FCC ID ZBW-MPHMB004

ID Screen 60

by IDEMIA Identity & Security France

Grantee Code: ZBW   Product Code: MPHMB004
Latest application date: 2022-04-08

FCC ID Device Details

FCC IDZBW-MPHMB004
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeZBW
Product CodeMPHMB004
Applicant BusinessIDEMIA Identity & Security France 🇫🇷
Related Domains idemia.com
Equipment ClassID Screen 60
Test FirmShenzhen Academy of Information and Communications

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2022-04-08
5180-5240 MHzOriginal Equipment2022-04-08
2572.5-2617.5 MHzOriginal Equipment2022-04-08
2402-2480 MHzOriginal Equipment2022-04-08
13.56 MHzOriginal Equipment2022-04-08

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2022-09-08PDF 2.6 MB
User manualUsers Manual2022-09-08PDF 2.6 MB
Users ManualUsers Manual2022-09-08PDF 2.6 MB
Internal PhotosInternal Photos2022-09-08PDF 427.1 KB
External PhotosExternal Photos2022-09-08PDF 705.3 KB
ID Label/Location InfoID Label/Location Info2022-04-08PDF 229.7 KB
Test Setup Photos_JBPTest Setup Photos2022-09-08PDF 1.5 MB
Test Setup Photos_SARTest Setup Photos2022-09-08PDF 898.8 KB
Test Report_BLETest Report2022-04-08PDF 1.1 MB
Test Report_DSSTest Report2022-04-08PDF 2.8 MB
Test Report_DXXTest Report2022-04-08PDF 428.5 KB
Test Report_GSMTest Report2022-04-08PDF 2.2 MB
Test Report_JBPTest Report2022-04-08PDF 3.1 MB
Test Report_LTETest Report2022-04-08PDF 4.1 MB
Test Report_NIITest Report2022-04-08PDF 4.5 MB
Test Report_SAR-1RF Exposure Info2022-04-08PDF 5.8 MB
Test Report_SAR-2RF Exposure Info2022-04-08PDF 4.9 MB
Test Report_UMTSTest Report2022-04-08PDF 1.8 MB
Test Report_WLANTest Report2022-04-08PDF 3.3 MB
Declaration of authorizationCover Letter(s)2022-04-08PDF 145.4 KB
DoC Metadata onlyCover Letter(s)2022-04-08PDF 309.8 KB
Request for LT or STC confidentialityCover Letter(s)2022-04-08PDF 204.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 109.2 KB
Schematics Metadata onlySchematicsPDF 4.6 MB
NII Software Security Info Metadata onlyOperational DescriptionPDF 432.2 KB
Operational Description Metadata onlyOperational DescriptionPDF 729 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 512 KB
Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 1,018.1 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 1,018.1 KB
Tune-up Procedure Metadata onlyParts List/Tune Up InfoPDF 1,018.1 KB

Application Information

Application IDgiuNBzwrr/qgRu1i79IX3A==
Final Action Date2022-04-08
Application PurposeOriginal Equipment
Applicant FRN0020652764
ModelMPHMB004
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionID Screen 60
Responsible PartySUEUR Christophe, Electronics Design Office Manager, christophe.sueur@idemia.com , +33130201434
Technical ContactChristophe SUEUR, IDEMIA Identity and Security France, christophe.sueur@idemia.com , 33 1 30 20 13 34
Non-Technical ContactChristophe SUEUR, IDEMIA Identity and Security France, christophe.sueur@idemia.com , 33 1 30 20 13 34
Test FirmXiao Li, Shenzhen Academy of Information and Communications, liuliping@caict.ac.cn , 86 755 33322000
TCB Emailcertification@telefication.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date09/08/2022
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is conducted. SAR compliance for body worn operating conditions is limited to the specific configuration tested for this filing. Body worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the user's body, which includes use as hotspot. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This device has 20/40 MHz bandwidth modes. The highest reported SAR values for body, and simultaneous transmission use conditions are 0.35 W/kg, and 1.51 W/kg, respectively.

Applications

Application IDDatePurpose
giuNBzwrr/qgRu1i79IX3A==2022-04-08Original Equipment
J3WQ7toHx7s0lcGhnE43PA==2022-04-08Original Equipment
98zAV5wuyiiAKi5MJpAzAQ==2022-04-08Original Equipment
5XlKg+VsQRv90DVPJsaO2w==2022-04-08Original Equipment
4XEZ31CKF8uxqvcA3DrI5Q==2022-04-08Original Equipment
2TtN/hv6hEZI1KEawUefSg==2022-04-08Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
15BCC
13.56 MHz15CCC
824.7-848.3 MHz0.0750.01ppm8M99G7D22H
824.7-848.3 MHz0.080.01ppm8M94W7D22H
826.4-846.6 MHz0.0520.01ppm4M50F9W22H
1710.7-1754.3 MHz0.1620.01ppm13M5G7D27
1710.7-1754.3 MHz0.1580.01ppm17M9G7D27
1710.7-1754.3 MHz0.1770.01ppm13M5W7D27
1710.7-1754.3 MHz0.1740.01ppm18M0W7D27
1850.2-1909.8 MHz1.4490.01ppm300KGXW24E
1850.2-1909.8 MHz0.4430.01ppm300KG7W24E
1850.7-1909.3 MHz0.1470.01ppm18M0W7D22H
1850.7-1909.3 MHz0.1640.01ppm1M10G7D22H
1850.7-1909.3 MHz0.1330.01ppm18M0G7D22H
1850.7-1909.3 MHz0.1820.01ppm1M09W7D22H
1852.4-1907.6 MHz0.1820.01ppm4M50F9W24E
2402-2480 MHz0.007700015CCC
2402-2480 MHz0.002215CCC
2412-2462 MHz0.05915CCC
2498.5-2687.5 MHz0.1270.01ppm4M50G7D27
2498.5-2687.5 MHz0.1180.01ppm18M0G7D27
2498.5-2687.5 MHz0.1280.01ppm4M50W7D27
2498.5-2687.5 MHz0.1270.01ppm18M0W7D27
2502.5-2567.5 MHz0.160.01ppm13M5G7D27
2502.5-2567.5 MHz0.140.01ppm18M0G7D27
2502.5-2567.5 MHz0.1710.01ppm18M0W7D27
2572.5-2617.5 MHz0.1690.01ppm18M0G7D27
2572.5-2617.5 MHz0.1720.01ppm18M0W7D27
5180-5240 MHz0.03715ECC
5260-5320 MHz0.03615ECC, ND
5500-5700 MHz0.03415ECC, ND
5745-5825 MHz0.02115ECC

Grants

TCB Grant - Application J3WQ7toHx7s0lcGhnE43PA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 04/08/2022

Application Dated: 03/29/2022
IDEMIA Identity & Security France
2, place Samuel de Champlain
Courbevoie, 92400
France
 
Attention: SUEUR Christophe , Electronics Design Office Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZBW-MPHMB004
Name of Grantee:  IDEMIA Identity & Security France
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: ID Screen 60
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.037  
CC ND 15E 5260.0  -  5320.0 0.036  
CC ND 15E 5500.0  -  5700.0 0.034  
CC 15E 5745.0  -  5825.0 0.021  

Power Output is conducted. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290 MHz, 5530 MHz, 5610 MHz and 5775 MHz.

The highest reported SAR values for body, and simultaneous transmission use conditions are 0.49 W/kg, and 1.51 W/kg, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application J3WQ7toHx7s0lcGhnE43PA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

IDEMIA Identity & Security France
2, place Samuel de Champlain
Courbevoie, 92400
France
  Date of Grant: 04/08/2022

Application Dated: 03/29/2022
 
Attention: SUEUR Christophe , Electronics Design Office Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZBW-MPHMB004
Name of Grantee:  IDEMIA Identity & Security France
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: ID Screen 60
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.037  
CC ND 15E 5260.0  -  5320.0 0.036  
CC ND 15E 5500.0  -  5700.0 0.034  
CC 15E 5745.0  -  5825.0 0.021  

Power Output is conducted. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This device has 20/40/80 MHz bandwidth modes. The 80 MHz mode is limited to channel at 5210MHz, 5290 MHz, 5530 MHz, 5610 MHz and 5775 MHz.

The highest reported SAR values for body, and simultaneous transmission use conditions are 0.49 W/kg, and 1.51 W/kg, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application giuNBzwrr/qgRu1i79IX3A==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 04/08/2022

Application Dated: 03/29/2022
IDEMIA Identity & Security France
2, place Samuel de Champlain
Courbevoie, 92400
France
 
Attention: SUEUR Christophe , Electronics Design Office Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZBW-MPHMB004
Name of Grantee:  IDEMIA Identity & Security France
Equipment Class: Digital Transmission System
Notes: ID Screen 60
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0022  
CC 15C 2412.0  -  2462.0 0.059  

Output power is conducted. SAR compliance for body worn operating conditions is limited to the specific configuration tested for this filing. Body worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the user's body, which includes use as hotspot. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This device has 20/40 MHz bandwidth modes. The highest reported SAR values for body, and simultaneous transmission use conditions are 0.35 W/kg, and 1.51 W/kg, respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application giuNBzwrr/qgRu1i79IX3A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

IDEMIA Identity & Security France
2, place Samuel de Champlain
Courbevoie, 92400
France
  Date of Grant: 04/08/2022

Application Dated: 03/29/2022
 
Attention: SUEUR Christophe , Electronics Design Office Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZBW-MPHMB004
Name of Grantee:  IDEMIA Identity & Security France
Equipment Class: Digital Transmission System
Notes: ID Screen 60
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0022  
CC 15C 2412.0  -  2462.0 0.059  

Output power is conducted. SAR compliance for body worn operating conditions is limited to the specific configuration tested for this filing. Body worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the user's body, which includes use as hotspot. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. This device has 20/40 MHz bandwidth modes. The highest reported SAR values for body, and simultaneous transmission use conditions are 0.35 W/kg, and 1.51 W/kg, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 98zAV5wuyiiAKi5MJpAzAQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 04/08/2022

Application Dated: 03/29/2022
IDEMIA Identity & Security France
2, place Samuel de Champlain
Courbevoie, 92400
France
 
Attention: SUEUR Christophe , Electronics Design Office Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZBW-MPHMB004
Name of Grantee:  IDEMIA Identity & Security France
Equipment Class: PCS Licensed Transmitter held to ear
Notes: ID Screen 60
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.689 0.01  PM 300KGXW
22H 824.2  -  848.8 0.224 0.01  PM 300KG7W
24E 1850.2  -  1909.8 1.449 0.01  PM 300KGXW
24E 1850.2  -  1909.8 0.443 0.01  PM 300KG7W
24E 1852.4  -  1907.6 0.182 0.01  PM 4M50F9W
22H 826.4  -  846.6 0.052 0.01  PM 4M50F9W
22H 1850.7  -  1909.3 0.164 0.01  PM 1M10G7D
22H 1850.7  -  1909.3 0.133 0.01  PM 18M0G7D
22H 1850.7  -  1909.3 0.182 0.01  PM 1M09W7D
22H 1850.7  -  1909.3 0.147 0.01  PM 18M0W7D
27 1710.7  -  1754.3 0.162 0.01  PM 13M5G7D
27 1710.7  -  1754.3 0.158 0.01  PM 17M9G7D
27 1710.7  -  1754.3 0.177 0.01  PM 13M5W7D
27 1710.7  -  1754.3 0.174 0.01  PM 18M0W7D
22H 824.7  -  848.3 0.075 0.01  PM 8M99G7D
22H 824.7  -  848.3 0.08 0.01  PM 8M94W7D
27 2502.5  -  2567.5 0.16 0.01  PM 13M5G7D
27 2502.5  -  2567.5 0.14 0.01  PM 18M0G7D
27 2502.5  -  2567.5 0.171 0.01  PM 18M0W7D
27 2572.5  -  2617.5 0.169 0.01  PM 18M0G7D
27 2572.5  -  2617.5 0.172 0.01  PM 18M0W7D
27 2498.5  -  2687.5 0.127 0.01  PM 4M50G7D
27 2498.5  -  2687.5 0.118 0.01  PM 18M0G7D
27 2498.5  -  2687.5 0.128 0.01  PM 4M50W7D
27 2498.5  -  2687.5 0.127 0.01  PM 18M0W7D

Power Output is ERP for part 22 and EIRP for Part 24 and 27. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body, which includes use as hotspot. End users must be informed of the body worn requirements for satisfying RF Exposure compliance.

The highest reported SAR values for body, and simultaneous transmission use conditions are 1.05 W/kg, and 1.51 W/kg, respectively.

This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations.


EAS Grant - Application 98zAV5wuyiiAKi5MJpAzAQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

IDEMIA Identity & Security France
2, place Samuel de Champlain
Courbevoie, 92400
France
  Date of Grant: 04/08/2022

Application Dated: 03/29/2022
 
Attention: SUEUR Christophe , Electronics Design Office Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZBW-MPHMB004
Name of Grantee:  IDEMIA Identity & Security France
Equipment Class: PCS Licensed Transmitter held to ear
Notes: ID Screen 60
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.689 0.01  PM 300KGXW
22H 824.2  -  848.8 0.224 0.01  PM 300KG7W
24E 1850.2  -  1909.8 1.449 0.01  PM 300KGXW
24E 1850.2  -  1909.8 0.443 0.01  PM 300KG7W
24E 1852.4  -  1907.6 0.182 0.01  PM 4M50F9W
22H 826.4  -  846.6 0.052 0.01  PM 4M50F9W
22H 1850.7  -  1909.3 0.164 0.01  PM 1M10G7D
22H 1850.7  -  1909.3 0.133 0.01  PM 18M0G7D
22H 1850.7  -  1909.3 0.182 0.01  PM 1M09W7D
22H 1850.7  -  1909.3 0.147 0.01  PM 18M0W7D
27 1710.7  -  1754.3 0.162 0.01  PM 13M5G7D
27 1710.7  -  1754.3 0.158 0.01  PM 17M9G7D
27 1710.7  -  1754.3 0.177 0.01  PM 13M5W7D
27 1710.7  -  1754.3 0.174 0.01  PM 18M0W7D
22H 824.7  -  848.3 0.075 0.01  PM 8M99G7D
22H 824.7  -  848.3 0.08 0.01  PM 8M94W7D
27 2502.5  -  2567.5 0.16 0.01  PM 13M5G7D
27 2502.5  -  2567.5 0.14 0.01  PM 18M0G7D
27 2502.5  -  2567.5 0.171 0.01  PM 18M0W7D
27 2572.5  -  2617.5 0.169 0.01  PM 18M0G7D
27 2572.5  -  2617.5 0.172 0.01  PM 18M0W7D
27 2498.5  -  2687.5 0.127 0.01  PM 4M50G7D
27 2498.5  -  2687.5 0.118 0.01  PM 18M0G7D
27 2498.5  -  2687.5 0.128 0.01  PM 4M50W7D
27 2498.5  -  2687.5 0.127 0.01  PM 18M0W7D

Power Output is ERP for part 22 and EIRP for Part 24 and 27. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body, which includes use as hotspot. End users must be informed of the body worn requirements for satisfying RF Exposure compliance.

The highest reported SAR values for body, and simultaneous transmission use conditions are 1.05 W/kg, and 1.51 W/kg, respectively.

This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations.



TCB Grant - Application 5XlKg+VsQRv90DVPJsaO2w==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 04/08/2022

Application Dated: 03/29/2022
IDEMIA Identity & Security France
2, place Samuel de Champlain
Courbevoie, 92400
France
 
Attention: SUEUR Christophe , Electronics Design Office Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZBW-MPHMB004
Name of Grantee:  IDEMIA Identity & Security France
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: ID Screen 60
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0077  

Power Output is conducted. End-users must be informed of transmitter operating conditions for satisfying RF exposure compliance. The highest reported SAR value for simultaneous transmission use condition is 1.42 W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 5XlKg+VsQRv90DVPJsaO2w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

IDEMIA Identity & Security France
2, place Samuel de Champlain
Courbevoie, 92400
France
  Date of Grant: 04/08/2022

Application Dated: 03/29/2022
 
Attention: SUEUR Christophe , Electronics Design Office Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZBW-MPHMB004
Name of Grantee:  IDEMIA Identity & Security France
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: ID Screen 60
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0077  

Power Output is conducted. End-users must be informed of transmitter operating conditions for satisfying RF exposure compliance. The highest reported SAR value for simultaneous transmission use condition is 1.42 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 4XEZ31CKF8uxqvcA3DrI5Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 04/08/2022

Application Dated: 03/31/2022
IDEMIA Identity & Security France
2, place Samuel de Champlain
Courbevoie, 92400
France
 
Attention: SUEUR Christophe , Electronics Design Office Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZBW-MPHMB004
Name of Grantee:  IDEMIA Identity & Security France
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: ID Screen 60
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 4XEZ31CKF8uxqvcA3DrI5Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

IDEMIA Identity & Security France
2, place Samuel de Champlain
Courbevoie, 92400
France
  Date of Grant: 04/08/2022

Application Dated: 03/31/2022
 
Attention: SUEUR Christophe , Electronics Design Office Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZBW-MPHMB004
Name of Grantee:  IDEMIA Identity & Security France
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: ID Screen 60
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 2TtN/hv6hEZI1KEawUefSg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 04/08/2022

Application Dated: 03/29/2022
IDEMIA Identity & Security France
2, place Samuel de Champlain
Courbevoie, 92400
France
 
Attention: SUEUR Christophe , Electronics Design Office Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZBW-MPHMB004
Name of Grantee:  IDEMIA Identity & Security France
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: ID Screen 60
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 2TtN/hv6hEZI1KEawUefSg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

IDEMIA Identity & Security France
2, place Samuel de Champlain
Courbevoie, 92400
France
  Date of Grant: 04/08/2022

Application Dated: 03/29/2022
 
Attention: SUEUR Christophe , Electronics Design Office Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZBW-MPHMB004
Name of Grantee:  IDEMIA Identity & Security France
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: ID Screen 60
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: