FCC ID K66VX-3200V-2
VHF FM Nonbroadcast Transceiver
by Yaesu Musen Co., Ltd.
Grantee Code: K66 Product Code: VX3200V2
Latest application date: 2003-01-17
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 134-165 MHz | Original Equipment | 2003-01-17 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| operating manual | Users Manual | 2003-01-17 | PDF 423.5 KB |
| internal photos | Internal Photos | 2003-01-17 | PDF 1.4 MB |
| external photos | External Photos | 2003-01-17 | PDF 921.6 KB |
| label | ID Label/Location Info | 2003-01-17 | PDF 1.9 MB |
| circuit description | Operational Description | 2003-01-17 | PDF 87 KB |
| amended data for test report | Test Report | 2003-01-17 | PDF 108.9 KB |
| test report 1 | Test Report | 2003-01-17 | PDF 435.7 KB |
| test report 2 | RF Exposure Info | 2003-01-17 | PDF 195.9 KB |
| compliance statement 15 19 | Attestation Statements | 2003-01-17 | PDF 68.4 KB |
| compliance statement 15 21 | Attestation Statements | 2003-01-17 | PDF 95.4 KB |
| compliance statement 90 203 | Attestation Statements | 2003-01-17 | PDF 92 KB |
| confidentiatly request | Cover Letter(s) | 2003-01-17 | PDF 119.8 KB |
| alignment procedure | Parts List/Tune Up Info | 2003-01-17 | PDF 127.9 KB |
| component application | Parts List/Tune Up Info | 2003-01-17 | PDF 10.5 KB |
| specifications by Canada | Parts List/Tune Up Info | 2003-01-17 | PDF 19.8 KB |
| specifications by FCC | Parts List/Tune Up Info | 2003-01-17 | PDF 20 KB |
| RF block diagram Metadata only | Block Diagram | PDF 421.1 KB | |
| panel block diagram Metadata only | Block Diagram | PDF 410.8 KB | |
| connection diagram Metadata only | Schematics | PDF 271.5 KB | |
| panel unit Metadata only | Schematics | PDF 1.4 MB | |
| rf unit 1 Metadata only | Schematics | PDF 1.5 MB | |
| rf unit 2 Metadata only | Schematics | PDF 531.8 KB |
Application Information
| Application ID | d32GR4PsAhV/8pAEOLg+CQ== |
|---|---|
| Final Action Date | 2003-01-17 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0013655220 |
| Model | VX-3200V-2 |
| Frequency Range | 134-165 MHz |
| Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter |
| Device Description | VHF FM Nonbroadcast Transceiver |
| Responsible Party | Tetsuya Masubuchi, Engineering Division/Quality Assurance Leader, t.masubuchi@yaesu.com |
| Test Firm | Morton Flom, M. Flom Associates, Inc., info@mflom.com |
| TCB Email | tei@timcoengr.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 61cm from all persons and must not exceed an antenna gain of 0 dBd. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| d32GR4PsAhV/8pAEOLg+CQ== | 2003-01-17 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application d32GR4PsAhV/8pAEOLg+CQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 01/17/2003 Application Dated: 01/17/2003 |
| Yaesu Musen Co., Ltd. |
| Tennozu Parkside Building |
| 2-5-8 Higashi-Shinagawa, Shinagawa-ku |
| Tokyo, 140-0002 Japan |
| Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | K66VX-3200V-2 |
| Name of Grantee: | Yaesu Musen Co., Ltd. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | VHF FM Nonbroadcast Transceiver |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BD | 90 | 134.0 - 165.0 | 10.0 | 2.5 PM | 16K0F3E |
| BD | 90 | 134.0 - 165.0 | 50.0 | 2.5 PM | 16K0F3E |
| BD | 90.210 | 134.0 - 165.0 | 10.0 | 2.5 PM | 11K0F3E |
| BD | 90.210 | 134.0 - 165.0 | 50.0 | 2.5 PM | 11K0F3E |
| Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 61cm from all persons and must not exceed an antenna gain of 0 dBd. |
| BD: | The output power is continuously variable from the value listed in this entry to 10%-15% of the value listed. |
EAS Grant - Application d32GR4PsAhV/8pAEOLg+CQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Yaesu Musen Co., Ltd. Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku Tokyo, 140-0002 Japan |
Date of Grant: 01/17/2003 Application Dated: 01/17/2003 |
| Attention: Tetsuya Masubuchi , Engineering Division/Quality Assurance Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | K66VX-3200V-2 |
| Name of Grantee: | Yaesu Musen Co., Ltd. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | VHF FM Nonbroadcast Transceiver |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BD | 90 | 134.0 - 165.0 | 10.0 | 2.5 PM | 16K0F3E |
| BD | 90 | 134.0 - 165.0 | 50.0 | 2.5 PM | 16K0F3E |
| BD | 90.210 | 134.0 - 165.0 | 10.0 | 2.5 PM | 11K0F3E |
| BD | 90.210 | 134.0 - 165.0 | 50.0 | 2.5 PM | 11K0F3E |
| Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Controlled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 61cm from all persons and must not exceed an antenna gain of 0 dBd. |
| BD: | The output power is continuously variable from the value listed in this entry to 10%-15% of the value listed. |
| Mail To: |