FCC ID ALH32263110

22, 74, 90, 95

by Kenwood USA Corporation

Grantee Code: ALH   Product Code: 32263110
Latest application date: 2001-10-30

FCC ID Device Details

FCC IDALH32263110
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeALH
Product Code32263110
Applicant BusinessKenwood USA Corporation 🇺🇸
Related Domains us.jvckenwood.com mflom.com
Equipment Class22, 74, 90, 95
Test FirmM. Flom Associates, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
450-490 MHzOriginal Equipment2001-10-30

Exhibits

DocumentTypeAvailableFile
Instruction ManualUsers Manual2001-10-30PDF 88.9 KB
Confirmation of Internal Photos UploadedBlock Diagram2001-10-30PDF 67.5 KB
Internal PhotosInternal Photos2001-10-30PDF 1 MB
External PhotosExternal Photos2001-10-30PDF 2.1 MB
LabelID Label/Location Info2001-10-30PDF 250.4 KB
Label LocationID Label/Location Info2001-10-30PDF 570.7 KB
Block DiagramBlock Diagram2001-10-30PDF 420.2 KB
SchematicsSchematics2001-10-30PDF 1.1 MB
Circuit DescriptionOperational Description2001-10-30PDF 14.7 KB
Test ReportTest Report2001-10-30PDF 248.3 KB
Part 90 AttestationAttestation Statements2001-10-30PDF 9.2 KB
Agent AuthorizationCover Letter(s)2001-10-30PDF 9.4 KB
Copy of Change of Address NotificationCover Letter(s)2001-10-30PDF 45.9 KB
Active DevicesParts List/Tune Up Info2001-10-30PDF 9.9 KB
Parts ListParts List/Tune Up Info2001-10-30PDF 7.3 KB
Radio Frequency Safety InformationRF Exposure Info2001-10-30PDF 58.4 KB
SAR ReportRF Exposure Info2001-10-30PDF 2.4 MB
Tuning ProcedureParts List/Tune Up Info2001-10-30PDF 11.9 KB

Application Information

Application IDro2GVptn09PeO4oLX8hHRg==
Final Action Date2001-10-30
Application PurposeOriginal Equipment
Applicant FRN0004356960
Model32263110
Frequency Range450-490 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device Description22, 74, 90, 95
Responsible PartyAngelina Seay, Regulatory Support Engineer, aseay@us.jvckenwood.com , 6784744701
AgentMorton Morton Morton, M. Flom Associates, Inc., general@mflom.com , 480 926 3100
Technical ContactMorton Flom, M. Flom Associates, Inc, general@mflom.com , 480 926 3100
Non-Technical ContactMorton Flom, M. Flom Associates, Inc., general@mflom.com , 480 926 3100
Test FirmMorton Flom, M. Flom Associates, Inc., info@mflom.com , 480-926-3100
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is at the antenna terminal on the device. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations with a specific antenna, and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50% and SAR compliance for body-worn operating configurations is limited to the specific belt-clip tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values at 50% duty factor are - Head: 4.24 W/kg; Body-worn: 4.67 W/kg.

Applications

Application IDDatePurpose
ro2GVptn09PeO4oLX8hHRg==2001-10-30Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
450-490 MHz12.5ppm11K0F3E22, 74, 90.210, 95
450-490 MHz4.52.5ppm11K0F3E22, 74, 90.210, 95BF
450-490 MHz12.5ppm16K0F3E22, 74, 90, 95
450-490 MHz4.52.5ppm16K0F3E22, 74, 90, 95BF

Grants

TCB Grant - Application ro2GVptn09PeO4oLX8hHRg==

This application does not exist.

EAS Grant - Application ro2GVptn09PeO4oLX8hHRg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Kenwood USA Corporation
5000 Research Ct Suite 700
Suwanee, GA 30024
United States
  Date of Grant: 10/30/2001

Application Dated: 09/10/2001
 
Attention: Angelina Seay , Regulatory Support Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ALH32263110
Name of Grantee:  Kenwood USA Corporation
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: 22, 74, 90, 95
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22, 74, 95, 90.210 450.0  -  490.0 1.0 2.5  PM 11K0F3E
BF 22, 74, 95, 90.210 450.0  -  490.0 4.5 2.5  PM 11K0F3E
22, 74, 90, 95 450.0  -  490.0 1.0 2.5  PM 16K0F3E
BF 22, 74, 90, 95 450.0  -  490.0 4.5 2.5  PM 16K0F3E

Power output listed is at the antenna terminal on the device. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations with a specific antenna, and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50% and SAR compliance for body-worn operating configurations is limited to the specific belt-clip tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values at 50% duty factor are - Head: 4.24 W/kg; Body-worn: 4.67 W/kg.


BF: The output power is continuously variable from the value listed in this entry to 20%-25% of the value listed.

Mail To:
Morton Flom, P. Eng., President
M. Flom Associates, Inc.
3356 N. San Marcos Pl., Suite 107
Chandler, AZ 85225-7176