FCC ID SRQ-MF975U

CDMA/LTE Ufi

by ZTE Corporation

Grantee Code: SRQ   Product Code: MF975U
Latest application date: 2015-09-11

FCC ID Device Details

FCC IDSRQ-MF975U
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSRQ
Product CodeMF975U
Applicant BusinessZTE Corporation 🇨🇳
Related Domains zte.com.cn sporton.com.tw
Equipment ClassCDMA/LTE Ufi
Test FirmSPORTON International(KunShan) Inc

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2015-09-11
2412-2462 MHzOriginal Equipment2015-09-11
699.7-715.3 MHzOriginal Equipment2015-09-11

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2016-03-10PDF 1.3 MB
Internal photoInternal Photos2016-03-10PDF 3.2 MB
External photoExternal Photos2016-03-10PDF 1.2 MB
ID LabelID Label/Location Info2015-09-11PDF 174.9 KB
Label location infoID Label/Location Info2015-09-11PDF 34.8 KB
Test setup photo_DTSTest Setup Photos2016-03-10PDF 1.1 MB
Test setup photo_NII_5G Band 1Test Setup Photos2016-03-10PDF 1.4 MB
Test setup photo_NII_5G Band 4Test Setup Photos2016-03-10PDF 1,013.8 KB
Test setup photo_PCB_CDMATest Setup Photos2016-03-10PDF 872 KB
Test setup photo_PCB_LTETest Setup Photos2016-03-10PDF 421.9 KB
Test setup photo_SARTest Setup Photos2016-03-10PDF 292.3 KB
Test report_DTSTest Report2015-09-11PDF 1.5 MB
Test report_NII_5G Band 1Test Report2015-09-11PDF 795.2 KB
Test report_NII_5G Band 4Test Report2015-09-11PDF 771.8 KB
Test report_PCB_CDMATest Report2015-09-11PDF 465.3 KB
Test report_PCB_LTE_Part 1Test Report2015-09-11PDF 5.6 MB
Test report_PCB_LTE_Part 2Test Report2015-09-11PDF 5.4 MB
Test report_PCB_LTE_Part 3Test Report2015-09-11PDF 5.5 MB
Test report_SAR_Appendix C1RF Exposure Info2015-09-11PDF 4.9 MB
Test report_SAR_Appendix C2RF Exposure Info2015-09-11PDF 3.1 MB
Test report_SAR_Report & Appendix A&BRF Exposure Info2015-09-11PDF 2.8 MB
Test report_SAR_report & Appendix A&BRF Exposure Info2015-09-11PDF 2.8 MB
5GHz declaration letterCover Letter(s)2015-09-11PDF 76.6 KB
Declaration of authorizationCover Letter(s)2015-09-11PDF 12.3 KB
USB functionCover Letter(s)2015-09-11PDF 12 KB
confidentialityCover Letter(s)2015-09-11PDF 17.3 KB
Block diagram Metadata onlyBlock DiagramPDF 133.4 KB
Schematics Metadata onlySchematicsPDF 901 KB
Device SW Security Statement Metadata onlyOperational DescriptionPDF 56.2 KB
Operational description Metadata onlyOperational DescriptionPDF 542 KB
Parts list (BOM) Metadata onlyParts List/Tune Up InfoPDF 87.7 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 102 KB

Application Information

Application IDrSfEWoSz5X+dQvCNZ0KhVw==
Final Action Date2015-09-11
Application PurposeOriginal Equipment
Applicant FRN0022602015
ModelMF975U
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionCDMA/LTE Ufi
Responsible PartyChaijue Ding, Certification Manager, ding.chaijue@zte.com.cn , +86-13764330709
AgentMichael Michael Michael, SPORTON INTERNATIONAL (KUNSHAN) INC, Michael@Sporton.com.tw , 86-0512-5790-0158
Technical ContactMichael Lin, SPORTON INTERNATIONAL (KUNSHAN) INC, Michael@Sporton.com.tw , 86-0512-5790-0158
Non-Technical ContactMichael Lin, SPORTON INTERNATIONAL (KUNSHAN) INC, Michael@Sporton.com.tw , 86-0512-5790-0158
Test FirmMichael Lin, SPORTON International(KunShan) Inc, Michael@sporton.com.tw , 86-512-57900158
TCB Emailcertification@telefication.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date03/10/2016
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output is conducted. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm separation between the device and the user's body. End users must be informed of the body requirements for satisfying RF Exposure compliance. The highest reported SAR values for body and simultaneous transmission use conditions are 0.39 W/kg, and 1.58 W/kg, respectively. This device has 20/40/80 MHz bandwidth modes.

Applications

Application IDDatePurpose
rSfEWoSz5X+dQvCNZ0KhVw==2015-09-11Original Equipment
ZThWiEe8sTl5UcGq0/f6aA==2015-09-11Original Equipment
8tauD2piH35oxFBkpV9eXg==2015-09-11Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
699.7-715.3 MHz0.1080.0184ppm9M09G7D27
699.7-715.3 MHz0.0950.0184ppm9M03W7D27
699.7-715.3 MHz0.1140.0184ppm2M73G7D27
699.7-715.3 MHz0.0970.0184ppm2M73W7D27
779.5-784.5 MHz0.1350.0448ppm9M13G7D27
779.5-784.5 MHz0.1180.0448ppm9M05W7D27
779.5-784.5 MHz0.1490.0448ppm4M50G7D27
824.7-848.3 MHz0.1110.0155ppm2M73G7D22H
824.7-848.3 MHz0.090.0155ppm2M73W7D22H
824.7-848.3 MHz0.0990.0155ppm9M07G7D22H
824.7-848.3 MHz0.0850.0155ppm9M05W7D22H
1710.7-1754.3 MHz0.4610.0107ppm18M4G7D27
1710.7-1754.3 MHz0.4830.0107ppm18M5W7D27
1710.7-1754.3 MHz0.4650.0107ppm13M5G7D27
1850.7-1909.3 MHz0.6140.0085ppm18M5G7D24E
1850.7-1909.3 MHz0.5320.0085ppm18M5W7D24E
1851.25-1908.75 MHz0.3410.0239ppm1M28F9W24E
2412-2462 MHz0.227000015CCC, MO
5180-5240 MHz0.0115E38, CC, MO
5745-5825 MHz0.01215E38, CC, MO

Grants

TCB Grant - Application ZThWiEe8sTl5UcGq0/f6aA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 09/11/2015

Application Dated: 09/11/2015
ZTE Corporation
ZTE Plaza, Keji Road South
Shenzhen,
China
 
Attention: Chaijue Ding , Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SRQ-MF975U
Name of Grantee:  ZTE Corporation
Equipment Class: Digital Transmission System
Notes: CDMA/LTE Ufi
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.227  

Power Output is conducted. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm separation between the device and the user's body. End users must be informed of the body requirements for satisfying RF Exposure compliance. The highest reported SAR values for body and simultaneous transmission use conditions are 0.16 W/kg, and 1.50 W/kg, respectively.

This device has 20/40 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application ZThWiEe8sTl5UcGq0/f6aA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ZTE Corporation
ZTE Plaza, Keji Road South
Shenzhen,
China
  Date of Grant: 09/11/2015

Application Dated: 09/11/2015
 
Attention: Chaijue Ding , Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SRQ-MF975U
Name of Grantee:  ZTE Corporation
Equipment Class: Digital Transmission System
Notes: CDMA/LTE Ufi
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.227  

Power Output is conducted. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm separation between the device and the user's body. End users must be informed of the body requirements for satisfying RF Exposure compliance. The highest reported SAR values for body and simultaneous transmission use conditions are 0.16 W/kg, and 1.50 W/kg, respectively.

This device has 20/40 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application rSfEWoSz5X+dQvCNZ0KhVw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 09/11/2015

Application Dated: 09/11/2015
ZTE Corporation
ZTE Plaza, Keji Road South
Shenzhen,
China
 
Attention: Chaijue Ding , Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SRQ-MF975U
Name of Grantee:  ZTE Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: CDMA/LTE Ufi
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.01  
38 CC MO 15E 5745.0  -  5825.0 0.012  

Power Output is conducted. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm separation between the device and the user's body. End users must be informed of the body requirements for satisfying RF Exposure compliance.

The highest reported SAR values for body and simultaneous transmission use conditions are 0.39 W/kg, and 1.58 W/kg, respectively.

This device has 20/40/80 MHz bandwidth modes.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application rSfEWoSz5X+dQvCNZ0KhVw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ZTE Corporation
ZTE Plaza, Keji Road South
Shenzhen,
China
  Date of Grant: 09/11/2015

Application Dated: 09/11/2015
 
Attention: Chaijue Ding , Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SRQ-MF975U
Name of Grantee:  ZTE Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: CDMA/LTE Ufi
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.01  
38 CC MO 15E 5745.0  -  5825.0 0.012  

Power Output is conducted. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm separation between the device and the user's body. End users must be informed of the body requirements for satisfying RF Exposure compliance.

The highest reported SAR values for body and simultaneous transmission use conditions are 0.39 W/kg, and 1.58 W/kg, respectively.

This device has 20/40/80 MHz bandwidth modes.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application 8tauD2piH35oxFBkpV9eXg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 09/11/2015

Application Dated: 09/11/2015
ZTE Corporation
ZTE Plaza, Keji Road South
Shenzhen,
China
 
Attention: Chaijue Ding , Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SRQ-MF975U
Name of Grantee:  ZTE Corporation
Equipment Class: PCS Licensed Transmitter
Notes: CDMA/LTE Ufi
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.161 0.0454  PM 1M28F9W
24E 1851.25  -  1908.75 0.341 0.0239  PM 1M28F9W
24E 1850.7  -  1909.3 0.614 0.0085  PM 18M5G7D
24E 1850.7  -  1909.3 0.532 0.0085  PM 18M5W7D
27 1710.7  -  1754.3 0.461 0.0107  PM 18M4G7D
27 1710.7  -  1754.3 0.483 0.0107  PM 18M5W7D
27 1710.7  -  1754.3 0.465 0.0107  PM 13M5G7D
22H 824.7  -  848.3 0.099 0.0155  PM 9M07G7D
22H 824.7  -  848.3 0.085 0.0155  PM 9M05W7D
22H 824.7  -  848.3 0.111 0.0155  PM 2M73G7D
22H 824.7  -  848.3 0.09 0.0155  PM 2M73W7D
27 699.7  -  715.3 0.108 0.0184  PM 9M09G7D
27 699.7  -  715.3 0.095 0.0184  PM 9M03W7D
27 699.7  -  715.3 0.114 0.0184  PM 2M73G7D
27 699.7  -  715.3 0.097 0.0184  PM 2M73W7D
27 779.5  -  784.5 0.135 0.0448  PM 9M13G7D
27 779.5  -  784.5 0.118 0.0448  PM 9M05W7D
27 779.5  -  784.5 0.149 0.0448  PM 4M50G7D

Power Output is ERP for part 22 and 27 and EIRP for Part 24 and 27. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm separation between the device and the user's body. End users must be informed of the body requirements for satisfying RF Exposure compliance.

The highest reported SAR values for body and simultaneous transmission use conditions are 1.45 W/kg, and 1.58 W/kg, respectively.


EAS Grant - Application 8tauD2piH35oxFBkpV9eXg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ZTE Corporation
ZTE Plaza, Keji Road South
Shenzhen,
China
  Date of Grant: 09/11/2015

Application Dated: 09/11/2015
 
Attention: Chaijue Ding , Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SRQ-MF975U
Name of Grantee:  ZTE Corporation
Equipment Class: PCS Licensed Transmitter
Notes: CDMA/LTE Ufi
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.161 0.0454  PM 1M28F9W
24E 1851.25  -  1908.75 0.341 0.0239  PM 1M28F9W
24E 1850.7  -  1909.3 0.614 0.0085  PM 18M5G7D
24E 1850.7  -  1909.3 0.532 0.0085  PM 18M5W7D
27 1710.7  -  1754.3 0.461 0.0107  PM 18M4G7D
27 1710.7  -  1754.3 0.483 0.0107  PM 18M5W7D
27 1710.7  -  1754.3 0.465 0.0107  PM 13M5G7D
22H 824.7  -  848.3 0.099 0.0155  PM 9M07G7D
22H 824.7  -  848.3 0.085 0.0155  PM 9M05W7D
22H 824.7  -  848.3 0.111 0.0155  PM 2M73G7D
22H 824.7  -  848.3 0.09 0.0155  PM 2M73W7D
27 699.7  -  715.3 0.108 0.0184  PM 9M09G7D
27 699.7  -  715.3 0.095 0.0184  PM 9M03W7D
27 699.7  -  715.3 0.114 0.0184  PM 2M73G7D
27 699.7  -  715.3 0.097 0.0184  PM 2M73W7D
27 779.5  -  784.5 0.135 0.0448  PM 9M13G7D
27 779.5  -  784.5 0.118 0.0448  PM 9M05W7D
27 779.5  -  784.5 0.149 0.0448  PM 4M50G7D

Power Output is ERP for part 22 and 27 and EIRP for Part 24 and 27. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm separation between the device and the user's body. End users must be informed of the body requirements for satisfying RF Exposure compliance.

The highest reported SAR values for body and simultaneous transmission use conditions are 1.45 W/kg, and 1.58 W/kg, respectively.



Mail To: