FCC ID ALH32263130
UHF Hand held to face
by Kenwood USA Corporation
Grantee Code: ALH Product Code: 32263130
Latest application date: 2002-03-14
FCC ID Device Details
| FCC ID | ALH32263130 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | ALH |
| Product Code | 32263130 |
| Applicant Business | Kenwood USA Corporation 🇺🇸 |
| Related Domains | |
| Equipment Class | UHF Hand held to face |
| Test Firm | M. Flom Associates, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 400-430 MHz | Original Equipment | 2002-03-14 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Manual | Users Manual | 2002-03-14 | PDF 88.7 KB |
| RF Exposure Info to be placed in manual | RF Exposure Info | 2002-03-14 | PDF 3.5 KB |
| Internal Photos | Internal Photos | 2002-03-14 | PDF 35.6 KB |
| External Photos | External Photos | 2002-03-14 | PDF 67 KB |
| Label | ID Label/Location Info | 2002-03-14 | PDF 246.2 KB |
| Block Diagram | Block Diagram | 2002-03-14 | PDF 50.7 KB |
| Schematic | Schematics | 2002-03-14 | PDF 334.9 KB |
| Circuit Description | Operational Description | 2002-03-14 | PDF 19.8 KB |
| Specifications | Operational Description | 2002-03-14 | PDF 8.8 KB |
| Test Report | Test Report | 2002-03-14 | PDF 497.7 KB |
| Agent Authorization | Cover Letter(s) | 2002-03-14 | PDF 9.4 KB |
| Part 90 Cover Letter | Cover Letter(s) | 2002-03-14 | PDF 9.2 KB |
| Parts List | Parts List/Tune Up Info | 2002-03-14 | PDF 51.7 KB |
| Photo showing RF Exposure label | RF Exposure Info | 2002-03-14 | PDF 505.6 KB |
| SAR Report Part 1 | RF Exposure Info | 2002-03-14 | PDF 3.8 MB |
| SAR Report Part 2 | RF Exposure Info | 2002-03-14 | PDF 495.1 KB |
| Tuning Procedure | Parts List/Tune Up Info | 2002-03-14 | PDF 12.1 KB |
Application Information
| Application ID | G1jWRdcPMuYkmx8HhvlC5w== |
|---|---|
| Final Action Date | 2002-03-14 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0004356960 |
| Model | 32263130 |
| Frequency Range | 400-430 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | UHF Hand held to face |
| Responsible Party | Angelina Seay, Regulatory Support Engineer, aseay@us.jvckenwood.com |
| Agent | Morton Morton Morton, M. Flom Associates, Inc., general@mflom.com |
| Technical Contact | Morton Flom, M. Flom Associates, Inc., general@mflom.com |
| Non-Technical Contact | Morton Flom, M. Flom Associates, Inc., general@mflom.com |
| Test Firm | Morton Flom, M. Flom Associates, Inc., info@mflom.com |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output is at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the antenna tested for this filing in Push-to-Talk and body-worn configurations. The duty factor is not to exceed 50%. Body-worn SAR compliance is limited to the specific belt-clip and speaker/microphone configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 3.24 W/kg; Body-worn: 4.13 W/kg at 50% duty factor. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| G1jWRdcPMuYkmx8HhvlC5w== | 2002-03-14 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application G1jWRdcPMuYkmx8HhvlC5w==
This application does not exist.
EAS Grant - Application G1jWRdcPMuYkmx8HhvlC5w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Kenwood USA Corporation 5000 Research Ct Suite 700 Suwanee, GA 30024 United States |
Date of Grant: 03/14/2002 Application Dated: 12/14/2001 |
| Attention: Angelina Seay , Regulatory Support Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ALH32263130 |
| Name of Grantee: | Kenwood USA Corporation |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | UHF Hand held to face |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BF | 90.210 | 400.0 - 430.0 | 1.0 | 2.5 PM | 11K0F3E |
| BF | 90 | 400.0 - 430.0 | 1.0 | 2.5 PM | 16K0F3E |
| BF | 90.210 | 400.0 - 430.0 | 4.1 | 2.5 PM | 11K0F3E |
| BF | 90 | 400.0 - 430.0 | 4.1 | 2.5 PM | 16K0F3E |
| Power is conducted. |
| Part 90.210 is single channel mode. |
| Output is at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the antenna tested for this filing in Push-to-Talk and body-worn configurations. The duty factor is not to exceed 50%. Body-worn SAR compliance is limited to the specific belt-clip and speaker/microphone configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 3.24 W/kg; Body-worn: 4.13 W/kg at 50% duty factor. |
| BF: | The output power is continuously variable from the value listed in this entry to 20%-25% of the value listed. |
| Mail To: |
| Morton Flom, President |
| M. Flom Associates, Inc. |
| 3356 N. San Marcos Place, Suite 107 |
| Chandler, AZ 85225 |