- FCC ID1
- Japan Giteki2
- 210-1389023
Smart Access Point [RA345, RA340] — Giteki 210-138902
This MIC record lists Smart Access Point [RA345, RA340] with applicant Relay2, Inc. under Giteki number 210-138902.
Catalog checked against MIC data dated 2026-10-20. English translations shown first; original Japanese fields are available on each certificate.
Certificate information
- Certificate number
- 210-138902
- Applicant
- Relay2, Inc.
- Model / equipment
- Smart Access Point [RA345, RA340]
- Certification date
- 2020-05-11
- Certifying organization
- MiCOM Labs
- Certification year
- 2020
Radio equipment and technical records
Radio record 1
- Certification date
- 2020-05-11
- Applicant
- Relay2, Inc.
- Model / equipment
- Smart Access Point [RA345, RA340]
- Certifying organization
- MiCOM Labs
- Certification type
- Construction design certification under mutual recognition (MRA)
- Radio equipment class
- Specific radio equipment specified in Article 2, Item 19
- Emission, frequency and power
- 12M9G1D 2412~2472MHz 2mW/MHz
16M6D1D 2412~2472MHz 1.2mW/MHz
17M7D1D 2412~2472MHz 3.5mW/MHz
35M9D1D 2422~2462MHz 0.5mW/MHz
- Body SAR
- ―
- Frequency maintenance function
- No
- Spurious emission rules
- New spurious emission rules
All original source fields
{
"attachmentFileCntForCd1": "2",
"attachmentFileCntForCd2": "7",
"attachmentFileKey": "210_N_1_200520N210_%E8%AA%8D%E8%A8%BC_22_*****_*****",
"attachmentFileName": "210-138902_01_002.pdf\\n210-138902_01_003.pdf\\n210-138902_02_004.pdf\\n210-138902_02_005.pdf\\n210-138902_02_006.pdf\\n210-138902_02_007.pdf\\n210-138902_02_008.pdf\\n210-138902_02_009.pdf\\n210-138902_02_010.pdf",
"bodySar": "―",
"date": "2020-05-11",
"elecWave": "12M9G1D 2412~2472MHz 2mW/MHz\\n16M6D1D 2412~2472MHz 1.2mW/MHz\\n17M7D1D 2412~2472MHz 3.5mW/MHz\\n35M9D1D 2422~2462MHz 0.5mW/MHz",
"fqMaintainFunc": "無",
"name": "Relay2, Inc.",
"note": "",
"number": "210-138902",
"organName": "MiCOM Labs",
"radioEquipmentCode": "第2条第19号に規定する特定無線設備",
"spuriousRules": "新スプリアス規定",
"techCode": "相互承認(MRA)による工事設計認証",
"typeName": "Smart Access Point [RA345, RA340]"
}
Radio record 2
- Certification date
- 2020-05-11
- Applicant
- Relay2, Inc.
- Model / equipment
- Smart Access Point [RA345, RA340]
- Certifying organization
- MiCOM Labs
- Certification type
- Construction design certification under mutual recognition (MRA)
- Radio equipment class
- Specific radio equipment specified in Article 2, Item 19, Subitem 3
- Emission, frequency and power
- 16M5D1D 5180~5240MHz 0.3mW/MHz
17M7D1D 5180~5240MHz 1.2mW/MHz
17M7D1D 5180~5240MHz 1.2mW/MHz
35M9D1D 5190~5230MHz 0.55mW/MHz
35M9D1D 5190~5230MHz 0.55mW/MHz
75M7D1D 5210~5210MHz 0.3mW/MHz
155MD1D 5250~5250MHz 0.1mW/MHz
16M5D1D 5260~5320MHz 0.3mW/MHz
17M7D1D 5260~5320MHz 1.2mW/MHz
17M7D1D 5260~5320MHz 1.2mW/MHz
35M9D1D 5270~5310MHz 0.55mW/MHz
35M9D1D 5270~5310MHz 0.55mW/MHz
75M7D1D 5290~5290MHz 0.3mW/MHz
- Body SAR
- ―
- Frequency maintenance function
- No
- Spurious emission rules
- New spurious emission rules
All original source fields
{
"attachmentFileCntForCd1": "",
"attachmentFileCntForCd2": "",
"attachmentFileKey": "",
"attachmentFileName": "",
"bodySar": "―",
"date": "2020-05-11",
"elecWave": "16M5D1D 5180~5240MHz 0.3mW/MHz\\n17M7D1D 5180~5240MHz 1.2mW/MHz\\n17M7D1D 5180~5240MHz 1.2mW/MHz\\n35M9D1D 5190~5230MHz 0.55mW/MHz\\n35M9D1D 5190~5230MHz 0.55mW/MHz\\n75M7D1D 5210~5210MHz 0.3mW/MHz\\n155MD1D 5250~5250MHz 0.1mW/MHz\\n16M5D1D 5260~5320MHz 0.3mW/MHz\\n17M7D1D 5260~5320MHz 1.2mW/MHz\\n17M7D1D 5260~5320MHz 1.2mW/MHz\\n35M9D1D 5270~5310MHz 0.55mW/MHz\\n35M9D1D 5270~5310MHz 0.55mW/MHz\\n75M7D1D 5290~5290MHz 0.3mW/MHz",
"fqMaintainFunc": "無",
"name": "Relay2, Inc.",
"note": "",
"number": "210-138902",
"organName": "MiCOM Labs",
"radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
"spuriousRules": "新スプリアス規定",
"techCode": "相互承認(MRA)による工事設計認証",
"typeName": "Smart Access Point [RA345, RA340]"
}
Radio record 3
- Certification date
- 2020-05-11
- Applicant
- Relay2, Inc.
- Model / equipment
- Smart Access Point [RA345, RA340]
- Certifying organization
- MiCOM Labs
- Certification type
- Construction design certification under mutual recognition (MRA)
- Radio equipment class
- Specific radio equipment specified in Article 2, Item 19, Subitem 3, Section 2
- Emission, frequency and power
- 16M6D1D 5500~5700MHz 0.3mW/MHz
17M7D1D 5500~5700MHz 1.2mW/MHz
17M7D1D 5500~5700MHz 1.2mW/MHz
36M0D1D 5510~5670MHz 0.55mW/MHz
36M0D1D 5510~5670MHz 0.55mW/MHz
75M8D1D 5530~5530MHz 0.3mW/MHz
155MD1D 5570~5570MHz 0.1mW/MHz
- Body SAR
- ―
- Frequency maintenance function
- No
- Spurious emission rules
- New spurious emission rules
All original source fields
{
"attachmentFileCntForCd1": "",
"attachmentFileCntForCd2": "",
"attachmentFileKey": "",
"attachmentFileName": "",
"bodySar": "―",
"date": "2020-05-11",
"elecWave": "16M6D1D 5500~5700MHz 0.3mW/MHz\\n17M7D1D 5500~5700MHz 1.2mW/MHz\\n17M7D1D 5500~5700MHz 1.2mW/MHz\\n36M0D1D 5510~5670MHz 0.55mW/MHz\\n36M0D1D 5510~5670MHz 0.55mW/MHz\\n75M8D1D 5530~5530MHz 0.3mW/MHz\\n155MD1D 5570~5570MHz 0.1mW/MHz",
"fqMaintainFunc": "無",
"name": "Relay2, Inc.",
"note": "",
"number": "210-138902",
"organName": "MiCOM Labs",
"radioEquipmentCode": "第2条第19号の3の2に規定する特定無線設備",
"spuriousRules": "新スプリアス規定",
"techCode": "相互承認(MRA)による工事設計認証",
"typeName": "Smart Access Point [RA345, RA340]"
}
Photos and test report documents