Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2503.5-2682.5 MHzOriginal Equipment2019-09-30
2412-2472 MHzOriginal Equipment2019-09-30

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2020-03-27PDF 459 KB
Internal PhotosInternal Photos2020-03-27PDF 2.5 MB
External PhotosExternal Photos2020-03-27PDF 1.9 MB
label&locationID Label/Location Info2019-09-30PDF 127.5 KB
Test Setup Photos_PCBTest Setup Photos2020-03-27PDF 168.1 KB
Test Setup photo---DTSTest Setup Photos2020-03-27PDF 1.3 MB
Test Setup photo---SARTest Setup Photos2020-03-27PDF 278.5 KB
SZ19080292S01_GreenPacket_MX-725_FCC SAR Test ReportRF Exposure Info2019-09-30PDF 1.3 MB
SZ19080292W01_Green Packet_MX-725_wifi2.4G fccTest Report2019-09-30PDF 3.2 MB
SZ19080292W02_GreenPacket_MX-725_LTE_FCC_1Test Report2019-09-30PDF 5.4 MB
SZ19080292W02_GreenPacket_MX-725_LTE_FCC_2Test Report2019-09-30PDF 5.4 MB
Confidentiality_Request_Letter_long and shortCover Letter(s)2019-09-30PDF 106.5 KB
FCC Authorization LetterCover Letter(s)2019-09-30PDF 80.1 KB
SDoC_letterCover Letter(s)2019-09-30PDF 115 KB
Annex A General InformationRF Exposure Info2019-09-30PDF 44 KB
Annex C Plots of System Performance CheckRF Exposure Info2019-09-30PDF 241.5 KB
Annex D Plots of Maximum SAR Test ResultsRF Exposure Info2019-09-30PDF 233.4 KB
Annex E1 DASY Calibration Certificate_SN3823RF Exposure Info2019-09-30PDF 4.6 MB
Annex E2 DASY Calibration Certificate_DAE4-SN480RF Exposure Info2019-09-30PDF 2.4 MB
Annex E3 DASY Calibration Certificate_D2450V2RF Exposure Info2019-09-30PDF 2.9 MB
Annex E4 DASY Calibration Certificate_D2600V2RF Exposure Info2019-09-30PDF 3.9 MB
Block Diagram Metadata onlyBlock DiagramPDF 119.7 KB
SCH Metadata onlySchematicsPDF 304.1 KB
Operational Description Metadata onlyOperational DescriptionPDF 236.9 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 121.9 KB
Maximum power Tune-up tolerance Metadata onlyParts List/Tune Up InfoPDF 120.4 KB

Application Information

Application IDlbNQ2hJTcEPwYGcANZcRaA==
Final Action Date2019-09-30
Application PurposeOriginal Equipment
Applicant FRN0018658757
ModelMX725-GP
Frequency Range2503.5-2682.5 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionMIFI (LTE/ WIFI)
Responsible PartyFrank Hsu, VP, frankhsu@greenpacket.com , +886 2 2627 1355
Test FirmMr. Su Feng, Shenzhen Morlab Communications Technology Co. Ltd., Zx.sun@morlab.cn , +86 755 36698566
TCB Emailbentje.holger@phoenix-testlab.de
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date03/27/2020
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is maximum EIRP/ERP. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory, hotspot and simultaneous transmission use conditions are 0.69 W/kg, 1.54 W/kg and 1.54 W/kg, respectively.

Applications

Application IDDatePurpose
lbNQ2hJTcEPwYGcANZcRaA==2019-09-30Original Equipment
ThkFJxOWKNXgTdzbhNQ4vA==2019-09-30Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
2412-2472 MHz0.237000015CCC, MO
2503.5-2682.5 MHz0.2180.029ppm13M5G7D27
2506-2680 MHz0.2070.029ppm17M9G7D27
2506-2680 MHz0.1620.029ppm17M9W7D27

Grants

TCB Grant - Application ThkFJxOWKNXgTdzbhNQ4vA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 09/30/2019

Application Dated: 09/28/2019
Green Packet Berhad, Taiwan
2F, NO.23, LANE 583 RUEIGUANG RD,
NEIHU DISTRICT
Taipei City, 11492
Taiwan
 
Attention: Frank Hsu , VP

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  W9V-MX725-GP
Name of Grantee:  Green Packet Berhad, Taiwan
Equipment Class: Digital Transmission System
Notes: MIFI (LTE/ WIFI)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2472.0 0.237  

Output power is maximum peak conducted. This device supports 20/40 MHz channel bandwidth. This device supports MIMO 2T2R. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory, hotspot and simultaneous transmission use conditions are 0.69 W/kg, 1.54 W/kg and 1.54 W/kg, respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application ThkFJxOWKNXgTdzbhNQ4vA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Green Packet Berhad, Taiwan
2F, NO.23, LANE 583 RUEIGUANG RD, NEIHU DISTRICT
Taipei City, 11492
Taiwan
  Date of Grant: 09/30/2019

Application Dated: 09/28/2019
 
Attention: Frank Hsu , VP

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  W9V-MX725-GP
Name of Grantee:  Green Packet Berhad, Taiwan
Equipment Class: Digital Transmission System
Notes: MIFI (LTE/ WIFI)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2472.0 0.237  

Output power is maximum peak conducted. This device supports 20/40 MHz channel bandwidth. This device supports MIMO 2T2R. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory, hotspot and simultaneous transmission use conditions are 0.69 W/kg, 1.54 W/kg and 1.54 W/kg, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application lbNQ2hJTcEPwYGcANZcRaA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 09/30/2019

Application Dated: 09/28/2019
Green Packet Berhad, Taiwan
2F, NO.23, LANE 583 RUEIGUANG RD,
NEIHU DISTRICT
Taipei City, 11492
Taiwan
 
Attention: Frank Hsu , VP

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  W9V-MX725-GP
Name of Grantee:  Green Packet Berhad, Taiwan
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: MIFI (LTE/ WIFI)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 2506.0  -  2680.0 0.207 0.029  PM 17M9G7D
27 2506.0  -  2680.0 0.162 0.029  PM 17M9W7D
27 2503.5  -  2682.5 0.218 0.029  PM 13M5G7D

Output power is maximum EIRP/ERP. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory, hotspot and simultaneous transmission use conditions are 0.69 W/kg, 1.54 W/kg and 1.54 W/kg, respectively.

EAS Grant - Application lbNQ2hJTcEPwYGcANZcRaA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Green Packet Berhad, Taiwan
2F, NO.23, LANE 583 RUEIGUANG RD, NEIHU DISTRICT
Taipei City, 11492
Taiwan
  Date of Grant: 09/30/2019

Application Dated: 09/28/2019
 
Attention: Frank Hsu , VP

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  W9V-MX725-GP
Name of Grantee:  Green Packet Berhad, Taiwan
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: MIFI (LTE/ WIFI)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 2506.0  -  2680.0 0.207 0.029  PM 17M9G7D
27 2506.0  -  2680.0 0.162 0.029  PM 17M9W7D
27 2503.5  -  2682.5 0.218 0.029  PM 13M5G7D

Output power is maximum EIRP/ERP. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory, hotspot and simultaneous transmission use conditions are 0.69 W/kg, 1.54 W/kg and 1.54 W/kg, respectively.