FCC ID PQC-TRNSBV1
Range Extender for SRR measurements via WLAN
by Philips Medical Systems North America Co.
Grantee Code: PQC Product Code: TRNSBV1
Latest application date: 2018-05-09
FCC ID Device Details
| FCC ID | PQC-TRNSBV1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | PQC |
| Product Code | TRNSBV1 |
| Applicant Business | Philips Medical Systems North America Co. 🇺🇸 |
| Related Domains | |
| Equipment Class | Range Extender for SRR measurements via WLAN |
| Test Firm | CTC advanced GmbH |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 608.375-613.625 MHz | Original Equipment | 2018-05-09 |
| 5180-5240 MHz | Original Equipment | 2018-05-09 |
| 2405-2480 MHz | Original Equipment | 2018-05-09 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2018-05-09 | PDF 2.4 MB |
| Internal Photos | Internal Photos | 2018-05-09 | PDF 649 KB |
| External Photos | External Photos | 2018-05-09 | PDF 473.7 KB |
| Label | ID Label/Location Info | 2018-05-09 | PDF 208.5 KB |
| Test Setup | Test Setup Photos | 2018-05-09 | PDF 724.5 KB |
| Report (NII) DFS | Test Report | 2018-05-09 | PDF 572.5 KB |
| Report MBAN (conducted) | Test Report | 2018-05-09 | PDF 3.1 MB |
| Report MBAN (radiated) | Test Report | 2018-05-09 | PDF 4.6 MB |
| Report SRR (conducted) | Test Report | 2018-05-09 | PDF 2.6 MB |
| Report SRR (radiated) | Test Report | 2018-05-09 | PDF 2 MB |
| Report WLAN (DTS) | Test Report | 2018-05-09 | PDF 4 MB |
| Report WLAN (DTS), Annex 2, Part 1 | Test Report | 2018-05-09 | PDF 5.9 MB |
| Report WLAN (DTS), Annex 2, Part 2 | Test Report | 2018-05-09 | PDF 3.6 MB |
| Report WLAN (NII) part 1 | Test Report | 2018-05-09 | PDF 5 MB |
| Report WLAN (NII) part 2 | Test Report | 2018-05-09 | PDF 2.5 MB |
| Report WLAN (NII), Annex 1 | Test Report | 2018-05-09 | PDF 5.5 MB |
| Report WLAN (NII), Annex 2 | Test Report | 2018-05-09 | PDF 5.4 MB |
| Report WLAN (NII), Annex 3 | Test Report | 2018-05-09 | PDF 5.5 MB |
| Report WLAN (NII), Annex 4 | Test Report | 2018-05-09 | PDF 5.5 MB |
| Report WLAN (NII), Annex 5 | Test Report | 2018-05-09 | PDF 5.4 MB |
| Report WLAN (NII), Annex 6 | Test Report | 2018-05-09 | PDF 5.4 MB |
| Report WLAN (NII), Annex 7 | Test Report | 2018-05-09 | PDF 2.6 MB |
| Authorisation from Philips Healthcare US | Cover Letter(s) | 2018-05-09 | PDF 42.6 KB |
| Declaration re-use Reports | Cover Letter(s) | 2018-05-09 | PDF 127.9 KB |
| fcc-confidentiality-iv-cl-13apr18 | Cover Letter(s) | 2018-05-09 | PDF 673.6 KB |
| SAR Report | RF Exposure Info | 2018-05-09 | PDF 2.4 MB |
| SAR Report - CalData | RF Exposure Info | 2018-05-09 | PDF 3.5 MB |
| Block Diagram Metadata only | Block Diagram | PDF 212.6 KB | |
| Block Diagram WLAN Metadata only | Block Diagram | PDF 524 KB | |
| Schematics SRR Metadata only | Schematics | PDF 756.4 KB | |
| Schematics WLAN Metadata only | Schematics | PDF 350 KB | |
| Confirmation no BT (page 3) Metadata only | Operational Description | PDF 724.7 KB | |
| Operational Description Metadata only | Operational Description | PDF 589.6 KB | |
| WLAN SW Security Metadata only | Operational Description | PDF 66.7 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 384.8 KB | |
| Tune-up Metadata only | Parts List/Tune Up Info | PDF 166.6 KB |
Application Information
| Application ID | sMQl06tJvfCw9nVW5EbiTg== |
|---|---|
| Final Action Date | 2018-05-09 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0017950635 |
| Model | TRNSBV1 |
| Frequency Range | 608.375-613.625 MHz |
| Equipment Class | TNT - Licensed Non-Broadcast Transmitter Worn on Body |
| Device Description | Range Extender for SRR measurements via WLAN |
| Responsible Party | Delroy Smith, Principal Scientist / Project Leader, delroy.smith@philips.com |
| Test Firm | Gerald Schmidt, CTC advanced GmbH, mail@ctcadvanced.com |
| TCB Email | TCB@ctcadvanced.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
| Grant Comments | Output power listed is ERP for below 1GHz and EIRP for above 1GHz. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| sMQl06tJvfCw9nVW5EbiTg== | 2018-05-09 | Original Equipment |
| jw0K7yj6MVVchYSKVXN8Gg== | 2018-05-09 | Original Equipment |
| c86V0mIQ0ObupEfwhnce6w== | 2018-05-09 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 608.375-613.625 MHz | 0.0002 | 12Hz | 111KF1D | 95H | |
| 2363-2387 MHz | 0.0009 | 5.5ppm | 2M56GXD | 95I | |
| 2392-2397 MHz | 0.0011 | 5.4ppm | 2M60GXD | 95I | |
| 2405-2480 MHz | 0.001 | 15C | CC | ||
| 2412-2462 MHz | 0.0204 | 15C | CC | ||
| 5180-5240 MHz | 0.0129 | 15E | CC | ||
| 5260-5320 MHz | 0.0145 | 15E | CC | ||
| 5500-5580 MHz | 0.0182 | 15E | CC | ||
| 5660-5700 MHz | 0.0162 | 15E | CC | ||
| 5745-5825 MHz | 0.0129 | 15E | CC |
Grants
TCB Grant - Application sMQl06tJvfCw9nVW5EbiTg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CTC advanced GmbH Untertuerkheimer Strasse 6-10 66117 Saarbruecken, Germany |
Date of Grant: 05/09/2018 Application Dated: 04/23/2018 |
| Philips Medical Systems North America Co. |
| 3000 Minuteman Road |
| Andover, MA 01810-1099 |
| Attention: Delroy Smith , Principal Scientist / Project Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PQC-TRNSBV1 |
| Name of Grantee: | Philips Medical Systems North America Co. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Worn on Body |
| Notes: | Range Extender for SRR measurements via WLAN |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95H | 608.375 - 613.625 | 0.0002 | 12.0 Hz | 111KF1D | |
| 95I | 2363.0 - 2387.0 | 0.0009 | 5.5 PM | 2M56GXD | |
| 95I | 2392.0 - 2397.0 | 0.0011 | 5.4 PM | 2M60GXD |
| Output power listed is ERP for below 1GHz and EIRP for above 1GHz. |
EAS Grant - Application sMQl06tJvfCw9nVW5EbiTg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Philips Medical Systems North America Co. 3000 Minuteman Road Andover, MA 01810-1099 United States |
Date of Grant: 05/09/2018 Application Dated: 04/23/2018 |
| Attention: Delroy Smith , Principal Scientist / Project Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PQC-TRNSBV1 |
| Name of Grantee: | Philips Medical Systems North America Co. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Worn on Body |
| Notes: | Range Extender for SRR measurements via WLAN |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95H | 608.375 - 613.625 | 0.0002 | 12.0 Hz | 111KF1D | |
| 95I | 2363.0 - 2387.0 | 0.0009 | 5.5 PM | 2M56GXD | |
| 95I | 2392.0 - 2397.0 | 0.0011 | 5.4 PM | 2M60GXD |
| Output power listed is ERP for below 1GHz and EIRP for above 1GHz. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CTC advanced GmbH Untertuerkheimer Strasse 6-10 66117 Saarbruecken, Germany |
Date of Grant: 05/09/2018 Application Dated: 04/23/2018 |
| Philips Medical Systems North America Co. |
| 3000 Minuteman Road |
| Andover, MA 01810-1099 |
| Attention: Delroy Smith , Principal Scientist / Project Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PQC-TRNSBV1 |
| Name of Grantee: | Philips Medical Systems North America Co. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Range Extender for SRR measurements via WLAN |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0129 | ||
| CC | 15E | 5260.0 - 5320.0 | 0.0145 | ||
| CC | 15E | 5500.0 - 5580.0 | 0.0182 | ||
| CC | 15E | 5660.0 - 5700.0 | 0.0162 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.0129 |
| Output power listed is conducted. SAR compliance for body-worn operation is based on a separation distance of 10 mm between the front side of unit and the body of the user and 0mm for all other sides. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.743W/kg and 0.888W/kg respectively |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application jw0K7yj6MVVchYSKVXN8Gg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Philips Medical Systems North America Co. 3000 Minuteman Road Andover, MA 01810-1099 United States |
Date of Grant: 05/09/2018 Application Dated: 04/23/2018 |
| Attention: Delroy Smith , Principal Scientist / Project Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PQC-TRNSBV1 |
| Name of Grantee: | Philips Medical Systems North America Co. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Range Extender for SRR measurements via WLAN |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0129 | ||
| CC | 15E | 5260.0 - 5320.0 | 0.0145 | ||
| CC | 15E | 5500.0 - 5580.0 | 0.0182 | ||
| CC | 15E | 5660.0 - 5700.0 | 0.0162 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.0129 |
| Output power listed is conducted. SAR compliance for body-worn operation is based on a separation distance of 10 mm between the front side of unit and the body of the user and 0mm for all other sides. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.743W/kg and 0.888W/kg respectively |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CTC advanced GmbH Untertuerkheimer Strasse 6-10 66117 Saarbruecken, Germany |
Date of Grant: 05/09/2018 Application Dated: 04/23/2018 |
| Philips Medical Systems North America Co. |
| 3000 Minuteman Road |
| Andover, MA 01810-1099 |
| Attention: Delroy Smith , Principal Scientist / Project Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PQC-TRNSBV1 |
| Name of Grantee: | Philips Medical Systems North America Co. |
| Equipment Class: | Digital Transmission System |
| Notes: | Range Extender for SRR measurements via WLAN |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2405.0 - 2480.0 | 0.001 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.0204 |
| Output power listed is conducted. SAR compliance for body-worn operation is based on a separation distance of 10 mm between the front side of unit and the body of the user and 0mm for all other sides. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.743W/kg and 0.888W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application c86V0mIQ0ObupEfwhnce6w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Philips Medical Systems North America Co. 3000 Minuteman Road Andover, MA 01810-1099 United States |
Date of Grant: 05/09/2018 Application Dated: 04/23/2018 |
| Attention: Delroy Smith , Principal Scientist / Project Leader |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | PQC-TRNSBV1 |
| Name of Grantee: | Philips Medical Systems North America Co. |
| Equipment Class: | Digital Transmission System |
| Notes: | Range Extender for SRR measurements via WLAN |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2405.0 - 2480.0 | 0.001 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.0204 |
| Output power listed is conducted. SAR compliance for body-worn operation is based on a separation distance of 10 mm between the front side of unit and the body of the user and 0mm for all other sides. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.743W/kg and 0.888W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |