PBQ5DK QI 5W Charging Dock 5000mah RF Exposure Info SZEM180200132103 MPE RPT Scosche Industries Inc

Scosche Industries Inc QI 5W Charging Dock 5000mah

FCC ID Filing: IKQPBQ5DK
Purchase on Amazon: QI 5W Charging Dock 5000mah

Trouble Viewing? See the or view the HTML Version or PDF in frame
Page 1 of PBQ5DK QI 5W Charging Dock 5000mah RF Exposure Info SZEM180200132103 MPE RPT Scosche Industries Inc
Page 2 of PBQ5DK QI 5W Charging Dock 5000mah RF Exposure Info SZEM180200132103 MPE RPT Scosche Industries Inc
Page 3 of PBQ5DK QI 5W Charging Dock 5000mah RF Exposure Info SZEM180200132103 MPE RPT Scosche Industries Inc
Page 4 of PBQ5DK QI 5W Charging Dock 5000mah RF Exposure Info SZEM180200132103 MPE RPT Scosche Industries Inc
Page 5 of PBQ5DK QI 5W Charging Dock 5000mah RF Exposure Info SZEM180200132103 MPE RPT Scosche Industries Inc
Page 6 of PBQ5DK QI 5W Charging Dock 5000mah RF Exposure Info SZEM180200132103 MPE RPT Scosche Industries Inc
Page 7 of PBQ5DK QI 5W Charging Dock 5000mah RF Exposure Info SZEM180200132103 MPE RPT Scosche Industries Inc
Page 8 of PBQ5DK QI 5W Charging Dock 5000mah RF Exposure Info SZEM180200132103 MPE RPT Scosche Industries Inc
Page 9 of PBQ5DK QI 5W Charging Dock 5000mah RF Exposure Info SZEM180200132103 MPE RPT Scosche Industries Inc
Page 10 of PBQ5DK QI 5W Charging Dock 5000mah RF Exposure Info SZEM180200132103 MPE RPT Scosche Industries Inc

SGS-CSTC Standards Technical Services Co., Ltd.
Shenzhen Branch
No. 1 Workshop, M-10, Middle Section, Science & Technology Park,
Shenzhen, China 518057
Telephone:
Fax:
Email:
Report No.: SZEM180200132103
Page:
1 of 10
+86 (0) 755 2601 2053
+86 (0) 755 2671 0594
ee.shenzhen@sgs.com
Human Exposure Report
0000000000000000000
Application No.:
SZEM1802001321CR
Applicant/ Manufacturer:
SCOSCHE Industries Inc.
Address of
Manufacturer:
1550 Pacific Avenue, Oxnard, California, 93033, United States
Applicant/
Factory:
SCOSCHE Industries Inc.
Address of Factory:
1550 Pacific Avenue, Oxnard, California, 93033, United States
Equipment Under Test (EUT):
EUT Name:
QI 5W Charging Dock 5000mah
Model No.:
Trade Mark:
PBQ5DK, PBQ5DKSG-SP, PBQ5DKWT-SP ♣
Please refer to section 3.2 of this report which indicates which model was
actually tested and which were electrically identical.
SCOSCHE
FCC ID:
IKQPBQ5DK
Standards:
47 CFR PART 1, Subpart I, Section 1.1310
Date of Receipt:
2018-02-09
Date of Test:
2018-02-27 to 2018-03-02
Date of Issue:
2018-03-06
♣
Test Result :
Pass*
* In the configuration tested, the EUT complied with the standards specified above.
Keny Xu
EMC Laboratory Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system
complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International Electrical
Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International Electrical
Approvals in writing.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
SGS-CSTC Standards Technical Services Co., Ltd.
Shenzhen Branch
Report No.: SZEM180200132103
Page:
2 of 10
Contents
Page
COVER PAGE ..................................................................................................................................... 1
CONTENTS ...................................................................................................................................................... 2
GENERAL INFORMATION ............................................................................................................................. 3
3.1
3.2
3.3
3.4
3.5
3.6
DETAILS OF E.U.T. .......................................................................................................................................... 3
DESCRIPTION OF SUPPORT UNITS ...................................................................................................................... 3
TEST LOCATION ............................................................................................................................................... 4
TEST FACILITY................................................................................................................................................. 4
DEVIATION FROM STANDARDS .......................................................................................................................... 4
ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................................ 4
EQUIPMENTS USED DURING TEST ........................................................................................................... 5
TEST RESULTS............................................................................................................................................... 6
5.1 RF EXPOSURE TEST .......................................................................................................................................... 6
5.1.1 E.U.T. Operation ................................................................................................................................. 6
Operating Environment:.................................................................................................................................... 6
EUT Operation: ................................................................................................................................................. 6
5.1.2 Measurement Data ......................................................................................................................... 7-10
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shenzhen Branch
Report No.: SZEM180200132103
Page:
3 of 10
General Information
3.1 Details of E.U.T.
Power supply:
Input: DC 5V/2A; DC 9V/1.67A from TYPE C port or docking station
Wireless output: 5W, 10W;
USB output: DC 5V, 2.4A
Power supply information,
MODEL: DBS15Q
INPUT: AC 100-240V, 50/60Hz
OUTPUT: DC 5V/2A; DC 9V/2A; DC 12V/1.5A
Cable:
USB lind attached in Docking station: 100cm, unshielded
TYPE C USB charging line: 100cm, unshielded
Operation frequency:
111.2-183.3 kHz
Modulation type:
Load modulation
Antenna type:
Inductive Loop Coil Antenna
Remark:
Tests were conducted in both loads and the worst case (DC 9V/1.1A) is
reported only.
3.2 Description of Support Units
The EUT has been tested with associated equipment below.
Description
Manufacturer
Model No.
Serial No.
cement load
provided by client
DC 5V/1A
N/A
Galaxy S7 edge
N/A
mobile phone
Samsung(provided by
client)
Remark:
Model No.: PBQ5DK, PBQ5DKSG-SP, PBQ5DKWT-SP
Only the model PBQ5DK was tested, since the electrical circuit design, layout, components used,
internal wiring and functions were identical for all the above models, with only difference on housing
color.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shenzhen Branch
Report No.: SZEM180200132103
Page:
4 of 10
3.3 Test Location
All tests were performed at:
SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab,
No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong,China
518057.
Tel: +86 755 2601 2053
Fax: +86 755 2671 0594
No tests were sub-contracted.
3.4 Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
• CNAS (No. CNAS L2929)
CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
Laboratories) for the competence in the field of testing.
• A2LA (Certificate No. 3816.01)
SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
• VCCI
The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
been registered in accordance with the Regulations for Voluntary Control Measures with Registration
No.: G-20026, R-14188, C-12383 and T-11153 respectively.
• FCC –Designation Number: CN1178
SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
as an accredited testing laboratory.
Designation Number: CN1178. Test Firm Registration Number: 406779.
• Industry Canada (IC)
Two 3m Semi-anechoic chambers and the 10m Semi-anechoic chamber of SGS-CSTC Standards
Technical Services Co., Ltd. Shenzhen Branch EMC Lab have been registered by Certification and
Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 4620C-1,
4620C-2, 4620C-3.
3.5 Deviation from Standards
None.
3.6 Abnormalities from Standard Conditions
None.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shenzhen Branch
Report No.: SZEM180200132103
Page:
5 of 10
Equipments Used during Test
Item
Test Equipment
Manufacturer
Model No.
Inventory
No.
