FCC ID PLRAX1255
ArcXTEND Wireless Hub Access Point
by Arcwave, Inc.
Grantee Code: PLR Product Code: AX1255
Latest application date: 2005-02-16
FCC ID Device Details
| FCC ID | PLRAX1255 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | PLR |
| Product Code | AX1255 |
| Applicant Business | Arcwave, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | ArcXTEND Wireless Hub Access Point |
| Test Firm | Compliance Certification Services Inc |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5729-5813 MHz | Original Equipment | 2005-02-16 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2005-02-16 | PDF 2.6 MB |
| Internal Photos 1 of 2 | Internal Photos | 2005-02-16 | PDF 1.4 MB |
| Internal Photos 2 of 2 | Internal Photos | 2005-02-16 | PDF 859.2 KB |
| External Photos | External Photos | 2005-02-16 | PDF 274.4 KB |
| ID Label Location Info | ID Label/Location Info | 2005-02-16 | PDF 63.9 KB |
| Test Setup Photos | Test Setup Photos | 2005-02-16 | PDF 526.3 KB |
| Test Report | Test Report | 2005-02-16 | PDF 1.7 MB |
| Agent Authorization Letter | Cover Letter(s) | 2005-02-16 | PDF 1.7 MB |
| Request for Confidentiality | Cover Letter(s) | 2005-02-16 | PDF 539.9 KB |
| TCB Q and A | Cover Letter(s) | 2005-02-16 | PDF 16.5 KB |
| Antenna Specification | Parts List/Tune Up Info | 2005-02-16 | PDF 1.1 MB |
| Block Diagram Metadata only | Block Diagram | PDF 52.9 KB | |
| Schematics AX105 Metadata only | Schematics | PDF 99.7 KB | |
| Schematics AX150 Metadata only | Schematics | PDF 74.5 KB | |
| Schematics AX300 Metadata only | Schematics | PDF 113.3 KB | |
| Operational Description Metadata only | Operational Description | PDF 1.3 MB |
Application Information
| Application ID | 2u/kk5yKuFLQ3O/v2//kbg== |
|---|---|
| Final Action Date | 2005-02-16 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0009748567 |
| Model | AX1255 |
| Frequency Range | 5729-5813 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | ArcXTEND Wireless Hub Access Point |
| Responsible Party | Leon Louie, Director of Operations, llouie@arcwaveinc.com |
| Test Firm | Steve Cheng, Compliance Certification Services Inc, scheng@ccemc.com |
| TCB Email | MKUO@CCSEMC.COM |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. Professional installation is required. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 2u/kk5yKuFLQ3O/v2//kbg== | 2005-02-16 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 5729-5813 MHz | 0.0724400 | 15C |
Grants
TCB Grant - Application 2u/kk5yKuFLQ3O/v2//kbg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 02/16/2005 Application Dated: 02/16/2005 |
| Arcwave, Inc. |
| 910 Campisi Way, #1C |
| Campbell, CA 95008 |
| Attention: Leon Louie , Director of Operations |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PLRAX1255 |
| Name of Grantee: | Arcwave, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | ArcXTEND Wireless Hub Access Point |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 5729.0 - 5813.0 | 0.07244 |
| Output power listed is conducted. Professional installation is required. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application 2u/kk5yKuFLQ3O/v2//kbg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Arcwave, Inc. 910 Campisi Way, #1C Campbell, CA 95008 United States |
Date of Grant: 02/16/2005 Application Dated: 02/16/2005 |
| Attention: Leon Louie , Director of Operations |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PLRAX1255 |
| Name of Grantee: | Arcwave, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | ArcXTEND Wireless Hub Access Point |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 5729.0 - 5813.0 | 0.07244 |
| Output power listed is conducted. Professional installation is required. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |