FCC ID N6FCI00059

CI00059

by ADI Limited, Systems Group

Grantee Code: N6F   Product Code: CI00059
Latest application date: 1999-10-21

FCC ID Device Details

FCC IDN6FCI00059
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeN6F
Product CodeCI00059
Applicant BusinessADI Limited, Systems Group 🇦🇺
Related Domains sg.adisys.com.au mflom.com
Equipment ClassCI00059
Test FirmM. Flom Associates, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
136-174 MHzOriginal Equipment1999-10-21

Exhibits

DocumentTypeAvailableFile
8Users Manual1999-10-21PDF 2.6 MB
9Internal Photos1999-10-21PDF 672.4 KB
3External Photos1999-10-21PDF 2.5 MB
1ID Label/Location Info1999-10-21PDF 31.7 KB
12Operational Description1999-10-21PDF 92.9 KB
6Test Report1999-10-21PDF 863.3 KB
Additional Transient Freq PlotsTest Report1999-10-21PDF 225.1 KB
More Transient Freq PlotsTest Report1999-10-21PDF 346.8 KB
13 Metadata onlyCover Letter(s)1999-10-21PDF 285.6 KB
Additional infoCover Letter(s)1999-10-21PDF 289.4 KB
5 Metadata onlySchematicsPDF 242.3 KB
5a Metadata onlySchematicsPDF 76.1 KB

Application Information

Application IDT5Vfadd5a/wDqb8z3DDvCg==
Final Action Date1999-10-21
Application PurposeOriginal Equipment
Applicant FRN9999999999
ModelCI00059
Frequency Range136-174 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Responsible PartySteve Tucker, Engineer Manager, tucker@sg.adisys.com.au , 613-820-2730
AgentMorton Morton Morton, M. Flom Associates Inc, general@mflom.com , 480 926-3100
Technical ContactMorton Flom, M. Flom Associates Inc, general@mflom.com , 480 926-3100
Non-Technical ContactMorton Flom, M. Flom Associates Inc, general@mflom.com , 480 926-3100
Test FirmMorton Flom, M. Flom Associates, Inc., info@mflom.com , 480-926-3100
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsSingle channel mode.

Applications

Application IDDatePurpose
T5Vfadd5a/wDqb8z3DDvCg==1999-10-21Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
136-174 MHz602.5ppm16K0F3E9BC
136-174 MHz602.5ppm16K0F1E9BC
136-174 MHz602.5ppm11K0F3E90.21BC
136-174 MHz602.5ppm11K0F1E90.21BC

Grants

TCB Grant - Application T5Vfadd5a/wDqb8z3DDvCg==

This application does not exist.

EAS Grant - Application T5Vfadd5a/wDqb8z3DDvCg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ADI Limited, Systems Group
4 Talavera Road
North Ryde, NSW 2113
Australia
  Date of Grant: 10/21/1999

Application Dated: 06/22/1999
 
Attention: Steve Tucker , Engineer Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  N6FCI00059
Name of Grantee:  ADI Limited, Systems Group
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes:
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 90 136.0  -  174.0 60.0 2.5  PM 16K0F3E
BC 90 136.0  -  174.0 60.0 2.5  PM 16K0F1E
BC 90.210 136.0  -  174.0 60.0 2.5  PM 11K0F3E
BC 90.210 136.0  -  174.0 60.0 2.5  PM 11K0F1E

Single channel mode.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

Mail To:
Morton Flom, President
M. Flom Associates Inc
3356 N San Marcos Place, Suite 107
Chandler, AZ 8522-1571