Cal. Due date
3m Semi-Anechoic
Chamber
ETS-LINDGREN
N/A
SEL0017
2018-06-10
Electric Field Meter
Schaffner
EMC20
EMC068
2018-03-27
(yyyy-mm-dd)
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shenzhen Branch
Report No.: SZEM180200132103
Page:
6 of 10
Test Results
5.1 RF Exposure test
Test Requirement:
47 CFR PART 1, Subpart I, Section 1.1310
Measurement Distance:
10cm /8cm /6cm/ 0cm
Limit:
Frequency range Electric field strength Magnetic field strength Power density Averaging time
(MHz)
(V/m)
(A/m)
(mW/cm2)
(minutes)
(A) Limits for Occupational/Controlled Exposures
0.3-3.0
614
1.63
*(100)
3.0-30
1842/f
4.89/f
*(900/f 2)
30-300
61.4
0.163
1.0
300-1500
f/300
1500-100,000
(B) Limits for General Population/Uncontrolled Exposure
0.3-1.34
614
1.63
*(100)
30
1.34-30
824/f
2.19/f
*(180/f 2)
30
30-300
27.5
0.073
0.2
30
300-1500
f/1500
30
1500-100,000
1.0
30
F=frequency in MHz
*=Plane-wave equivalent power density
RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC
rules. The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits
for 150kHz:614V/m,1.63A/m).
5.1.1
E.U.T. Operation
Operating Environment:
Temperature:
24.0 °C
Humidity:
52 % RH
Atmospheric Pressure: 1015 mbar
EUT Operation:
This device has been tested the worst status of full load and the device has been tested with
mobile phone at zero charge, intermediate charge, and full charge.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shenzhen Branch
Report No.: SZEM180200132103
Page:
7 of 10
5.1.2
Measurement Data
1: Output Voltage=DC 9V; The max output power =10W;Calculation of resistor value=8.2Ω
Ω
Electric Field Emissions
Operation
frequency
Test Distance
Test Position
Probe Measure
Result (V/m)
30% Limit
Side 1
4.51
184.2
Side 2
4.44
184.2
Side 3
5.21
184.2
Side 4
4.52
184.2
Top
6.39
184.2
Side 1
4.56
184.2
Side 2
4.59
184.2
Side 3
5.32
184.2
Side 4
4.89
184.2
Top
6.54
184.2
Side 1
4.89
184.2
Side 2
4.76
184.2
Side 3
5.54
184.2
Side 4
5.12
184.2
Top
6.52
184.2
Side 1
5.03
184.2
Side 2
5.00
184.2
Side 3
5.79
184.2
Side 4
5.24
184.2
Top
6.73
184.2
(cm)
10
167.3 kHz
(V/m)
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shenzhen Branch
Report No.: SZEM180200132103
Page:
8 of 10
Magnetic Field Emissions
Operation
frequency
Test Distance
Test Position
Probe Measure
Result (A/m)
30% Limit
Side 1
0.0743
0.489
Side 2
0.0876
0.489
Side 3
0.0852
0.489
Side 4
0.0842
0.489
Top
0.1426
0.489
Side 1
0.0751
0.489
Side 2
0.0878
0.489
Side 3
0.0865
0.489
Side 4
0.0869
0.489
Top
0.1452
0.489
Side 1
0.0769
0.489
Side 2
0.0874
0.489
Side 3
0.0883
0.489
Side 4
0.0891
0.489
Top
0.1478
0.489
Side 1
0.0809
0.489
Side 2
0.0913
0.489
Side 3
0.0900
0.489
Side 4
0.0923
0.489
Top
0.1502
0.489
(cm)
10
167.3 kHz
(A/m)
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shenzhen Branch
Report No.: SZEM180200132103
Page:
9 of 10
4:Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
Operation
frequency
Test
Distance
Test
167.3 kHz
30%Limit
Position
zero
charge
intermediate
charge
full
charge
(V/m)
Side 1
4.68
4.86
3.65
184.2
Side 2
4.37
4.88
3.30
184.2
Side 3
4.30
5.64
4.50
184.2
Side 4
3.98
4.28
3.44
184.2
Top
5.73
5.51
5.21
184.2
Side 1
4.65
4.95
4.46
184.2
Side 2
4.59
5.05
4.81
184.2
Side 3
4.72
5.24
4.98
184.2
Side 4
4.21
4.43
4.59
184.2
Top
5.98
5.68
5.37
184.2
Side 1
4.78
5.02
4.75
184.2
Side 2
4.52
5.13
4.97
184.2
Side 3
4.89
5.35
5.12
184.2
Side 4
4.62
4.67
4.78
184.2
Top
5.97
5.86
5.51
184.2
Side 1
4.80
5.34
4.89
184.2
Side 2
4.76
5.54
5.14
184.2
Side 3
5.02
5.61
5.26
184.2
Side 4
4.89
5.01
5.09
184.2
Top
6.23
6.26
6.09
184.2
(cm)
10
Probe Measure Result(V/m)
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
SGS-CSTC Standards Technical Services Co., Ltd.
