FCC ID K66VX-210U

Transmitter held to face

by Yaesu Musen Co., Ltd.

Grantee Code: K66   Product Code: VX210U
Latest application date: 2001-09-26

FCC ID Device Details

FCC IDK66VX-210U
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeK66
Product CodeVX210U
Applicant BusinessYaesu Musen Co., Ltd. 🇯🇵
Related Domains yaesu.com mflom.com
Equipment ClassTransmitter held to face
Test FirmM. Flom Associates, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
450-490 MHzClass II permissive change or modification of presently authorized equipment2001-09-26
450-485 MHzOriginal Equipment1999-12-03

Exhibits

DocumentTypeAvailableFile
RF Exposure Manual StatementUsers Manual2001-09-26PDF 86.7 KB
USERS MANUALUsers Manual1999-12-03PDF 346.2 KB
INTERNAL CHASSIS VIEW PHOTOGRAPHInternal Photos1999-12-03PDF 67.6 KB
INTERNAL COMPONENT VIEW PHOTOGRAPHInternal Photos1999-12-03PDF 198.3 KB
INTERNAL SOLDER SIDE PHOTOGRAPHInternal Photos1999-12-03PDF 201.1 KB
EXTERNAL FRONT VIEW PHOTOGRAPHExternal Photos1999-12-03PDF 75.4 KB
EXTERNAL REAR VIEW PHOTOGRAPHExternal Photos1999-12-03PDF 92 KB
EXTERNAL TOP VIEW PHOTOGRAPHExternal Photos1999-12-03PDF 73.6 KB
Label DrawingID Label/Location Info2001-09-26PDF 71.1 KB
Label PhotoID Label/Location Info2001-09-26PDF 266.3 KB
FCC ID LABEL SAMPLE AND SKETCH OF LOCATIONID Label/Location Info1999-12-03PDF 81.2 KB
BLOCK DIAGRAMBlock Diagram1999-12-03PDF 693.6 KB
MAIN SCHEMATICSchematics1999-12-03PDF 2.1 MB
SW SCHEMATICSchematics1999-12-03PDF 241.7 KB
CIRCUIT DESCRIPTIONOperational Description1999-12-03PDF 412.2 KB
Test Data supplied by applicantTest Report2001-09-26PDF 110.5 KB
AUDIO FREQUENCY RESPONSE GRAPH 5 KHZ CHTest Report1999-12-03PDF 4.8 KB
AUDIO FREQUENCY RESPONSE GRAPH TWO AND ONE HALF KHZ CHTest Report1999-12-03PDF 4.8 KB
AUDIO LOW PASS FILTER GRAPHTest Report1999-12-03PDF 458.4 KB
MODULATION LIMITING 5 KHZ CH SPACING 1000 HZTest Report1999-12-03PDF 4.7 KB
MODULATION LIMITING 5 KHZ CH SPACING 300 HZTest Report1999-12-03PDF 4.9 KB
MODULATION LIMITING 5 KHZ CH SPACING 3000 HZTest Report1999-12-03PDF 4.7 KB
MODULATION LIMITING TWO AND ONE HALF KHZ CH SPACING 1000 HZTest Report1999-12-03PDF 4.7 KB
MODULATION LIMITING TWO AND ONE HALF KHZ CH SPACING 300 HZTest Report1999-12-03PDF 4.8 KB
MODULATION LIMITING TWO AND ONE HALF KHZ CH SPACING 3000 HZTest Report1999-12-03PDF 4.7 KB
OCCUPIED BANDWIDTH PLOT 25 KHZ CHTest Report1999-12-03PDF 177.3 KB
OCCUPIED BANDWIDTH PLOT 25 KHZ PLOTTest Report1999-12-03PDF 174.2 KB
TEST REPORTTest Report1999-12-03PDF 22.8 KB
TRANSIENT FREQUENCY RESPONSE PLOTTest Report1999-12-03PDF 101.3 KB
Agent AuthorizationCover Letter(s)2001-09-26PDF 147.1 KB
Cover LettersCover Letter(s)2001-09-26PDF 10.5 KB
M Flom Reply to Correspondence 20493Cover Letter(s)2001-09-26PDF 8.8 KB
LETTER REGARDING FREQUENCY CHANGESCover Letter(s)1999-12-03PDF 120.9 KB
POWER OF ATTORNEY LETTERCover Letter(s)1999-12-03PDF 87.7 KB
WARNING STATEMENT FOR EQUIPMENTCover Letter(s)1999-12-03PDF 104.6 KB
Revised SAR ReportRF Exposure Info2001-09-26PDF 2.1 MB
SAR Report by Celltech Research IncRF Exposure Info2001-09-26PDF 1.3 MB
PARTS LISTParts List/Tune Up Info1999-12-03PDF 220.2 KB
TUNING PROCEDUREParts List/Tune Up Info1999-12-03PDF 286.8 KB

Application Information

Application IDQTEXJlXBCn08PnScZs2kbw==
Final Action Date2001-09-26
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0013655220
ModelVX-210U
Frequency Range450-490 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionTransmitter held to face
Responsible PartyTetsuya Masubuchi, Engineering Division/Quality Assurance Leader, t.masubuchi@yaesu.com , 81-3-6711-4121
AgentMorton Morton Morton, M. Flom Associates, Inc., general@mflom.com , 480 926 3100
Technical ContactMorton Flom, M. Flom Associates, Inc, general@mflom.com , 480 926 3100
Non-Technical ContactMorton Flom, M. Flom Associates, Inc., general@mflom.com , 480 926 3100
Test FirmMorton Flom, M. Flom Associates, Inc., info@mflom.com , 480-926-3100
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is at the antenna terminal on the device. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations with a specific antenna, and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50%. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user's body. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values at 50% duty factor are - Head: 3.02 W/kg; Body-worn: 4.98 W/kg.

Applications

Application IDDatePurpose
QTEXJlXBCn08PnScZs2kbw==2001-09-26Class II permissive change or modification of presently authorized equipment
I3uL0UBaK2NIgvgGiaIKaw==1999-12-03Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
450-485 MHz50.00025%16K0F3E22, 74, 90, 95
450-490 MHz50.00025%16K0F3E22, 74, 90, 95
450-485 MHz50.00025%11K0F3E
450-490 MHz50.00025%11K0F3E22, 74, 90.210, 95
450-490 MHz10.00025%16K0F3E22, 74, 90, 95
450-490 MHz10.00025%11K0F3E22, 74, 90.210, 95

Grants

TCB Grant - Application QTEXJlXBCn08PnScZs2kbw==

This application does not exist.

EAS Grant - Application QTEXJlXBCn08PnScZs2kbw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Yaesu Musen Co., Ltd.
Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku
Tokyo, 140-0002
Japan
  Date of Grant: 09/26/2001

Application Dated: 07/02/2001
 
Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  K66VX-210U
Name of Grantee:  Yaesu Musen Co., Ltd.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Transmitter held to face
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22, 74, 90, 95 450.0  -  490.0 5.0 0.00025  % 16K0F3E
22, 74, 95, 90.210 450.0  -  490.0 5.0 0.00025  % 11K0F3E
22, 74, 90, 95 450.0  -  490.0 1.0 0.00025  % 16K0F3E
22, 74, 95, 90.210 450.0  -  490.0 1.0 0.00025  % 11K0F3E

Power output listed is at the antenna terminal on the device. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations with a specific antenna, and only satisfies SAR limit for Occupational/Controlled RF Exposure Environment. Device must operate at a duty factor not exceeding 50%. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user's body. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values at 50% duty factor are - Head: 3.02 W/kg; Body-worn: 4.98 W/kg.



TCB Grant - Application I3uL0UBaK2NIgvgGiaIKaw==

This application does not exist.

EAS Grant - Application I3uL0UBaK2NIgvgGiaIKaw==

Mail To:
Morton Flom, P. Eng., President
M. Flom Associates, Inc.
3356 N. San Marcos Pl., Suite 107
Chandler, AZ 85225-7176
COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Yaesu Musen Co., Ltd.
Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku
Tokyo, 140-0002
Japan
  Date of Grant: 12/03/1999

Application Dated: 08/26/1999
 
Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  K66VX-210U
Name of Grantee:  Yaesu Musen Co., Ltd.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: UHF TRANSCEIVER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22, 74, 90, 95 450.0  -  485.0 5.0 0.00025  % 16K0F3E
450.0  -  485.0 5.0 0.00025  % 11K0F3E

The transmitter can also be operated at 1 watt RF output power.



Mail To:
S. S. SANDERS, ENGINEER
TIMCO ENGINEERING, INC.
P.O. BOX 370
NEWBERRY, FL 32669