FCC ID ALH36913210
VHF/FM Handheld Transceiver
by Kenwood USA Corporation
Grantee Code: ALH Product Code: 36913210
Latest application date: 2004-03-01
FCC ID Device Details
| FCC ID | ALH36913210 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | ALH |
| Product Code | 36913210 |
| Applicant Business | Kenwood USA Corporation 🇺🇸 |
| Related Domains | |
| Equipment Class | VHF/FM Handheld Transceiver |
| Test Firm | M. Flom Associates, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 136-174 MHz | Original Equipment | 2004-03-01 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Instruction Manual | Users Manual | 2004-03-01 | PDF 920.2 KB |
| Instruction Manual 2 | Users Manual | 2004-03-01 | PDF 16.4 KB |
| Internal Photos | Internal Photos | 2004-03-01 | PDF 45.5 KB |
| External Photos | External Photos | 2004-03-01 | PDF 36.4 KB |
| Label | ID Label/Location Info | 2004-03-01 | PDF 13.9 KB |
| Label Location | ID Label/Location Info | 2004-03-01 | PDF 39.6 KB |
| Test Report | Test Report | 2004-03-01 | PDF 1.4 MB |
| Part 90 Attestation | Attestation Statements | 2004-03-01 | PDF 70.7 KB |
| Confidentiality Request | Cover Letter(s) | 2004-03-01 | PDF 84.6 KB |
| MFA Response to Correspondence 26424 | Cover Letter(s) | 2004-03-01 | PDF 59.6 KB |
| Response to Correspondence 26435 | Cover Letter(s) | 2004-03-01 | PDF 55.6 KB |
| SAR Report | RF Exposure Info | 2004-03-01 | PDF 2.6 MB |
| Block Diagram Metadata only | Block Diagram | PDF 29.3 KB | |
| Schematic Diagram Metadata only | Schematics | PDF 177.5 KB | |
| Circuit Description Metadata only | Operational Description | PDF 15.5 KB | |
| Active Devices Metadata only | Parts List/Tune Up Info | PDF 9.1 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 5.6 KB | |
| Tuning Procedure Metadata only | Parts List/Tune Up Info | PDF 11.2 KB |
Application Information
| Application ID | 8P8EjmiUv4H13SvzlCBetw== |
|---|---|
| Final Action Date | 2004-03-01 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0004356960 |
| Model | 36913210 |
| Frequency Range | 136-174 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | VHF/FM Handheld Transceiver |
| Responsible Party | Angelina Seay, Regulatory Support Engineer, aseay@us.jvckenwood.com |
| Agent | Morton Morton Morton, M. Flom Associates, Inc., general@mflom.com |
| Technical Contact | Morton Flom, M. Flom Associates, Inc., general@mflom.com |
| Non-Technical Contact | Morton Flom, M. Flom Associates, Inc., general@mflom.com |
| Test Firm | Morton Flom, M. Flom Associates, Inc., info@mflom.com |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output is at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the three antennas tested for this filing in Push-to-Talk and body-worn configurations. Body-worn SAR compliance is limited to the specific belt-clip and speaker/microphone configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 1.57 W/kg; Body-worn: 1.77 W/kg accounting for a 50% duty cycle. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 8P8EjmiUv4H13SvzlCBetw== | 2004-03-01 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application 8P8EjmiUv4H13SvzlCBetw==
This application does not exist.
EAS Grant - Application 8P8EjmiUv4H13SvzlCBetw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Kenwood USA Corporation 5000 Research Ct Suite 700 Suwanee, GA 30024 United States |
Date of Grant: 03/01/2004 Application Dated: 01/09/2004 |
| Attention: Angelina Seay , Regulatory Support Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ALH36913210 |
| Name of Grantee: | Kenwood USA Corporation |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | VHF/FM Handheld Transceiver |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BE | 22, 74, 90 | 136.0 - 174.0 | 1.0 | 2.5 PM | 16K0F3E |
| BE | 22, 74, 90 | 136.0 - 174.0 | 5.0 | 2.5 PM | 16K0F3E |
| BE | 22, 74, 90.210 | 136.0 - 174.0 | 1.0 | 2.5 PM | 11K0F3E |
| BE | 22, 74, 90.210 | 136.0 - 174.0 | 5.0 | 2.5 PM | 11K0F3E |
| Output is at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the three antennas tested for this filing in Push-to-Talk and body-worn configurations. Body-worn SAR compliance is limited to the specific belt-clip and speaker/microphone configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 1.57 W/kg; Body-worn: 1.77 W/kg accounting for a 50% duty cycle. |
| BE: | The output power is continuously variable from the value listed in this entry to 15%-20% of the value listed. |
| Mail To: |
| Morton Flom, P. Eng., President |
| M. Flom Associates, Inc. |
| 3356 N. San Marcos Pl., Suite 107 |
| Chandler, AZ 85225-7176 |