FCC ID LPN-R80

Pulsar Model R80

by AMETEK Magnetrol USA, LLC

Grantee Code: LPN   Product Code: R80
Latest application date: 2022-01-12

FCC ID Device Details

FCC IDLPN-R80
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeLPN
Product CodeR80
Applicant BusinessAMETEK Magnetrol USA, LLC 🇺🇸
Related Domains magnetrol.com rheintech.com
Equipment ClassPulsar Model R80
Test FirmRhein Tech Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
79000 MHzOriginal Equipment2022-01-12

Exhibits

DocumentTypeAvailableFile
Manual_RevD_58-604 Model R80Users Manual2022-07-11PDF 3.8 MB
R80 Internal PhotosInternal Photos2022-07-11PDF 2.4 MB
R80 External PhotosExternal Photos2022-07-11PDF 1.3 MB
R80 ID Label and LocationID Label/Location Info2022-01-12PDF 139 KB
Magnetrol R80 FCC15.209 ISED TestPh R0.0Test Setup Photos2022-07-11PDF 938.5 KB
Magnetrol R80 FCC15.256 ISED TestPhotos R0.0Test Setup Photos2022-07-11PDF 307.5 KB
2021097 Magnetrol R80 FCC15.256 ISED Test Report Only R3.0Test Report2022-01-12PDF 1.2 MB
2021097 Magnetrol R80 FCC15.256 ISED Test Report RFExposure R3.0RF Exposure Info2022-01-12PDF 167.2 KB
FCC Agent Authority Letter 090221Cover Letter(s)2022-01-12PDF 161.3 KB
FCC ISED Confidentiality Request Letter 090221Cover Letter(s)2022-01-12PDF 198.9 KB
Pulsar Model R80 Block Diagram Revised B Metadata onlyBlock DiagramPDF 51.9 KB
R80 Schematics Complete Metadata onlySchematicsPDF 484.4 KB
Comments and Response Metadata onlyOperational DescriptionPDF 77.2 KB
KDB Antenna discussion Metadata onlyOperational DescriptionPDF 2.2 MB
Pulsar Model R80 Technical Operational description_Revised_D Metadata onlyOperational DescriptionPDF 339 KB

Application Information

Application IDI+N+Yt3BglyFfkTBkq1ZJA==
Final Action Date2022-01-12
Application PurposeOriginal Equipment
Applicant FRN0007112394
ModelR80
Frequency Range79000 MHz
Equipment ClassLPR - Level Probing Radar
Device DescriptionPulsar Model R80
Responsible PartyWarren Jobe, Sr. Compliance Engineer, wjobe@magnetrol.com , 6307236604
AgentKathy Kathy Kathy, Rhein Tech Laboratories, Inc., atcbinfo@rheintech.com , 7032302741
Technical ContactDesmond Fraswe, Rhein Tech Laboratories, Inc, desmond@rheintech.com , 7036890368
Non-Technical ContactKathy Grzovic, Rhein Tech Laboratories, Inc, atcbinfo@rheintech.com , 7032302741
Test FirmRichard McMurray, Rhein Tech Laboratories, Inc., rmcmurray@rheintech.com , 703-689-0368
TCB Emailhotline@acbcert.com
TCB ScopeA2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
Short-Term ConfidentialityYes
Short-Term Confidentiality Date07/11/2022
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsThis device is approved for downward configurations when installed in a fully enclosed stationary metal, concrete or reinforced fiberglass vessels only. For operation outside of closed metal, concrete, and reinforced fiberglass vessels under 15.256, only the 2 inch and 3 inch Horn antennas may be used and must be installed and maintained to ensure a vertically downward orientation of the transmit antenna's main beam. Additionally under 15.256 the device may only operate at fixed locations and may not operate while being moved, or while inside a moving container. Hand-held applications are prohibited.

Applications

Application IDDatePurpose
I+N+Yt3BglyFfkTBkq1ZJA==2022-01-12Original Equipment

Equipment Authorization

FrequencyRules
79000 MHz15.209, 15.256

Grants

TCB Grant - Application I+N+Yt3BglyFfkTBkq1ZJA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 01/12/2022

Application Dated: 01/12/2022
AMETEK Magnetrol USA, LLC
705 Enterprise Streeet
Aurora, IL 60504
 
Attention: Warren Jobe , Sr. Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LPN-R80
Name of Grantee:  AMETEK Magnetrol USA, LLC
Equipment Class: Level Probing Radar
Notes: Pulsar Model R80
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15.209, 15.256 79000.0  -  79000.0  

This device is approved for downward configurations when installed in a fully enclosed stationary metal, concrete or reinforced fiberglass vessels only.

For operation outside of closed metal, concrete, and reinforced fiberglass vessels under 15.256, only the 2 inch and 3 inch Horn antennas may be used and must be installed and maintained to ensure a vertically downward orientation of the transmit antenna's main beam. Additionally under 15.256 the device may only operate at fixed locations and may not operate while being moved, or while inside a moving container. Hand-held applications are prohibited.


EAS Grant - Application I+N+Yt3BglyFfkTBkq1ZJA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

AMETEK Magnetrol USA, LLC
705 Enterprise Streeet
Aurora, IL 60504
United States
  Date of Grant: 01/12/2022

Application Dated: 01/12/2022
 
Attention: Warren Jobe , Sr. Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  LPN-R80
Name of Grantee:  AMETEK Magnetrol USA, LLC
Equipment Class: Level Probing Radar
Notes: Pulsar Model R80
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15.209, 15.256 79000.0  -  79000.0  

This device is approved for downward configurations when installed in a fully enclosed stationary metal, concrete or reinforced fiberglass vessels only.

For operation outside of closed metal, concrete, and reinforced fiberglass vessels under 15.256, only the 2 inch and 3 inch Horn antennas may be used and must be installed and maintained to ensure a vertically downward orientation of the transmit antenna's main beam. Additionally under 15.256 the device may only operate at fixed locations and may not operate while being moved, or while inside a moving container. Hand-held applications are prohibited.



Mail To: