FCC ID PKRISGSKR3MD8800
Wireless Router
by Inseego Corp.
Grantee Code: PKR Product Code: ISGSKR3MD8800
Latest application date: 2019-03-16
FCC ID Device Details
| FCC ID | PKRISGSKR3MD8800 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | PKR |
| Product Code | ISGSKR3MD8800 |
| Applicant Business | Inseego Corp. 🇺🇸 |
| Related Domains | |
| Equipment Class | Wireless Router |
| Test Firm | TUV SUD America Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 779.5-784.5 MHz | Original Equipment | 2019-03-16 |
| 5180-5240 MHz | Original Equipment | 2019-03-16 |
| 2402-2480 MHz | Original Equipment | 2019-03-16 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2019-09-11 | PDF 2.1 MB |
| Internal Photos | Internal Photos | 2019-09-11 | PDF 3.6 MB |
| External Photos | External Photos | 2019-09-11 | PDF 1.2 MB |
| Label | ID Label/Location Info | 2019-03-16 | PDF 409.4 KB |
| Label Location | ID Label/Location Info | 2019-03-16 | PDF 1.5 MB |
| Test Setup Photos | Test Setup Photos | 2019-09-11 | PDF 693.8 KB |
| Test Setup Photos | Test Setup Photos | 2019-09-11 | PDF 524.5 KB |
| Test Report | Test Report | 2019-03-16 | PDF 1.6 MB |
| Test Report I | Test Report | 2019-03-16 | PDF 1.5 MB |
| Test Report I Part 1 | Test Report | 2019-03-16 | PDF 2.1 MB |
| Test Report I Part 2 | Test Report | 2019-03-16 | PDF 5.2 MB |
| Test Report II | Test Report | 2019-03-16 | PDF 966.3 KB |
| Test Report II Part 1 | Test Report | 2019-03-16 | PDF 5.4 MB |
| Test Report II Part 2 | Test Report | 2019-03-16 | PDF 5.7 MB |
| Test Report III | Test Report | 2019-03-16 | PDF 3 MB |
| Test Report III | Test Report | 2019-03-16 | PDF 682.7 KB |
| Test Report IV | Test Report | 2019-03-16 | PDF 5.3 MB |
| Attestation Letter | Cover Letter(s) | 2019-03-16 | PDF 56.2 KB |
| Attestation Letter II | Cover Letter(s) | 2019-03-16 | PDF 47.6 KB |
| Agents Letter | Cover Letter(s) | 2019-03-16 | PDF 141 KB |
| Confidentiality Letter | Cover Letter(s) | 2019-03-16 | PDF 132 KB |
| RF Exposure Report | RF Exposure Info | 2019-03-16 | PDF 262.9 KB |
| Block Diagram Metadata only | Block Diagram | PDF 207.4 KB | |
| Schematics Metadata only | Schematics | PDF 782.6 KB | |
| Operating Description Metadata only | Operational Description | PDF 142.8 KB | |
| Operating Description II Metadata only | Operational Description | PDF 48.9 KB | |
| Tune Up Metadata only | Parts List/Tune Up Info | PDF 196.7 KB |
Application Information
| Application ID | NAOH3k+Bj0Dngicq7fpioA== |
|---|---|
| Final Action Date | 2019-03-16 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0003757176 |
| Model | ISGSKR3MD8800 |
| Frequency Range | 779.5-784.5 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Wireless Router |
| Responsible Party | Roman Olmos, Staff Regulatory Engineer, Roman.Olmos@inseego.com |
| Test Firm | Mac Elliott, TUV SUD America Inc., William.Elliott@tuvsud.com |
| TCB Email | Andy.Zhang@tuvsud.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 09/11/2019 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power is ERP for Part 22 / Part 90 and EIRP for Part 24 / Part 27. This device and its antenna(s) must be installed to provide a separation distance of at least 27 cm from all persons. End users must be informed of the final installation requirements for meeting FCC RF Exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| NAOH3k+Bj0Dngicq7fpioA== | 2019-03-16 | Original Equipment |
| 4ZLMfJfROKEf/JrmFPr4kg== | 2019-03-16 | Original Equipment |
| /3TnuGn3RzWNOSiAGqTtmg== | 2019-03-16 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 779.5-784.5 MHz | 0.216 | 0.1ppm | 4M46G7D | 27 | |
| 779.5-784.5 MHz | 0.183 | 0.1ppm | 4M47W7D | 27 | |
| 782 MHz | 0.215 | 0.1ppm | 8M92G7D | 27 | |
| 782 MHz | 0.107 | 0.1ppm | 8M91W7D | 27 | |
| 790.5-795.5 MHz | 0.13 | 1.25ppm | 4M49G7D | 9 | |
| 790.5-795.5 MHz | 0.11 | 1.25ppm | 4M48W7D | 9 | |
| 793 MHz | 0.13 | 1.25ppm | 8M95G7D | 9 | |
| 793 MHz | 0.11 | 1.25ppm | 8M95W7D | 9 | |
| 824.7-848.3 MHz | 0.136 | 2.5ppm | 1M09G7D | 22H | |
| 824.7-848.3 MHz | 0.109 | 2.5ppm | 1M09W7D | 22H | |
| 825.5-847.5 MHz | 0.134 | 2.5ppm | 2M69G7D | 22H | |
| 825.5-847.5 MHz | 0.11 | 2.5ppm | 2M69W7D | 22H | |
| 826.5-846.5 MHz | 0.136 | 2.5ppm | 4M49G7D | 22H | |
| 826.5-846.5 MHz | 0.116 | 2.5ppm | 4M47W7D | 22H | |
| 829-844 MHz | 0.136 | 2.5ppm | 8M94G7D | 22H | |
| 829-844 MHz | 0.113 | 2.5ppm | 8M93W7D | 22H | |
| 1710.7-1754.3 MHz | 0.247 | 0.1ppm | 1M09G7D | 27 | |
| 1710.7-1754.3 MHz | 0.184 | 0.1ppm | 1M10W7D | 27 | |
| 1710.7-1779.3 MHz | 0.248 | 0.1ppm | 1M10G7D | 27 | |
| 1710.7-1779.3 MHz | 0.188 | 0.1ppm | 1M09W7D | 27 | |
| 1711.5-1753.5 MHz | 0.248 | 0.1ppm | 2M70G7D | 27 | |
| 1711.5-1753.5 MHz | 0.185 | 0.1ppm | 2M70W7D | 27 | |
| 1711.5-1778.5 MHz | 0.246 | 0.1ppm | 2M70G7D | 27 | |
| 1711.5-1778.5 MHz | 0.187 | 0.1ppm | 2M70W7D | 27 | |
| 1712.5-1752.5 MHz | 0.248 | 0.1ppm | 4M50G7D | 27 | |
| 1712.5-1752.5 MHz | 0.192 | 0.1ppm | 4M49W7D | 27 | |
| 1712.5-1777.5 MHz | 0.248 | 0.1ppm | 4M50G7D | 27 | |
| 1712.5-1777.5 MHz | 0.2 | 0.1ppm | 4M48W7D | 27 | |
| 1715-1750 MHz | 0.247 | 0.1ppm | 8M99G7D | 27 | |
| 1715-1750 MHz | 0.188 | 0.1ppm | 8M98W7D | 27 | |
| 1715-1775 MHz | 0.251 | 0.1ppm | 8M98G7D | 27 | |
| 1715-1775 MHz | 0.188 | 0.1ppm | 8M48W7D | 27 | |
| 1717.5-1747.5 MHz | 0.25 | 0.1ppm | 13M5G7D | 27 | |
| 1717.5-1747.5 MHz | 0.208 | 0.1ppm | 13M5W7D | 27 | |
| 1717.5-1772.5 MHz | 0.247 | 0.1ppm | 13M5G7D | 27 | |
| 1717.5-1772.5 MHz | 0.192 | 0.1ppm | 13M5W7D | 27 | |
| 1720-1745 MHz | 0.25 | 0.1ppm | 17M9G7D | 27 | |
| 1720-1745 MHz | 0.208 | 0.1ppm | 17M9W7D | 27 | |
| 1720-1770 MHz | 0.25 | 0.1ppm | 18M0G7D | 27 | |
| 1720-1770 MHz | 0.19 | 0.1ppm | 18M0W7D | 27 | |
| 1850.7-1909.3 MHz | 0.227 | 2.5ppm | 1M09W7D | 24E | |
| 1851.5-1908.5 MHz | 0.23 | 2.5ppm | 2M69W7D | 24E | |
| 1852.5-1907.5 MHz | 0.233 | 2.5ppm | 4M49W7D | 24E | |
| 1855-1905 MHz | 0.24 | 2.5ppm | 8M95W7D | 24E | |
| 1857.5-1902.5 MHz | 0.234 | 2.5ppm | 13M4W7D | 24E | |
| 1857.5-1902.5 MHz | 0.277 | 2.5ppm | 13M4G7D | 24E | |
| 1860-1900 MHz | 0.234 | 2.5ppm | 17M9W7D | 24E | |
| 1860-1900 MHz | 0.279 | 2.5ppm | 17M8G7D | 24E | |
| 2402-2480 MHz | 0.005 | 15C | CC | ||
| 2412-2462 MHz | 0.609 | 15C | CC, MO | ||
| 2502.5-2567.5 MHz | 0.397 | 0.1ppm | 4M48G7D | 27 | |
| 2502.5-2567.5 MHz | 0.343 | 0.1ppm | 4M49W7D | 27 | |
| 2505-2565 MHz | 0.345 | 0.1ppm | 8M97G7D | 27 | |
| 2505-2565 MHz | 0.292 | 0.1ppm | 8M96W7D | 27 | |
| 2507.5-2562.5 MHz | 0.348 | 0.1ppm | 13M4G7D | 27 | |
| 2507.5-2562.5 MHz | 0.292 | 0.1ppm | 13M5W7D | 27 | |
| 2510-2560 MHz | 0.344 | 0.1ppm | 17M9G7D | 27 | |
| 2510-2560 MHz | 0.288 | 0.1ppm | 17M9W7D | 27 | |
| 5180-5240 MHz | 0.323 | 15E | CC, MO | ||
| 5745-5825 MHz | 0.524 | 15E | CC, MO |
Grants
TCB Grant - Application NAOH3k+Bj0Dngicq7fpioA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD America Inc. 401 Edgewater Place Suite #500 Wakefield, MA 01880 |
Date of Grant: 03/16/2019 Application Dated: 03/15/2019 |
| Inseego Corp. |
| 9710 Scranton Road |
| Suite 200 |
| San Diego, CA 92121 |
| Attention: Roman Olmos , Staff Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PKRISGSKR3MD8800 |
| Name of Grantee: | Inseego Corp. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Wireless Router |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 826.4 - 846.6 | 0.136 | 2.5 PM | 4M22F9W | |
| 24E | 1852.4 - 1907.6 | 0.249 | 2.5 PM | 4M14F9W | |
| 24E | 1850.7 - 1909.3 | 0.278 | 2.5 PM | 1M09G7D | |
| 24E | 1851.5 - 1908.5 | 0.276 | 2.5 PM | 2M69G7D | |
| 24E | 1852.5 - 1907.5 | 0.282 | 2.5 PM | 4M49G7D | |
| 24E | 1855.0 - 1905.0 | 0.282 | 2.5 PM | 8M95G7D | |
| 24E | 1857.5 - 1902.5 | 0.277 | 2.5 PM | 13M4G7D | |
| 24E | 1860.0 - 1900.0 | 0.279 | 2.5 PM | 17M8G7D | |
| 24E | 1850.7 - 1909.3 | 0.227 | 2.5 PM | 1M09W7D | |
| 24E | 1851.5 - 1908.5 | 0.23 | 2.5 PM | 2M69W7D | |
| 24E | 1852.5 - 1907.5 | 0.233 | 2.5 PM | 4M49W7D | |
