -  782.0 0.0469 0.01  PM 4M89W7D
27 1720.0  -  1770.0 0.2958 0.01  PM 18M0G7D
27 1720.0  -  1770.0 0.2449 0.01  PM 5M26G7D

Output Power is EIRP and ERP for above and below 1 GHz, respectively. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are 1.19 W/kg and 1.20 W/kg, respectively. End-users must be informed of the operating requirements for satisfying RF exposure compliance. This device contains functions that are not operational in the U.S. Territories. This filing is only applicable for U.S. operations.



TCB Grant - Application 5d52MdH9HuqzgVuaPOy2WQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Compliance Testing, LLC
1724 S. Nevada Way
Mesa, AZ 85204
Date of Grant: 08/14/2024

Application Dated: 08/11/2024
Hangzhou Roombanker Technology Co., Ltd.
A#801 Wantong center,
Hangzhou,
China
 
Attention: Lin Su

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUXBDSGW-340
Name of Grantee:  Hangzhou Roombanker Technology Co., Ltd.
Equipment Class: Part 15 Class B Digital Device
Notes: Medical Portable Gateway
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 5d52MdH9HuqzgVuaPOy2WQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hangzhou Roombanker Technology Co., Ltd.
A#801 Wantong center,
Hangzhou,
China
  Date of Grant: 08/14/2024

Application Dated: 08/11/2024
 
Attention: Lin Su

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUXBDSGW-340
Name of Grantee:  Hangzhou Roombanker Technology Co., Ltd.
Equipment Class: Part 15 Class B Digital Device
Notes: Medical Portable Gateway
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 1qgmDvkBASAvqDdgd5dTqQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Compliance Testing, LLC
1724 S. Nevada Way
Mesa, AZ 85204
Date of Grant: 08/14/2024

Application Dated: 08/11/2024
Hangzhou Roombanker Technology Co., Ltd.
A#801 Wantong center,
Hangzhou,
China
 
Attention: Lin Su

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUXBDSGW-340
Name of Grantee:  Hangzhou Roombanker Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Medical Portable Gateway
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.001197  
CC 15C 2412.0  -  2462.0 0.019011  

Output power listed is conducted. This device has 20 MHz and 40 MHz bandwidth mode. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are < 0.10 W/kg and 1.20 W/kg, respectively. End-users must be informed of the operating requirements for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 1qgmDvkBASAvqDdgd5dTqQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hangzhou Roombanker Technology Co., Ltd.
A#801 Wantong center,
Hangzhou,
China
  Date of Grant: 08/14/2024

Application Dated: 08/11/2024
 
Attention: Lin Su

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AUXBDSGW-340
Name of Grantee:  Hangzhou Roombanker Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Medical Portable Gateway
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.001197  
CC 15C 2412.0  -  2462.0 0.019011  

Output power listed is conducted. This device has 20 MHz and 40 MHz bandwidth mode. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are < 0.10 W/kg and 1.20 W/kg, respectively. End-users must be informed of the operating requirements for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: