- FCC ID1
- Japan Giteki2
- 211-1409033
TDBAC22D — Giteki 211-140903
This MIC record lists TDBAC22D with applicant Ruckus Wireless, Inc. under Giteki number 211-140903.
Catalog checked against MIC data dated 2026-11-13. English translations shown first; original Japanese fields are available on each certificate.
Certificate information
- Certificate number
- 211-140903
- Applicant
- Ruckus Wireless, Inc.
- Model / equipment
- TDBAC22D
- Certification date
- 2015-01-30
- Certifying organization
- Bay Area Compliance Laboratories Corp
- Certification year
- 2015
Radio equipment and technical records
Radio record 1
- Certification date
- 2015-01-30
- Applicant
- Ruckus Wireless, Inc.
- Model / equipment
- TDBAC22D
- Certifying organization
- Bay Area Compliance Laboratories Corp
- Certification type
- Construction design certification under mutual recognition (MRA)
- Radio equipment class
- Specific radio equipment specified in Article 2, Item 19
- Emission, frequency and power
- G1D 2412-2472MHz(5MHz 13CH) 7.76mW\/MHz
G1D, D1D 2412-2472MHz(5MHz 13CH) 7.85mW\/MHz
G1D, D1D 2422-2462MHz(5MHz 9CH) 3.96mW\/MHz
- Body SAR
- ―
- Frequency maintenance function
- No
- Spurious emission rules
- New spurious emission rules
- Notes
- The change history is as follows.
Changed as follows on 2024/01/01
[Name or Title] Ruckus Wireless LLC
All original source fields
{
"attachmentFileCntForCd1": "",
"attachmentFileCntForCd2": "",
"attachmentFileKey": "",
"attachmentFileName": "",
"bodySar": "―",
"date": "2015-01-30",
"elecWave": "G1D 2412-2472MHz(5MHz 13CH) 7.76mW\\/MHz\\nG1D, D1D 2412-2472MHz(5MHz 13CH) 7.85mW\\/MHz\\nG1D, D1D 2422-2462MHz(5MHz 9CH) 3.96mW\\/MHz",
"fqMaintainFunc": "無",
"name": "Ruckus Wireless, Inc.",
"note": "変更履歴は次のとおり。\\n・2024年01月01日に下記のとおり変更\\n【氏名又は名称】Ruckus Wireless LLC",
"number": "211-140903",
"organName": "Bay Area Compliance Laboratories Corp",
"radioEquipmentCode": "第2条第19号に規定する特定無線設備",
"spuriousRules": "新スプリアス規定",
"techCode": "相互承認(MRA)による工事設計認証",
"typeName": "TDBAC22D"
}
Radio record 2
- Certification date
- 2015-01-30
- Applicant
- Ruckus Wireless, Inc.
- Model / equipment
- TDBAC22D
- Certifying organization
- Bay Area Compliance Laboratories Corp
- Certification type
- Construction design certification under mutual recognition (MRA)
- Radio equipment class
- Specific radio equipment specified in Article 2, Item 19, Subitem 3
- Emission, frequency and power
- G1D, D1D 5180-5240MHz(20MHz 4CH) 4.13mW\/MHz
G1D, D1D 5190-5230MHz(40MHz 2CH) 2.06mW\/MHz
G1D, D1D 5260-5320MHz(20MHz 4CH) 4.27mW\/MHz
G1D, D1D 5270-5310MHz(40MHz 2CH) 2.13mW\/MHz
G1D, D1D 5210-5290MHz(80MHz 2CH) 1.0mW\/MHz
- Body SAR
- ―
- Frequency maintenance function
- No
- Spurious emission rules
- New spurious emission rules
- Notes
- The change history is as follows.
Changed as follows on 2024/01/01
[Name or Title] Ruckus Wireless LLC
All original source fields
{
"attachmentFileCntForCd1": "",
"attachmentFileCntForCd2": "",
"attachmentFileKey": "",
"attachmentFileName": "",
"bodySar": "―",
"date": "2015-01-30",
"elecWave": "G1D, D1D 5180-5240MHz(20MHz 4CH) 4.13mW\\/MHz\\nG1D, D1D 5190-5230MHz(40MHz 2CH) 2.06mW\\/MHz\\nG1D, D1D 5260-5320MHz(20MHz 4CH) 4.27mW\\/MHz\\nG1D, D1D 5270-5310MHz(40MHz 2CH) 2.13mW\\/MHz\\nG1D, D1D 5210-5290MHz(80MHz 2CH) 1.0mW\\/MHz",
"fqMaintainFunc": "無",
"name": "Ruckus Wireless, Inc.",
"note": "変更履歴は次のとおり。\\n・2024年01月01日に下記のとおり変更\\n【氏名又は名称】Ruckus Wireless LLC",
"number": "211-140903",
"organName": "Bay Area Compliance Laboratories Corp",
"radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
"spuriousRules": "新スプリアス規定",
"techCode": "相互承認(MRA)による工事設計認証",
"typeName": "TDBAC22D"
}
Radio record 3
- Certification date
- 2015-01-30
- Applicant
- Ruckus Wireless, Inc.
- Model / equipment
- TDBAC22D
- Certifying organization
- Bay Area Compliance Laboratories Corp
- Certification type
- Construction design certification under mutual recognition (MRA)
- Radio equipment class
- Specific radio equipment specified in Article 2, Item 19, Subitem 3, Section 2
- Emission, frequency and power
- G1D, D1D 5500-5700MHz(20MHz 11CH) 8.93mW\/MHz
G1D, D1D 5510-5670MHz(40MHz 5CH) 4.40mW\/MHz
G1D, D1D 5530-5610MHz(80MHz 2CH) 0.55mW\/MHz
- Body SAR
- ―
- Frequency maintenance function
- No
- Spurious emission rules
- New spurious emission rules
- Notes
- The change history is as follows.
Changed as follows on 2024/01/01
[Name or Title] Ruckus Wireless LLC
All original source fields
{
"attachmentFileCntForCd1": "",
"attachmentFileCntForCd2": "",
"attachmentFileKey": "",
"attachmentFileName": "",
"bodySar": "―",
"date": "2015-01-30",
"elecWave": "G1D, D1D 5500-5700MHz(20MHz 11CH) 8.93mW\\/MHz\\nG1D, D1D 5510-5670MHz(40MHz 5CH) 4.40mW\\/MHz\\nG1D, D1D 5530-5610MHz(80MHz 2CH) 0.55mW\\/MHz",
"fqMaintainFunc": "無",
"name": "Ruckus Wireless, Inc.",
"note": "変更履歴は次のとおり。\\n・2024年01月01日に下記のとおり変更\\n【氏名又は名称】Ruckus Wireless LLC",
"number": "211-140903",
"organName": "Bay Area Compliance Laboratories Corp",
"radioEquipmentCode": "第2条第19号の3の2に規定する特定無線設備",
"spuriousRules": "新スプリアス規定",
"techCode": "相互承認(MRA)による工事設計認証",
"typeName": "TDBAC22D"
}
Photos and test report documents
No attachment documents are listed in this MIC record.
Source: Japan Ministry of Internal Affairs and Communications (MIC). Giteki search · Free search and verification API · Search FCCID.io