Shenzhen Branch
Report No.: SZEM180200132103
Page:
10 of 10
Magnetic Field Emissions
Operation
frequency
Test
Distance
Test
167.3 kHz
30%Limit
Position
zero
charge
intermediate
charge
full
charge
(A/m)
Side 1
0.0214
0.0170
0.0189
0.489
Side 2
0.0222
0.0166
0.0157
0.489
Side 3
0.0268
0.0153
0.0171
0.489
Side 4
0.0154
0.0148
0.0187
0.489
Top
0.0340
0.0242
0.0334
0.489
Side 1
0.0223
0.0231
0.0237
0.489
Side 2
0.0234
0.0243
0.0258
0.489
Side 3
0.0271
0.0278
0.0281
0.489
Side 4
0.0228
0.0236
0.0230
0.489
Top
0.0351
0.0358
0.0349
0.489
Side 1
0.0237
0.0241
0.0248
0.489
Side 2
0.0241
0.0257
0.0251
0.489
Side 3
0.0285
0.0294
0.0289
0.489
Side 4
0.0248
0.0252
0.0259
0.489
Top
0.0368
0.0375
0.0370
0.489
Side 1
0.0264
0.0274
0.0271
0.489
Side 2
0.0273
0.0280
0.0275
0.489
Side 3
0.0295
0.0293
0.0291
0.489
Side 4
0.0287
0.0281
0.0293
0.489
Top
0.0385
0.0389
0.0380
0.489
(cm)
10
Probe Measure Result(A/m)
- End of the Report -
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only
Download: PBQ5DK QI 5W Charging Dock 5000mah RF Exposure Info SZEM180200132103 MPE RPT Scosche Industries Inc
Mirror Download [FCC.gov]PBQ5DK QI 5W Charging Dock 5000mah RF Exposure Info SZEM180200132103 MPE RPT Scosche Industries Inc
Document ID3843828
Application IDxrHHEHg/umGDpCaBmAMrOQ==
Document DescriptionRF Exposure Info
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize11.88kB (148545 bits)
Date Submitted2018-05-08 00:00:00
Date Available2018-05-08 00:00:00
Creation Date2018-05-03 13:48:02
Producing SoftwareGPL Ghostscript 8.64
Document Lastmod2018-05-03 05:48:03
Document TitleSZEM180200132103 MPE RPT
Document CreatorPScript5.dll Version 5.2.2
Document Author: kate_bian

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Print high-res
Page Count                      : 10
Create Date                     : 2018:05:03 13:48:02+08:00
Title                           : Microsoft Word - SZEM180200132103 MPE RPT.doc
Producer                        : GPL Ghostscript 8.64
Author                          : kate_bian
Creator                         : PScript5.dll Version 5.2.2
Modify Date                     : 2018:05:03 05:48:03Z
EXIF Metadata provided by EXIF.tools

Facebook Twitter Google+ RSS © FCCID.io 2018