| 24E | 1855.0 - 1905.0 | 0.24 | 2.5 PM | 8M95W7D | |
| 24E | 1857.5 - 1902.5 | 0.234 | 2.5 PM | 13M4W7D | |
| 24E | 1860.0 - 1900.0 | 0.234 | 2.5 PM | 17M9W7D | |
| 22H | 824.7 - 848.3 | 0.136 | 2.5 PM | 1M09G7D | |
| 22H | 825.5 - 847.5 | 0.134 | 2.5 PM | 2M69G7D | |
| 22H | 826.5 - 846.5 | 0.136 | 2.5 PM | 4M49G7D | |
| 22H | 829.0 - 844.0 | 0.136 | 2.5 PM | 8M94G7D | |
| 22H | 824.7 - 848.3 | 0.109 | 2.5 PM | 1M09W7D | |
| 22H | 825.5 - 847.5 | 0.11 | 2.5 PM | 2M69W7D | |
| 22H | 826.5 - 846.5 | 0.116 | 2.5 PM | 4M47W7D | |
| 22H | 829.0 - 844.0 | 0.113 | 2.5 PM | 8M93W7D | |
| 27 | 1710.7 - 1754.3 | 0.247 | 0.1 PM | 1M09G7D | |
| 27 | 1711.5 - 1753.5 | 0.248 | 0.1 PM | 2M70G7D | |
| 27 | 1712.5 - 1752.5 | 0.248 | 0.1 PM | 4M50G7D | |
| 27 | 1715.0 - 1750.0 | 0.247 | 0.1 PM | 8M99G7D | |
| 27 | 1717.5 - 1747.5 | 0.25 | 0.1 PM | 13M5G7D | |
| 27 | 1720.0 - 1745.0 | 0.25 | 0.1 PM | 17M9G7D | |
| 27 | 1710.7 - 1754.3 | 0.184 | 0.1 PM | 1M10W7D | |
| 27 | 1711.5 - 1753.5 | 0.185 | 0.1 PM | 2M70W7D | |
| 27 | 1712.5 - 1752.5 | 0.192 | 0.1 PM | 4M49W7D | |
| 27 | 1715.0 - 1750.0 | 0.188 | 0.1 PM | 8M98W7D | |
| 27 | 1717.5 - 1747.5 | 0.208 | 0.1 PM | 13M5W7D | |
| 27 | 1720.0 - 1745.0 | 0.208 | 0.1 PM | 17M9W7D | |
| 27 | 2502.5 - 2567.5 | 0.397 | 0.1 PM | 4M48G7D | |
| 27 | 2505.0 - 2565.0 | 0.345 | 0.1 PM | 8M97G7D | |
| 27 | 2507.5 - 2562.5 | 0.348 | 0.1 PM | 13M4G7D | |
| 27 | 2510.0 - 2560.0 | 0.344 | 0.1 PM | 17M9G7D | |
| 27 | 2502.5 - 2567.5 | 0.343 | 0.1 PM | 4M49W7D | |
| 27 | 2505.0 - 2565.0 | 0.292 | 0.1 PM | 8M96W7D | |
| 27 | 2507.5 - 2562.5 | 0.292 | 0.1 PM | 13M5W7D | |
| 27 | 2510.0 - 2560.0 | 0.288 | 0.1 PM | 17M9W7D | |
| 27 | 779.5 - 784.5 | 0.216 | 0.1 PM | 4M46G7D | |
| 27 | 782.0 - 782.0 | 0.215 | 0.1 PM | 8M92G7D | |
| 27 | 779.5 - 784.5 | 0.183 | 0.1 PM | 4M47W7D | |
| 27 | 782.0 - 782.0 | 0.107 | 0.1 PM | 8M91W7D | |
| 27 | 1710.7 - 1779.3 | 0.248 | 0.1 PM | 1M10G7D | |
| 27 | 1711.5 - 1778.5 | 0.246 | 0.1 PM | 2M70G7D | |
| 27 | 1712.5 - 1777.5 | 0.248 | 0.1 PM | 4M50G7D | |
| 27 | 1715.0 - 1775.0 | 0.251 | 0.1 PM | 8M98G7D | |
| 27 | 1717.5 - 1772.5 | 0.247 | 0.1 PM | 13M5G7D | |
| 27 | 1720.0 - 1770.0 | 0.25 | 0.1 PM | 18M0G7D | |
| 27 | 1710.7 - 1779.3 | 0.188 | 0.1 PM | 1M09W7D | |
| 27 | 1711.5 - 1778.5 | 0.187 | 0.1 PM | 2M70W7D | |
| 27 | 1712.5 - 1777.5 | 0.2 | 0.1 PM | 4M48W7D | |
| 27 | 1715.0 - 1775.0 | 0.188 | 0.1 PM | 8M48W7D | |
| 27 | 1717.5 - 1772.5 | 0.192 | 0.1 PM | 13M5W7D | |
| 27 | 1720.0 - 1770.0 | 0.19 | 0.1 PM | 18M0W7D | |
| 90 | 790.5 - 795.5 | 0.13 | 1.25 PM | 4M49G7D | |
| 90 | 793.0 - 793.0 | 0.13 | 1.25 PM | 8M95G7D | |
| 90 | 790.5 - 795.5 | 0.11 | 1.25 PM | 4M48W7D | |
| 90 | 793.0 - 793.0 | 0.11 | 1.25 PM | 8M95W7D |
| Output power is ERP for Part 22 / Part 90 and EIRP for Part 24 / Part 27. This device and its antenna(s) must be installed to provide a separation distance of at least 27 cm from all persons. End users must be informed of the final installation requirements for meeting FCC RF Exposure compliance. |
EAS Grant - Application NAOH3k+Bj0Dngicq7fpioA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Inseego Corp. 9710 Scranton Road Suite 200 San Diego, CA 92121 United States |
Date of Grant: 03/16/2019 Application Dated: 03/15/2019 |
| Attention: Roman Olmos , Staff Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PKRISGSKR3MD8800 |
| Name of Grantee: | Inseego Corp. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Wireless Router |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 826.4 - 846.6 | 0.136 | 2.5 PM | 4M22F9W | |
| 24E | 1852.4 - 1907.6 | 0.249 | 2.5 PM | 4M14F9W | |
| 24E | 1850.7 - 1909.3 | 0.278 | 2.5 PM | 1M09G7D | |
| 24E | 1851.5 - 1908.5 | 0.276 | 2.5 PM | 2M69G7D | |
| 24E | 1852.5 - 1907.5 | 0.282 | 2.5 PM | 4M49G7D | |
| 24E | 1855.0 - 1905.0 | 0.282 | 2.5 PM | 8M95G7D | |
| 24E | 1857.5 - 1902.5 | 0.277 | 2.5 PM | 13M4G7D | |
| 24E | 1860.0 - 1900.0 | 0.279 | 2.5 PM | 17M8G7D | |
| 24E | 1850.7 - 1909.3 | 0.227 | 2.5 PM | 1M09W7D | |
| 24E | 1851.5 - 1908.5 | 0.23 | 2.5 PM | 2M69W7D | |
| 24E | 1852.5 - 1907.5 | 0.233 | 2.5 PM | 4M49W7D | |
| 24E | 1855.0 - 1905.0 | 0.24 | 2.5 PM | 8M95W7D | |
| 24E | 1857.5 - 1902.5 | 0.234 | 2.5 PM | 13M4W7D | |
| 24E | 1860.0 - 1900.0 | 0.234 | 2.5 PM | 17M9W7D | |
| 22H | 824.7 - 848.3 | 0.136 | 2.5 PM | 1M09G7D | |
| 22H | 825.5 - 847.5 | 0.134 | 2.5 PM | 2M69G7D | |
| 22H | 826.5 - 846.5 | 0.136 | 2.5 PM | 4M49G7D | |
| 22H | 829.0 - 844.0 | 0.136 | 2.5 PM | 8M94G7D | |
| 22H | 824.7 - 848.3 | 0.109 | 2.5 PM | 1M09W7D | |
| 22H | 825.5 - 847.5 | 0.11 | 2.5 PM | 2M69W7D | |
| 22H | 826.5 - 846.5 | 0.116 | 2.5 PM | 4M47W7D | |
| 22H | 829.0 - 844.0 | 0.113 | 2.5 PM | 8M93W7D | |
| 27 | 1710.7 - 1754.3 | 0.247 | 0.1 PM | 1M09G7D | |
| 27 | 1711.5 - 1753.5 | 0.248 | 0.1 PM | 2M70G7D | |
| 27 | 1712.5 - 1752.5 | 0.248 | 0.1 PM | 4M50G7D | |
| 27 | 1715.0 - 1750.0 | 0.247 | 0.1 PM | 8M99G7D | |
| 27 | 1717.5 - 1747.5 | 0.25 | 0.1 PM | 13M5G7D | |
| 27 | 1720.0 - 1745.0 | 0.25 | 0.1 PM | 17M9G7D | |
| 27 | 1710.7 - 1754.3 | 0.184 | 0.1 PM | 1M10W7D | |
| 27 | 1711.5 - 1753.5 | 0.185 | 0.1 PM | 2M70W7D | |
| 27 | 1712.5 - 1752.5 | 0.192 | 0.1 PM | 4M49W7D | |
| 27 | 1715.0 - 1750.0 | 0.188 | 0.1 PM | 8M98W7D | |
