EVID-100nonB — Giteki 007-AP0151

This MIC record lists EVID-100nonB with applicant Evident Inspection Technologies Japan Corporation under Giteki number 007-AP0151.

Catalog checked against MIC data dated 2026-10-20. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
007-AP0151
Applicant
Evident Inspection Technologies Japan Corporation
Model / equipment
EVID-100nonB
Certification date
2025-10-29
Certifying organization
UL Japan Co., Ltd.
Certification year
2025

Radio equipment and technical records

Radio record 1

Certification date
2025-10-29
Applicant
Evident Inspection Technologies Japan Corporation
Model / equipment
EVID-100nonB
Certifying organization
UL Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
G1D 2412~2472MHz(5MHz spacing13 channels) 0.006068W/MHz,0.005554W/MHz G1D,D1D 2412~2472MHz(5MHz spacing 13 channels) 0.003550W/MHz,0.004768W/MHz,0.004601W/MHz,0.003319W/MHz,0.006067W/MHz,0.005413W/MHz G1D,D1D 2422~2462MHz(5MHz spacing9 channels) 0.004212W/MHz,0.004150W/MHz,0.003230W/MHz,0.003420W/MHz F1D 2441MHz 0.000277~0.000817W/MHz G1D 2441MHz 0.000216~0.000650W/MHz F1D 2402~2480MHz(2000kHz spacing40 channels) 0.008075W,0.006470W
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2025-10-29",
    "elecWave": "G1D 2412~2472MHz(5MHz間隔13波) 0.006068W/MHz,0.005554W/MHz\\nG1D,D1D 2412~2472MHz(5MHz間隔13波) 0.003550W/MHz,0.004768W/MHz,0.004601W/MHz,0.003319W/MHz,0.006067W/MHz,0.005413W/MHz\\nG1D,D1D 2422~2462MHz(5MHz間隔9波) 0.004212W/MHz,0.004150W/MHz,0.003230W/MHz,0.003420W/MHz\\nF1D 2441MHz 0.000277~0.000817W/MHz\\nG1D 2441MHz 0.000216~0.000650W/MHz\\nF1D 2402~2480MHz(2000kHz間隔40波) 0.008075W,0.006470W",
    "fqMaintainFunc": "無",
    "name": "Evident Inspection Technologies Japan Corporation",
    "note": "",
    "number": "007-AP0151",
    "organName": "(株)UL Japan",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "EVID-100nonB"
}

Radio record 2

Certification date
2025-10-29
Applicant
Evident Inspection Technologies Japan Corporation
Model / equipment
EVID-100nonB
Certifying organization
UL Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
G1D,D1D 5.18~5.24GHz(20MHz spacing 4 channels) 0.003646W/MHz,0.005402W/MHz,0.005431W/MHz,0.004506W/MHz,0.004797W/MHz,0.004786W/MHz G1D,D1D 5.19GHz,5.23GHz 0.002675W/MHz,0.002678W/MHz,0.002360W/MHz,0.002364W/MHz G1D,D1D 5.21GHz 0.001330W/MHz,0.001331W/MHz,0.001183W/MHz,0.001187W/MHz G1D, D1D 5.26~5.32GHz(20MHz spacing 4 channels) 0.002369W/MHz, 0.002662W/MHz, 0.002690W/MHz G1D,D1D 5.27GHz,5.31GHz 0.001330W/MHz,0.001337W/MHz G1D,D1D 5.29GHz 0.000647W/MHz,0.000659W/MHz G1D,D1D 5.25GHz 0.000330W/MHz,0.000334W/MHz G1D, D1D 5.50~5.72GHz(20MHz spacing 12 channels) 0.003479W/MHz, 0.005992W/MHz, 0.005761W/MHz G1D,D1D 5.51~5.71GHz(40MHz spacing6 channels) 0.004867W/MHz,0.004717W/MHz G1D,D1D 5.53~5.69GHz(80MHz spacing3 channels) 0.002266W/MHz,0.002060W/MHz G1D,D1D 5.57GHz 0.001105W/MHz,0.001100W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2025-10-29",
    "elecWave": "G1D,D1D 5.18~5.24GHz(20MHz間隔4波) 0.003646W/MHz,0.005402W/MHz,0.005431W/MHz,0.004506W/MHz,0.004797W/MHz,0.004786W/MHz\\nG1D,D1D 5.19GHz,5.23GHz 0.002675W/MHz,0.002678W/MHz,0.002360W/MHz,0.002364W/MHz\\nG1D,D1D 5.21GHz 0.001330W/MHz,0.001331W/MHz,0.001183W/MHz,0.001187W/MHz\\nG1D,D1D 5.26~5.32GHz(20MHz間隔4波) 0.002369W/MHz,0.002662W/MHz,0.002690W/MHz\\nG1D,D1D 5.27GHz,5.31GHz 0.001330W/MHz,0.001337W/MHz\\nG1D,D1D 5.29GHz 0.000647W/MHz,0.000659W/MHz\\nG1D,D1D 5.25GHz 0.000330W/MHz,0.000334W/MHz\\nG1D,D1D 5.50~5.72GHz(20MHz間隔12波) 0.003479W/MHz,0.005992W/MHz,0.005761W/MHz\\nG1D,D1D 5.51~5.71GHz(40MHz間隔6波) 0.004867W/MHz,0.004717W/MHz\\nG1D,D1D 5.53~5.69GHz(80MHz間隔3波) 0.002266W/MHz,0.002060W/MHz\\nG1D,D1D 5.57GHz 0.001105W/MHz,0.001100W/MHz",
    "fqMaintainFunc": "無",
    "name": "Evident Inspection Technologies Japan Corporation",
    "note": "",
    "number": "007-AP0151",
    "organName": "(株)UL Japan",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "EVID-100nonB"
}