FCC ID TBU-X8KPTPP
Pixavi Thermal/Pixavi Phone
by BARTEC
Grantee Code: TBU Product Code: X8KPTPP
Latest application date: 2022-06-28
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Class II permissive change or modification of presently authorized equipment | 2022-06-28 |
| 2402-2480 MHz | Original Equipment | 2022-05-29 |
| 2565-2645 MHz | Original Equipment | 2022-05-29 |
| 2412-2462 MHz | Original Equipment | 2022-05-29 |
| 13.56 MHz | Original Equipment | 2022-05-29 |
| 5500-5700 MHz | Original Equipment | 2022-05-29 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2022-11-26 | PDF 152.1 KB |
| User manual | Users Manual | 2022-11-26 | PDF 152.1 KB |
| Internal Photo | Internal Photos | 2022-11-26 | PDF 2.6 MB |
| Internal Photos | Internal Photos | 2022-11-26 | PDF 2.6 MB |
| Internal photos | Internal Photos | 2022-11-26 | PDF 2.6 MB |
| External photos | External Photos | 2022-12-24 | PDF 1.2 MB |
| External Photo | External Photos | 2022-11-26 | PDF 1.2 MB |
| External Photos | External Photos | 2022-11-26 | PDF 1.2 MB |
| External photos | External Photos | 2022-11-26 | PDF 1.2 MB |
| label location | ID Label/Location Info | 2022-06-28 | PDF 157.9 KB |
| Label and location | ID Label/Location Info | 2022-05-29 | PDF 157.9 KB |
| Label_Location | ID Label/Location Info | 2022-05-29 | PDF 157.9 KB |
| Test Setup Photos SAR | Test Setup Photos | 2022-12-24 | PDF 680.6 KB |
| Test Setup photo | Test Setup Photos | 2022-12-24 | PDF 579 KB |
| Test setup photo | Test Setup Photos | 2022-11-26 | PDF 669.3 KB |
| Test setup photo | Test Setup Photos | 2022-11-26 | PDF 405.7 KB |
| Test setup photoSAR | Test Setup Photos | 2022-11-26 | PDF 942.2 KB |
| Test Report | Test Report | 2022-06-28 | PDF 5.7 MB |
| Test Report | Test Report | 2022-05-29 | PDF 2.5 MB |
| Test Report | Test Report | 2022-05-29 | PDF 4.4 MB |
| Test Report | Test Report | 2022-05-29 | PDF 4.5 MB |
| Test Report | Test Report | 2022-05-29 | PDF 5.8 MB |
| Test Report | Test Report | 2022-05-29 | PDF 4.7 MB |
| Test Report SAR | RF Exposure Info | 2022-05-29 | PDF 2.9 MB |
| Test Report SAR | RF Exposure Info | 2022-05-29 | PDF 3.9 MB |
| Agent Authorization Rev 1.0 | Cover Letter(s) | 2022-06-28 | PDF 47.7 KB |
| Difference Description | Cover Letter(s) | 2022-06-28 | PDF 75.4 KB |
| FCC AuthorizationLetter for STS Lab | Cover Letter(s) | 2022-06-28 | PDF 284.9 KB |
| FCC Class II PC request letter Rev1.1 | Cover Letter(s) | 2022-06-28 | PDF 83.7 KB |
| FCC Software Configuration Control Declaration Rev1.1 | Cover Letter(s) | 2022-06-28 | PDF 107.6 KB |
| FCC_Long Term Only Confidentiality Request Rev4.0 | Cover Letter(s) | 2022-06-28 | PDF 85.6 KB |
| Agent Authorization Rev 1.0 | Cover Letter(s) | 2022-05-29 | PDF 47.7 KB |
| Declaration of identity | Cover Letter(s) | 2022-05-29 | PDF 75.5 KB |
| Difference Description | Cover Letter(s) | 2022-05-29 | PDF 75.5 KB |
| Differences Description | Cover Letter(s) | 2022-05-29 | PDF 75.5 KB |
| FCC Short & Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 2022-05-29 | PDF 85.6 KB |
| FCC Software Configuration Control Declaration Rev1.1 | Cover Letter(s) | 2022-05-29 | PDF 107.6 KB |
| FCC_Short Long Term Confidentiality Request | Cover Letter(s) | 2022-05-29 | PDF 85.6 KB |
| FCC_Short Long Term Confidentiality Request_EZDS_rev2 | Cover Letter(s) | 2022-05-29 | PDF 85.6 KB |
| SAR Calibration Report | RF Exposure Info | 2022-06-28 | PDF 2.9 MB |
| Test Report SAR | RF Exposure Info | 2022-06-28 | PDF 4.1 MB |
| SAR Calibration Report | RF Exposure Info | 2022-05-29 | PDF 2.9 MB |
| BLOCK Metadata only | Block Diagram | PDF 149.1 KB | |
| Block Metadata only | Block Diagram | PDF 149.1 KB | |
| Block Diagram Metadata only | Block Diagram | PDF 149.1 KB | |
| SCH Metadata only | Schematics | PDF 848.1 KB | |
| OP Metadata only | Operational Description | PDF 83.2 KB | |
| Operation Description Metadata only | Operational Description | PDF 83.2 KB | |
| SOFTWARESECURITYREQUIREMENTSFORU-NIIDEVICES Metadata only | SDR Software/Security Inf | PDF 237.2 KB | |
| Software Security Requirements For U-NII Devices Metadata only | SDR Software/Security Inf | PDF 236.8 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 532.3 KB | |
| Tune up procedure Metadata only | Parts List/Tune Up Info | PDF 132 KB |
Application Information
| Application ID | 7ZSy5Dgu5LqkZNzb6rqy7g== |
|---|---|
| Final Action Date | 2022-06-28 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0013483649 |
| Model | X8KPTPP |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Pixavi Thermal/Pixavi Phone |
| Responsible Party | Benedikt Eckert, benedikt.eckert@bartec.de |
| Technical Contact | BARTEC, benedikt.eckert@bartec.de |
| Test Firm | Bovey Yang, SHENZHEN STS TEST SERVICES CO.,LTD., Bovey@stsapp.com |
| TCB Email | certification@micomlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 12/24/2022 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR head, body-worn, hotspot and simultaneous transmission use conditions is 0.63W/kg, 0.16W/kg, 0.16W/kg and 1.36W/kg respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 7ZSy5Dgu5LqkZNzb6rqy7g== | 2022-06-28 | Class II permissive change or modification of presently authorized equipment |
| yNkr1PbFKwhBD0UH3hFu5g== | 2022-05-29 | Original Equipment |
| f9wfMS9Yri9HbwW0OvHu4Q== | 2022-05-29 | Original Equipment |
| UOdUn1/e0gUY6IH63omvvQ== | 2022-05-29 | Original Equipment |
| FATBobcLebMjAIgOQsDTsA== | 2022-05-29 | Original Equipment |
| 4KEUPx/1ijHLPhbZdG7PwQ== | 2022-05-29 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 13.56 MHz | 15C | CC | |||
| 673-688 MHz | 0.1052 | 0.045ppm | 18M0G7D | 27 | |
| 673-688 MHz | 0.1026 | 0.045ppm | 18M0W7D | 27 | |
| 704-711 MHz | 0.1023 | 0.049ppm | 8M94G7D | 27 | |
| 704-711 MHz | 0.1009 | 0.049ppm | 8M94W7D | 27 | |
| 709-711 MHz | 0.103 | 0.049ppm | 8M93G7D | 27 | |
| 709-711 MHz | 0.1016 | 0.049ppm | 8M94W7D | 27 | |
| 782 MHz | 0.0887 | 0.047ppm | 8M94G7D | 27 | |
| 782 MHz | 0.0863 | 0.047ppm | 8M94W7D | 27 | |
| 793 MHz | 0.0975 | 0.045ppm | 8M94G7D | 27 | |
| 793 MHz | 0.0957 | 0.045ppm | 8M92W7D | 27 | |
| 819 MHz | 0.0968 | 0.013ppm | 8M92G7D | 9 | |
| 819 MHz | 0.0953 | 0.013ppm | 8M91W7D | 9 | |
| 829-844 MHz | 0.1045 | 0.051ppm | 8M95G7D | 22H | |
| 829-844 MHz | 0.1026 | 0.051ppm | 8M95W7D | 22H | |
| 831.5-841.5 MHz | 0.1107 | 0.021ppm | 13M5G7D | 22H | |
| 831.5-841.5 MHz | 0.1099 | 0.021ppm | 13M5W7D | 22H | |
| 1720-1770 MHz | 0.1866 | 0.021ppm | 17M9G7D | 27 | |
| 1720-1770 MHz | 0.1824 | 0.021ppm | 17M9W7D | 27 | |
| 1720-1745 MHz | 0.1945 | 0.017ppm | 17M9G7D | 27 | |
| 1720-1745 MHz | 0.1932 | 0.017ppm | 17M9W7D | 27 | |
| 1860-1905 MHz | 0.1923 | 0.017ppm | 18M0G7D | 24E | |
| 1860-1905 MHz | 0.1875 | 0.017ppm | 18M0W7D | 24E | |
| 1860-1900 MHz | 0.191 | 0.019ppm | 17M9G7D | 24E | |
| 1860-1900 MHz | 0.1866 | 0.019ppm | 17M9W7D | 24E | |
| 2402-2480 MHz | 0.0011 | 15C | CC | ||
| 2402-2480 MHz | 0.0111000 | 15C | CC | ||
| 2412-2462 MHz | 0.0796 | 15C | CC | ||
| 2510-2560 MHz | 0.1734 | 0.014ppm | 17M9G7D | 27 | |
| 2510-2560 MHz | 0.171 | 0.014ppm | 17M9W7D | 27 | |
| 2565-2645 MHz | 0.173 | 0.019ppm | 17M9G7D | 27 | |
| 2565-2645 MHz | 0.1706 | 0.019ppm | 17M9W7D | 27 | |
| 5180-5240 MHz | 0.0206 | 15E | CC | ||
| 5260-5320 MHz | 0.0211 | 15E | CC, ND | ||
| 5500-5700 MHz | 0.0246 | 15E | CC, ND | ||
| 5745-5825 MHz | 0.0034 | 15E | CC |
Grants
TCB Grant - Application yNkr1PbFKwhBD0UH3hFu5g==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 05/29/2022 Application Dated: 05/29/2022 |
| BARTEC |
| Max-Eyth-Strasse 16 |
| Bad Mergentheim, 97980 Germany |
| Attention: Benedikt Eckert |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TBU-X8KPTPP |
| Name of Grantee: | BARTEC |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Pixavi Thermal/Pixavi Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0111 |
| Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR head, body-worn, hotspot and simultaneous transmission use conditions is 0.03W/kg, 0.02W/kg, 0.02W/kg and 1.36W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application yNkr1PbFKwhBD0UH3hFu5g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
BARTEC Max-Eyth-Strasse 16 Bad Mergentheim, 97980 Germany |
Date of Grant: 05/29/2022 Application Dated: 05/29/2022 |
| Attention: Benedikt Eckert |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TBU-X8KPTPP |
| Name of Grantee: | BARTEC |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Pixavi Thermal/Pixavi Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0111 |
| Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR head, body-worn, hotspot and simultaneous transmission use conditions is 0.03W/kg, 0.02W/kg, 0.02W/kg and 1.36W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 05/29/2022 Application Dated: 05/29/2022 |
| BARTEC |
| Max-Eyth-Strasse 16 |
| Bad Mergentheim, 97980 Germany |
| Attention: Benedikt Eckert |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TBU-X8KPTPP |
| Name of Grantee: | BARTEC |
| Equipment Class: | Digital Transmission System |
| Notes: | Pixavi Thermal/Pixavi Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0011 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.0796 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR head, body-worn, hotspot and simultaneous transmission use conditions is 0.11W/kg, 0.05W/kg, 0.05W/kg and 1.36W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application UOdUn1/e0gUY6IH63omvvQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
BARTEC Max-Eyth-Strasse 16 Bad Mergentheim, 97980 Germany |
Date of Grant: 05/29/2022 Application Dated: 05/29/2022 |
| Attention: Benedikt Eckert |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TBU-X8KPTPP |
| Name of Grantee: | BARTEC |
| Equipment Class: | Digital Transmission System |
| Notes: | Pixavi Thermal/Pixavi Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0011 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.0796 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR head, body-worn, hotspot and simultaneous transmission use conditions is 0.11W/kg, 0.05W/kg, 0.05W/kg and 1.36W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 05/29/2022 Application Dated: 05/29/2022 |
| BARTEC |
| Max-Eyth-Strasse 16 |
| Bad Mergentheim, 97980 Germany |
| Attention: Benedikt Eckert |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TBU-X8KPTPP |
| Name of Grantee: | BARTEC |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Pixavi Thermal/Pixavi Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 13.56 - 13.56 |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application FATBobcLebMjAIgOQsDTsA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
BARTEC Max-Eyth-Strasse 16 Bad Mergentheim, 97980 Germany |
Date of Grant: 05/29/2022 Application Dated: 05/29/2022 |
| Attention: Benedikt Eckert |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TBU-X8KPTPP |
| Name of Grantee: | BARTEC |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Pixavi Thermal/Pixavi Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 13.56 - 13.56 |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 05/29/2022 Application Dated: 05/29/2022 |
| BARTEC |
| Max-Eyth-Strasse 16 |
| Bad Mergentheim, 97980 Germany |
| Attention: Benedikt Eckert |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TBU-X8KPTPP |
| Name of Grantee: | BARTEC |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | Pixavi Thermal/Pixavi Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1852.4 - 1907.6 | 0.1033 | 0.019 PM | 4M14F9W | |
| 27 | 1712.4 - 1752.6 | 0.1236 | 0.019 PM | 4M14F9W | |
| 22H | 826.4 - 846.6 | 0.0889 | 0.042 PM | 4M1749W | |
| 24E | 1860.0 - 1900.0 | 0.191 | 0.019 PM | 17M9G7D | |
| 24E | 1860.0 - 1900.0 | 0.1866 | 0.019 PM | 17M9W7D | |
| 27 | 1720.0 - 1745.0 | 0.1945 | 0.017 PM | 17M9G7D | |
| 27 | 1720.0 - 1745.0 | 0.1932 | 0.017 PM | 17M9W7D | |
| 22H | 829.0 - 844.0 | 0.1045 | 0.051 PM | 8M95G7D | |
| 22H | 829.0 - 844.0 | 0.1026 | 0.051 PM | 8M95W7D | |
| 27 | 2510.0 - 2560.0 | 0.1734 | 0.014 PM | 17M9G7D | |
| 27 | 2510.0 - 2560.0 | 0.171 | 0.014 PM | 17M9W7D | |
| 27 | 704.0 - 711.0 | 0.1023 | 0.049 PM | 8M94G7D | |
| 27 | 704.0 - 711.0 | 0.1009 | 0.049 PM | 8M94W7D | |
| 27 | 782.0 - 782.0 | 0.0887 | 0.047 PM | 8M94G7D | |
| 27 | 782.0 - 782.0 | 0.0863 | 0.047 PM | 8M94W7D | |
| 27 | 793.0 - 793.0 | 0.0975 | 0.045 PM | 8M94G7D | |
| 27 | 793.0 - 793.0 | 0.0957 | 0.045 PM | 8M92W7D | |
| 27 | 709.0 - 711.0 | 0.103 | 0.049 PM | 8M93G7D | |
| 27 | 709.0 - 711.0 | 0.1016 | 0.049 PM | 8M94W7D | |
| 24E | 1860.0 - 1905.0 | 0.1923 | 0.017 PM | 18M0G7D | |
| 24E | 1860.0 - 1905.0 | 0.1875 | 0.017 PM | 18M0W7D | |
| 22H | 831.5 - 841.5 | 0.1107 | 0.021 PM | 13M5G7D | |
| 22H | 831.5 - 841.5 | 0.1099 | 0.021 PM | 13M5W7D | |
| 90 | 819.0 - 819.0 | 0.0968 | 0.013 PM | 8M92G7D | |
| 90 | 819.0 - 819.0 | 0.0953 | 0.013 PM | 8M91W7D | |
| 27 | 2565.0 - 2645.0 | 0.173 | 0.019 PM | 17M9G7D | |
| 27 | 2565.0 - 2645.0 | 0.1706 | 0.019 PM | 17M9W7D | |
| 27 | 1720.0 - 1770.0 | 0.1866 | 0.021 PM | 17M9G7D | |
| 27 | 1720.0 - 1770.0 | 0.1824 | 0.021 PM | 17M9W7D | |
| 27 | 673.0 - 688.0 | 0.1052 | 0.045 PM | 18M0G7D | |
| 27 | 673.0 - 688.0 | 0.1026 | 0.045 PM | 18M0W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR head, body-worn, hotspot and simultaneous transmission use conditions is 0.35W/kg, 1.20W/kg, 1.20W/kg and 1.36W/kg respectively. |
EAS Grant - Application f9wfMS9Yri9HbwW0OvHu4Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
BARTEC Max-Eyth-Strasse 16 Bad Mergentheim, 97980 Germany |
Date of Grant: 05/29/2022 Application Dated: 05/29/2022 |
| Attention: Benedikt Eckert |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TBU-X8KPTPP |
| Name of Grantee: | BARTEC |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | Pixavi Thermal/Pixavi Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1852.4 - 1907.6 | 0.1033 | 0.019 PM | 4M14F9W | |
| 27 | 1712.4 - 1752.6 | 0.1236 | 0.019 PM | 4M14F9W | |
| 22H | 826.4 - 846.6 | 0.0889 | 0.042 PM | 4M1749W | |
| 24E | 1860.0 - 1900.0 | 0.191 | 0.019 PM | 17M9G7D | |
| 24E | 1860.0 - 1900.0 | 0.1866 | 0.019 PM | 17M9W7D | |
| 27 | 1720.0 - 1745.0 | 0.1945 | 0.017 PM | 17M9G7D | |
| 27 | 1720.0 - 1745.0 | 0.1932 | 0.017 PM | 17M9W7D | |
| 22H | 829.0 - 844.0 | 0.1045 | 0.051 PM | 8M95G7D | |
| 22H | 829.0 - 844.0 | 0.1026 | 0.051 PM | 8M95W7D | |
| 27 | 2510.0 - 2560.0 | 0.1734 | 0.014 PM | 17M9G7D | |
| 27 | 2510.0 - 2560.0 | 0.171 | 0.014 PM | 17M9W7D | |
| 27 | 704.0 - 711.0 | 0.1023 | 0.049 PM | 8M94G7D | |
| 27 | 704.0 - 711.0 | 0.1009 | 0.049 PM | 8M94W7D | |
| 27 | 782.0 - 782.0 | 0.0887 | 0.047 PM | 8M94G7D | |
| 27 | 782.0 - 782.0 | 0.0863 | 0.047 PM | 8M94W7D | |
| 27 | 793.0 - 793.0 | 0.0975 | 0.045 PM | 8M94G7D | |
| 27 | 793.0 - 793.0 | 0.0957 | 0.045 PM | 8M92W7D | |
| 27 | 709.0 - 711.0 | 0.103 | 0.049 PM | 8M93G7D | |
| 27 | 709.0 - 711.0 | 0.1016 | 0.049 PM | 8M94W7D | |
| 24E | 1860.0 - 1905.0 | 0.1923 | 0.017 PM | 18M0G7D | |
| 24E | 1860.0 - 1905.0 | 0.1875 | 0.017 PM | 18M0W7D | |
| 22H | 831.5 - 841.5 | 0.1107 | 0.021 PM | 13M5G7D | |
| 22H | 831.5 - 841.5 | 0.1099 | 0.021 PM | 13M5W7D | |
| 90 | 819.0 - 819.0 | 0.0968 | 0.013 PM | 8M92G7D | |
| 90 | 819.0 - 819.0 | 0.0953 | 0.013 PM | 8M91W7D | |
| 27 | 2565.0 - 2645.0 | 0.173 | 0.019 PM | 17M9G7D | |
| 27 | 2565.0 - 2645.0 | 0.1706 | 0.019 PM | 17M9W7D | |
| 27 | 1720.0 - 1770.0 | 0.1866 | 0.021 PM | 17M9G7D | |
| 27 | 1720.0 - 1770.0 | 0.1824 | 0.021 PM | 17M9W7D | |
| 27 | 673.0 - 688.0 | 0.1052 | 0.045 PM | 18M0G7D | |
| 27 | 673.0 - 688.0 | 0.1026 | 0.045 PM | 18M0W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR head, body-worn, hotspot and simultaneous transmission use conditions is 0.35W/kg, 1.20W/kg, 1.20W/kg and 1.36W/kg respectively. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 06/28/2022 Application Dated: 06/28/2022 |
| BARTEC |
| Max-Eyth-Strasse 16 |
| Bad Mergentheim, 97980 Germany |
| Attention: Benedikt Eckert |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TBU-X8KPTPP |
| Name of Grantee: | BARTEC |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Pixavi Thermal/Pixavi Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0206 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.0211 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.0246 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.0034 |
| Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR head, body-worn, hotspot and simultaneous transmission use conditions is 0.63W/kg, 0.16W/kg, 0.16W/kg and 1.36W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application 7ZSy5Dgu5LqkZNzb6rqy7g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
BARTEC Max-Eyth-Strasse 16 Bad Mergentheim, 97980 Germany |
Date of Grant: 06/28/2022 Application Dated: 06/28/2022 |
| Attention: Benedikt Eckert |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TBU-X8KPTPP |
| Name of Grantee: | BARTEC |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Pixavi Thermal/Pixavi Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0206 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.0211 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.0246 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.0034 |
| Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR head, body-worn, hotspot and simultaneous transmission use conditions is 0.63W/kg, 0.16W/kg, 0.16W/kg and 1.36W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 05/29/2022 Application Dated: 05/29/2022 |
| BARTEC |
| Max-Eyth-Strasse 16 |
| Bad Mergentheim, 97980 Germany |
| Attention: Benedikt Eckert |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TBU-X8KPTPP |
| Name of Grantee: | BARTEC |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Pixavi Thermal/Pixavi Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0206 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.0211 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.0246 |
| Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR head, body-worn, hotspot and simultaneous transmission use conditions is 0.63W/kg, 0.16W/kg, 0.16W/kg and 1.36W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application 4KEUPx/1ijHLPhbZdG7PwQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
BARTEC Max-Eyth-Strasse 16 Bad Mergentheim, 97980 Germany |
Date of Grant: 05/29/2022 Application Dated: 05/29/2022 |
| Attention: Benedikt Eckert |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TBU-X8KPTPP |
| Name of Grantee: | BARTEC |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Pixavi Thermal/Pixavi Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0206 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.0211 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.0246 |
| Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR head, body-worn, hotspot and simultaneous transmission use conditions is 0.63W/kg, 0.16W/kg, 0.16W/kg and 1.36W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: |