| 27 | 1717.5 - 1747.5 | 0.208 | 0.1 PM | 13M5W7D | |
| 27 | 1720.0 - 1745.0 | 0.208 | 0.1 PM | 17M9W7D | |
| 27 | 2502.5 - 2567.5 | 0.397 | 0.1 PM | 4M48G7D | |
| 27 | 2505.0 - 2565.0 | 0.345 | 0.1 PM | 8M97G7D | |
| 27 | 2507.5 - 2562.5 | 0.348 | 0.1 PM | 13M4G7D | |
| 27 | 2510.0 - 2560.0 | 0.344 | 0.1 PM | 17M9G7D | |
| 27 | 2502.5 - 2567.5 | 0.343 | 0.1 PM | 4M49W7D | |
| 27 | 2505.0 - 2565.0 | 0.292 | 0.1 PM | 8M96W7D | |
| 27 | 2507.5 - 2562.5 | 0.292 | 0.1 PM | 13M5W7D | |
| 27 | 2510.0 - 2560.0 | 0.288 | 0.1 PM | 17M9W7D | |
| 27 | 779.5 - 784.5 | 0.216 | 0.1 PM | 4M46G7D | |
| 27 | 782.0 - 782.0 | 0.215 | 0.1 PM | 8M92G7D | |
| 27 | 779.5 - 784.5 | 0.183 | 0.1 PM | 4M47W7D | |
| 27 | 782.0 - 782.0 | 0.107 | 0.1 PM | 8M91W7D | |
| 27 | 1710.7 - 1779.3 | 0.248 | 0.1 PM | 1M10G7D | |
| 27 | 1711.5 - 1778.5 | 0.246 | 0.1 PM | 2M70G7D | |
| 27 | 1712.5 - 1777.5 | 0.248 | 0.1 PM | 4M50G7D | |
| 27 | 1715.0 - 1775.0 | 0.251 | 0.1 PM | 8M98G7D | |
| 27 | 1717.5 - 1772.5 | 0.247 | 0.1 PM | 13M5G7D | |
| 27 | 1720.0 - 1770.0 | 0.25 | 0.1 PM | 18M0G7D | |
| 27 | 1710.7 - 1779.3 | 0.188 | 0.1 PM | 1M09W7D | |
| 27 | 1711.5 - 1778.5 | 0.187 | 0.1 PM | 2M70W7D | |
| 27 | 1712.5 - 1777.5 | 0.2 | 0.1 PM | 4M48W7D | |
| 27 | 1715.0 - 1775.0 | 0.188 | 0.1 PM | 8M48W7D | |
| 27 | 1717.5 - 1772.5 | 0.192 | 0.1 PM | 13M5W7D | |
| 27 | 1720.0 - 1770.0 | 0.19 | 0.1 PM | 18M0W7D | |
| 90 | 790.5 - 795.5 | 0.13 | 1.25 PM | 4M49G7D | |
| 90 | 793.0 - 793.0 | 0.13 | 1.25 PM | 8M95G7D | |
| 90 | 790.5 - 795.5 | 0.11 | 1.25 PM | 4M48W7D | |
| 90 | 793.0 - 793.0 | 0.11 | 1.25 PM | 8M95W7D |
| Output power is ERP for Part 22 / Part 90 and EIRP for Part 24 / Part 27. This device and its antenna(s) must be installed to provide a separation distance of at least 27 cm from all persons. End users must be informed of the final installation requirements for meeting FCC RF Exposure compliance. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD America Inc. 401 Edgewater Place Suite #500 Wakefield, MA 01880 |
Date of Grant: 03/16/2019 Application Dated: 03/15/2019 |
| Inseego Corp. |
| 9710 Scranton Road |
| Suite 200 |
| San Diego, CA 92121 |
| Attention: Roman Olmos , Staff Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PKRISGSKR3MD8800 |
| Name of Grantee: | Inseego Corp. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless Router |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.323 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.524 |
| Power output listed is conducted. This device and its antenna(s) must be installed to provide a separation distance of at least 27 cm from all persons. End users must be informed of the final installation requirements for meeting FCC RF Exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application 4ZLMfJfROKEf/JrmFPr4kg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Inseego Corp. 9710 Scranton Road Suite 200 San Diego, CA 92121 United States |
Date of Grant: 03/16/2019 Application Dated: 03/15/2019 |
| Attention: Roman Olmos , Staff Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PKRISGSKR3MD8800 |
| Name of Grantee: | Inseego Corp. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless Router |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.323 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.524 |
| Power output listed is conducted. This device and its antenna(s) must be installed to provide a separation distance of at least 27 cm from all persons. End users must be informed of the final installation requirements for meeting FCC RF Exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD America Inc. 401 Edgewater Place Suite #500 Wakefield, MA 01880 |
Date of Grant: 03/16/2019 Application Dated: 03/15/2019 |
| Inseego Corp. |
| 9710 Scranton Road |
| Suite 200 |
| San Diego, CA 92121 |
| Attention: Roman Olmos , Staff Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PKRISGSKR3MD8800 |
| Name of Grantee: | Inseego Corp. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless Router |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.609 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.005 |
| Power output listed is conducted. This device and its antenna(s) must be installed to provide a separation distance of at least 27 cm from all persons. End users must be informed of the final installation requirements for meeting FCC RF Exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application /3TnuGn3RzWNOSiAGqTtmg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Inseego Corp. 9710 Scranton Road Suite 200 San Diego, CA 92121 United States |
Date of Grant: 03/16/2019 Application Dated: 03/15/2019 |
| Attention: Roman Olmos , Staff Regulatory Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PKRISGSKR3MD8800 |
| Name of Grantee: | Inseego Corp. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless Router |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.609 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.005 |
| Power output listed is conducted. This device and its antenna(s) must be installed to provide a separation distance of at least 27 cm from all persons. End users must be informed of the final installation requirements for meeting FCC RF Exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |