SMG973U Multi-band GSM/EDGE/CDMA/UMTS/LTE Phone with Bluetooth, WLAN, RFID and ANT+ RF Exposure Info 2 Samsung Electronics Co Ltd
Samsung Electronics Co Ltd Multi-band GSM/EDGE/CDMA/UMTS/LTE Phone with Bluetooth, WLAN, RFID and ANT+
PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1057 Communication System: UID 0, CW; Frequency: 5250 MHz; Duty Cycle: 1:1 Medium: 5GHz Head Medium parameters used (interpolated): f = 5250 MHz; σ = 4.593 S/m; εr = 35.307; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-26-2018; Ambient Temp: 20.5°C; Tissue Temp: 20.2°C Probe: EX3DV4 - SN7409; ConvF(5.2, 5.2, 5.2) @ 5250 MHz; Calibrated: 6/25/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1334; Calibrated: 6/18/2018 Phantom: SAM with CRP v5.0 (Right); Type: QD000P40CD; Serial: TP:1759 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5250 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 15.8 W/kg SAR(1 g) = 3.87 W/kg Deviation(1 g) = -2.27% 0 dB = 9.09 W/kg = 9.59 dBW/kg B15 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1057 Communication System: UID 0, CW; Frequency: 5600 MHz; Duty Cycle: 1:1 Medium: 5GHz Head Medium parameters used: f = 5600 MHz; σ = 4.957 S/m; εr = 34.816; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-26-2018; Ambient Temp: 20.5°C; Tissue Temp: 20.2°C Probe: EX3DV4 - SN7409; ConvF(4.77, 4.77, 4.77) @ 5600 MHz; Calibrated: 6/25/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1334; Calibrated: 6/18/2018 Phantom: SAM with CRP v5.0 (Right); Type: QD000P40CD; Serial: TP:1759 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5600 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 18.2 W/kg SAR(1 g) = 4.09 W/kg Deviation(1 g) = -2.73% 0 dB = 9.74 W/kg = 9.89 dBW/kg B16 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1057 Communication System: UID 0, CW; Frequency: 5750 MHz; Duty Cycle: 1:1 Medium: 5GHz Head Medium parameters used (interpolated): f = 5750 MHz; σ = 5.111 S/m; εr = 34.607; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-26-2018; Ambient Temp: 20.5°C; Tissue Temp: 20.2°C Probe: EX3DV4 - SN7409; ConvF(4.82, 4.82, 4.82) @ 5750 MHz; Calibrated: 6/25/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1334; Calibrated: 6/18/2018 Phantom: SAM with CRP v5.0 (Right); Type: QD000P40CD; Serial: TP:1759 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5750 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 18.0 W/kg SAR(1 g) = 3.79 W/kg Deviation(1 g) = -5.84% 0 dB = 9.34 W/kg = 9.70 dBW/kg B17 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 750 MHz; Type: D750V3; Serial: 1054 Communication System: UID 0, CW; Frequency: 750 MHz; Duty Cycle: 1:1 Medium: 750 Body; Medium parameters used (interpolated): f = 750 MHz; σ = 0.966 S/m; εr = 52.992; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-18-2018; Ambient Temp: 21.4°C; Tissue Temp: 20.4°C Probe: EX3DV4 - SN7406; ConvF(9.91, 9.91, 9.91) @ 750 MHz; Calibrated: 5/22/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn859; Calibrated: 5/22/2018 Phantom: Twin-SAM V5.0 Back Right; Type: QD 000 P40 CD; Serial: 1692 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 750 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x15x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 2.75 W/kg SAR(1 g) = 1.78 W/kg Deviation(1 g) = 3.37% 0 dB = 2.42 W/kg = 3.84 dBW/kg B18 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d047 Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1 Medium: 835 Body Medium parameters used: f = 835 MHz; σ = 0.957 S/m; εr = 53.795; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-14-2018; Ambient Temp: 23.5°C; Tissue Temp: 21.4°C Probe: EX3DV4 - SN7410; ConvF(9.63, 9.63, 9.63) @ 835 MHz; Calibrated: 7/20/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1322; Calibrated: 7/11/2018 Phantom: SAM Front; Type: SAM; Serial: 1686 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 835 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 3.14 W/kg SAR(1 g) = 2.08 W/kg Deviation(1 g) = 7.11% 0 dB = 2.78 W/kg = 4.44 dBW/kg B19 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d132 Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1 Medium: 835 Body; Medium parameters used: f = 835 MHz; σ = 0.957 S/m; εr = 53.433; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-25-2018; Ambient Temp: 20.1°C; Tissue Temp: 21.3°C Probe: EX3DV4 - SN7409; ConvF(9.63, 9.63, 9.63) @ 835 MHz; Calibrated: 6/25/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1334; Calibrated: 6/18/2018 Phantom: SAM with CRP v5.0 (Right); Type: QD000P40CD; Serial: TP:1759 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 835 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 3.14 W/kg SAR(1 g) = 2.04 W/kg Deviation(1 g) = 5.05% 0 dB = 2.76 W/kg = 4.41 dBW/kg B20 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d133 Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1 Medium: 835 Body Medium parameters used: f = 835 MHz; σ = 0.954 S/m; εr = 55.283; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-27-2018; Ambient Temp: 22.0°C; Tissue Temp: 20.3°C Probe: EX3DV4 - SN7308; ConvF(10.19, 10.19, 10.19) @ 835 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V8.0; Type: QD 000 P41 Ax; Serial: 1966 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 835 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 2.83 W/kg SAR(1 g) = 1.87 W/kg Deviation(1 g) = -4.10% 0 dB = 2.49 W/kg = 3.96 dBW/kg B21 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d047 Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1 Medium: 835 Body; Medium parameters used: f = 835 MHz; σ = 0.982 S/m; εr = 53.648; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-29-2018; Ambient Temp: 21.4°C; Tissue Temp: 19.9°C Probe: EX3DV4 - SN7406; ConvF(9.61, 9.61, 9.61) @ 835 MHz; Calibrated: 5/22/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn859; Calibrated: 5/22/2018 Phantom: Twin-SAM V4.0 Front Right; Type: QD 000 P40 CC; Serial: 1167 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 835 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 3.12 W/kg SAR(1 g) = 2.04 W/kg Deviation(1 g) = 5.05% 0 dB = 2.75 W/kg = 4.39 dBW/kg B22 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d047 Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1 Medium: 835 Body; Medium parameters used: f = 835 MHz; σ = 0.974 S/m; εr = 55; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 12-03-2018; Ambient Temp: 21.3°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7406; ConvF(9.61, 9.61, 9.61) @ 835 MHz; Calibrated: 5/22/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn859; Calibrated: 5/22/2018 Phantom: Twin-SAM V4.0 Front Right; Type: QD 000 P40 CC; Serial: 1167 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 835 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 3.06 W/kg SAR(1 g) = 2.01 W/kg Deviation(1 g) = 3.50% 0 dB = 2.69 W/kg = 4.30 dBW/kg B23 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1750 MHz; Type: D1750V2; Serial: 1148 Communication System: UID 0, CW; Frequency: 1750 MHz; Duty Cycle: 1:1 Medium: 1750 Body Medium parameters used: f = 1750 MHz; σ = 1.544 S/m; εr = 51.081; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-15-2018; Ambient Temp: 19.7°C; Tissue Temp: 19.6°C Probe: ES3DV3 - SN3347; ConvF(5.17, 5.17, 5.17) @ 1750 MHz; Calibrated: 3/27/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn665; Calibrated: 2/15/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1800 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1750 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 6.98 W/kg SAR(1 g) = 3.93 W/kg; SAR(10 g) = 2.07 W/kg Deviation(1 g) = 6.22%; Deviation(10 g) = 4.55% 0 dB = 4.93 W/kg = 6.93 dBW/kg B24 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1750 MHz; Type: D1750V2; Serial: 1148 Communication System: UID 0, CW; Frequency: 1750 MHz; Duty Cycle: 1:1 Medium: 1750 Body Medium parameters used: f = 1750 MHz; σ = 1.49 S/m; εr = 50.865; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-18-2018; Ambient Temp: 19.9°C; Tissue Temp: 21.0°C Probe: ES3DV3 - SN3347; ConvF(5.17, 5.17, 5.17) @ 1750 MHz; Calibrated: 3/27/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn665; Calibrated: 2/15/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1800 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1750 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 6.64 W/kg SAR(10 g) = 1.97 W/kg Deviation(10 g) = -0.51% 0 dB = 4.74 W/kg = 6.76 dBW/kg B25 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1750 MHz; Type: D1750V2; Serial: 1150 Communication System: UID 0, CW; Frequency: 1750 MHz; Duty Cycle: 1:1 Medium: 1750 Body Medium parameters used: f = 1750 MHz; σ = 1.513 S/m; εr = 50.84; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-21-2018; Ambient Temp: 19.7°C; Tissue Temp: 21.1°C Probe: ES3DV3 - SN3347; ConvF(5.17, 5.17, 5.17) @ 1750 MHz; Calibrated: 3/27/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn665; Calibrated: 2/15/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1800 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1750 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 6.73 W/kg SAR(1 g) = 3.8 W/kg Deviation(1 g) = 3.83% 0 dB = 4.76 W/kg = 6.78 dBW/kg B26 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1750 MHz; Type: D1750V2; Serial: 1148 Communication System: UID 0, CW; Frequency: 1750 MHz; Duty Cycle: 1:1 Medium: 1750 Body; Medium parameters used: f = 1750 MHz; σ = 1.542 S/m; εr = 51.118; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-04-2018; Ambient Temp: 22.6°C; Tissue Temp: 20.2°C Probe: EX3DV4 - SN7409; ConvF(7.91, 7.91, 7.91) @ 1750 MHz; Calibrated: 6/25/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1334; Calibrated: 6/18/2018 Phantom: SAM with CRP (Left); Type: SAM; Serial: 1715 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1750 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 7.23 W/kg SAR(1 g) = 3.92 W/kg Deviation(1 g) = 5.95% 0 dB = 5.99 W/kg = 7.77 dBW/kg B27 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body; Medium parameters used (interpolated): f = 1900 MHz; σ = 1.575 S/m; εr = 51.505; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-12-2018; Ambient Temp: 21.8°C; Tissue Temp: 21.0°C Probe: EX3DV4 - SN7409; ConvF(7.6, 7.6, 7.6) @ 1900 MHz; Calibrated: 6/25/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1334; Calibrated: 6/18/2018 Phantom: SAM with CRP (Left); Type: SAM; Serial: 1715 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 7.79 W/kg SAR(1 g) = 4.17 W/kg Deviation(1 g) = 5.30% 0 dB = 6.51 W/kg = 8.14 dBW/kg B28 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body Medium parameters used (interpolated): f = 1900 MHz; σ = 1.579 S/m; εr = 51.286; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-14-2018; Ambient Temp: 23.9°C; Tissue Temp: 21.3°C Probe: ES3DV3 - SN3213; ConvF(4.88, 4.88, 4.88) @ 1900 MHz; Calibrated: 2/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x10x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 7.46 W/kg SAR(1 g) = 4.23 W/kg Deviation(1 g) = 6.82% 0 dB = 5.36 W/kg = 7.29 dBW/kg B29 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body Medium parameters used (interpolated): f = 1900 MHz; σ = 1.545 S/m; εr = 51.477; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-19-2018; Ambient Temp: 24.4°C; Tissue Temp: 21.8°C Probe: ES3DV3 - SN3213; ConvF(4.88, 4.88, 4.88) @ 1900 MHz; Calibrated: 2/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x10x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 6.96 W/kg SAR(1 g) = 3.97 W/kg; SAR(10 g) = 2.06 W/kg Deviation(1 g) = 0.25%; Deviation(10 g) = -1.44% 0 dB = 5.04 W/kg = 7.02 dBW/kg B30 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body; Medium parameters used (interpolated): f = 1900 MHz; σ = 1.58 S/m; εr = 51.197; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-28-2018; Ambient Temp: 21.2°C; Tissue Temp: 20.8°C Probe: ES3DV3 - SN3213; ConvF(4.88, 4.88, 4.88) @ 1900 MHz; Calibrated: 2/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x10x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 6.92 W/kg SAR(1 g) = 3.89 W/kg Deviation(1 g) = -1.77% 0 dB = 4.94 W/kg = 6.94 dBW/kg B31 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d080 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body; Medium parameters used (interpolated): f = 1900 MHz; σ = 1.577 S/m; εr = 52.302; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-02-2018; Ambient Temp: 21.9°C; Tissue Temp: 21.8°C Probe: EX3DV4 - SN7409; ConvF(7.6, 7.6, 7.6) @ 1900 MHz; Calibrated: 6/25/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1334; Calibrated: 6/18/2018 Phantom: SAM with CRP v5.0 (Right); Type: QD000P40CD; Serial: TP:1759 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 7.87 W/kg SAR(1 g) = 4.19 W/kg; SAR(10 g) = 2.14 W/kg Deviation(1 g) = 6.89%; Deviation(10 g) = 3.88% 0 dB = 6.58 W/kg = 8.18 dBW/kg B32 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body Medium parameters used (interpolated): f = 1900 MHz; σ = 1.572 S/m; εr = 51.023; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-05-2018; Ambient Temp: 24.5°C; Tissue Temp: 23.3°C Probe: ES3DV3 - SN3332; ConvF(4.77, 4.77, 4.77) @ 1900 MHz; Calibrated: 8/22/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x10x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 7.40 W/kg SAR(1 g) = 4.15 W/kg Deviation(1 g) = 4.80% 0 dB = 5.18 W/kg = 7.14 dBW/kg B33 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2300 MHz; Type: D2300V2; Serial: 1073 Communication System: UID 0, CW; Frequency: 2300 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2300 MHz; σ = 1.871 S/m; εr = 51.484; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-14-2018; Ambient Temp: 21.9°C; Tissue Temp: 22.5°C Probe: ES3DV3 - SN3319; ConvF(4.63, 4.63, 4.63) @ 2300 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2300 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 9.54 W/kg SAR(1 g) = 4.85 W/kg; SAR(10 g) = 2.3 W/kg Deviation(1 g) = 1.68%; Deviation(10 g) = -0.86% 0 dB = 6.35 W/kg = 8.03 dBW/kg B34 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2300 MHz; Type: D2300V2; Serial: 1073 Communication System: UID 0, CW; Frequency: 2300 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2300 MHz; σ = 1.878 S/m; εr = 51.069; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-20-2018; Ambient Temp: 23.2°C; Tissue Temp: 23.5°C Probe: ES3DV3 - SN3319; ConvF(4.63, 4.63, 4.63) @ 2300 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2300 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 10.0 W/kg SAR(1 g) = 5.08 W/kg Deviation(1 g) = 6.50% 0 dB = 6.54 W/kg = 8.16 dBW/kg B35 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 719 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2450 MHz; σ = 2.033 S/m; εr = 52.107; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-12-2018; Ambient Temp: 22.7°C; Tissue Temp: 21.0°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2450 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 10.6 W/kg SAR(1 g) = 5.13 W/kg Deviation(1 g) = 2.40% 0 dB = 6.79 W/kg = 8.32 dBW/kg B36 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 719 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2450 MHz; σ = 2.045 S/m; εr = 51.016; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-14-2018; Ambient Temp: 21.9°C; Tissue Temp: 22.5°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2450 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 10.7 W/kg SAR(1 g) = 5.09 W/kg Deviation(1 g) = 1.60% 0 dB = 6.75 W/kg = 8.29 dBW/kg B37 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 797 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2450 MHz; σ = 2.03 S/m; εr = 51.031; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-17-2018; Ambient Temp: 24.9°C; Tissue Temp: 22.7°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2450 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 10.4 W/kg SAR(1 g) = 4.94 W/kg; SAR(10 g) = 2.25 W/kg Deviation(1 g) = -3.33%; Deviation(10 g) = -7.02% 0 dB = 6.48 W/kg = 8.12 dBW/kg B38 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 797 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2450 MHz; σ = 2.036 S/m; εr = 50.942; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-29-2018; Ambient Temp: 22.6°C; Tissue Temp: 22.9°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2450 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 11.0 W/kg SAR(1 g) = 5.26 W/kg Deviation(1 g) = 2.94% 0 dB = 6.98 W/kg = 8.44 dBW/kg B39 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 719 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2450 MHz; σ = 2.031 S/m; εr = 51.814; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-05-2018; Ambient Temp: 22.7°C; Tissue Temp: 21.3°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2450 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 10.8 W/kg SAR(1 g) = 5.23 W/kg Deviation(1 g) = 4.39% 0 dB = 6.88 W/kg = 8.38 dBW/kg B40 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 719 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Body; Medium parameters used: f = 2450 MHz; σ = 2.028 S/m; εr = 51.398; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-27-2018; Ambient Temp: 22.5°C; Tissue Temp: 21.9°C Probe: EX3DV4 - SN7406; ConvF(7.3, 7.3, 7.3) @ 2450 MHz; Calibrated: 5/22/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn859; Calibrated: 5/22/2018 Phantom: Twin-SAM V5.0 Back Right; Type: QD 000 P40 CD; Serial: 1692 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 11.1 W/kg SAR(1 g) = 5.34 W/kg Deviation(1 g) = 6.59% 0 dB = 8.93 W/kg = 9.51 dBW/kg B41 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 981 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2450 MHz; σ = 2.039 S/m; εr = 51.588; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 01-14-2019; Ambient Temp: 22.3°C; Tissue Temp: 21.6°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2450 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 10.5 W/kg SAR(10 g) = 2.27 W/kg Deviation(10 g) = -6.20% 0 dB = 6.59 W/kg = 8.19 dBW/kg B42 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2600 MHz; Type: D2600V2; Serial: 1071 Communication System: UID 0, CW; Frequency: 2600 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2600 MHz; σ = 2.208 S/m; εr = 50.554; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-17-2018; Ambient Temp: 24.9°C; Tissue Temp: 22.7°C Probe: ES3DV3 - SN3319; ConvF(4.33, 4.33, 4.33) @ 2600 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2600 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 11.2 W/kg SAR(1 g) = 5.08 W/kg; SAR(10 g) = 2.23 W/kg Deviation(1 g) = -6.27%; Deviation(10 g) = -8.98% 0 dB = 6.77 W/kg = 8.31 dBW/kg B43 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2600 MHz; Type: D2600V2; Serial: 1071 Communication System: UID 0, CW; Frequency: 2600 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2600 MHz; σ = 2.21 S/m; εr = 50.505; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-29-2018; Ambient Temp: 22.6°C; Tissue Temp: 22.9°C Probe: ES3DV3 - SN3319; ConvF(4.33, 4.33, 4.33) @ 2600 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2600 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 12.5 W/kg SAR(1 g) = 5.67 W/kg Deviation(1 g) = 4.61% 0 dB = 7.49 W/kg = 8.74 dBW/kg B44 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2600 MHz; Type: D2600V2; Serial: 1126 Communication System: UID 0, CW; Frequency: 2600 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2600 MHz; σ = 2.203 S/m; εr = 51.338; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-05-2018; Ambient Temp: 22.7°C; Tissue Temp: 21.3°C Probe: ES3DV3 - SN3319; ConvF(4.33, 4.33, 4.33) @ 2600 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2600 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 11.9 W/kg SAR(1 g) = 5.45 W/kg Deviation(1 g) = 0.74% 0 dB = 7.29 W/kg = 8.63 dBW/kg B45 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2600 MHz; Type: D2600V2; Serial: 1071 Communication System: UID 0, CW; Frequency: 2600 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2600 MHz; σ = 2.22 S/m; εr = 52.401; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 01-07-2019; Ambient Temp: 22.6°C; Tissue Temp: 21.6°C Probe: ES3DV3 - SN3319; ConvF(4.33, 4.33, 4.33) @ 2600 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2600 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 12.2 W/kg SAR(1 g) = 5.52 W/kg Deviation(1 g) = 1.85% 0 dB = 7.32 W/kg = 8.65 dBW/kg B46 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2600 MHz; Type: D2600V2; Serial: 1004 Communication System: UID 0, CW; Frequency: 2600 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2600 MHz; σ = 2.208 S/m; εr = 51.169; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 01-14-2019; Ambient Temp: 22.3°C; Tissue Temp: 21.6°C Probe: ES3DV3 - SN3319; ConvF(4.33, 4.33, 4.33) @ 2600 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2600 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 12.3 W/kg SAR(10 g) = 2.41 W/kg Deviation(10 g) = -2.43% 0 dB = 7.32 W/kg = 8.65 dBW/kg B47 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 3700 MHz; Type: D3700V2; Serial: 1002 Communication System: UID 0, CW; Frequency: 3700 MHz; Duty Cycle: 1:1 Medium: 3700 Body Medium parameters used (interpolated): f = 3700 MHz; σ = 3.412 S/m; εr = 50.772; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-27-2018; Ambient Temp: 22.8°C; Tissue Temp: 20.6°C Probe: EX3DV4 - SN3914; ConvF(6.64, 6.64, 6.64) @ 3700 MHz; Calibrated: 2/14/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V8.0; Type: QD 000 P41 Ax; Serial: 1966 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 3700 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x8)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 18.2 W/kg SAR(1 g) = 6.37 W/kg Deviation(1 g) = -2.00% 0 dB = 12.7 W/kg = 11.04 dBW/kg B48 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5250 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used (interpolated): f = 5250 MHz; σ = 5.498 S/m; εr = 49.404; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-11-2018; Ambient Temp: 22.5°C; Tissue Temp: 21.7°C Probe: EX3DV4 - SN7357; ConvF(4.78, 4.78, 4.78) @ 5250 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5250 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 14.3 W/kg SAR(10 g) = 0.976 W/kg Deviation(10 g) = -9.63% 0 dB = 8.56 W/kg = 9.32 dBW/kg B49 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5600 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used: f = 5600 MHz; σ = 5.957 S/m; εr = 48.81; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-11-2018; Ambient Temp: 22.5°C; Tissue Temp: 21.7°C Probe: EX3DV4 - SN7357; ConvF(4.2, 4.2, 4.2) @ 5600 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5600 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 17.3 W/kg SAR(10 g) = 1.08 W/kg Deviation(10 g) = -2.70% 0 dB = 9.79 W/kg = 9.91 dBW/kg B50 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5750 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used (interpolated): f = 5750 MHz; σ = 6.174 S/m; εr = 48.581; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-11-2018; Ambient Temp: 22.5°C; Tissue Temp: 21.7°C Probe: EX3DV4 - SN7357; ConvF(4.21, 4.21, 4.21) @ 5750 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5750 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 16.5 W/kg SAR(10 g) = 0.990 W/kg Deviation(10 g) = -6.60% 0 dB = 8.92 W/kg = 9.50 dBW/kg B51 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5250 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used (interpolated): f = 5250 MHz; σ = 5.413 S/m; εr = 48.971; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-18-2018; Ambient Temp: 23.0°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7357; ConvF(4.78, 4.78, 4.78) @ 5250 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5250 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 14.3 W/kg SAR(1 g) = 3.54 W/kg Deviation(1 g) = -8.05% 0 dB = 8.66 W/kg = 9.38 dBW/kg B52 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5600 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used: f = 5600 MHz; σ = 5.888 S/m; εr = 48.371; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-18-2018; Ambient Temp: 23.0°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7357; ConvF(4.2, 4.2, 4.2) @ 5600 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5600 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 16.9 W/kg SAR(1 g) = 3.84 W/kg Deviation(1 g) = -3.03% 0 dB = 9.29 W/kg = 9.68 dBW/kg B53 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5750 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used (interpolated): f = 5750 MHz; σ = 6.086 S/m; εr = 48.165; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-18-2018; Ambient Temp: 23.0°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7357; ConvF(4.21, 4.21, 4.21) @ 5750 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5750 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 16.5 W/kg SAR(1 g) = 3.6 W/kg Deviation(1 g) = -5.39% 0 dB = 8.80 W/kg = 9.44 dBW/kg B54 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5600 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used: f = 5600 MHz; σ = 5.939 S/m; εr = 47.285; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-26-2018; Ambient Temp: 21.3°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7308; ConvF(4, 4, 4) @ 5600 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1630 Measurement SW: DASY52, Version 52.10; SEMCAD X Version 14.6.12 (7450) 5600 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 17.5 W/kg SAR(1 g) = 3.89 W/kg Deviation(1 g) = -1.77% 0 dB = 9.63 W/kg = 9.84 dBW/kg B55 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5750 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used (interpolated): f = 5750 MHz; σ = 6.154 S/m; εr = 47.01; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-26-2018; Ambient Temp: 21.3°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7308; ConvF(4.18, 4.18, 4.18) @ 5750 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1630 Measurement SW: DASY52, Version 52.10; SEMCAD X Version 14.6.12 (7450) 5750 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 16.1 W/kg SAR(1 g) = 3.47 W/kg Deviation(1 g) = -8.80% 0 dB = 8.59 W/kg = 9.34 dBW/kg B56 APPENDIX C: PROBE CALIBRATION © 2019 PCTEST Engineering Laboratory, Inc. PCTEST ENGINEERING LABORATORY, INC. 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.pctest.com Certification of Calibration Object D1750V2 – SN: 1148 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extended Calibration date: May 09, 2018 Description: SAR Validation Dipole at 1750 MHz. Calibration Equipment used: Manufacturer Model Description Cal Date Cal Interval Cal Due Serial Number Control Company Control Company Amplifier Research Narda Keysight Keysight Technologies Mini-Circuits SPEAG SPEAG SPEAG SPEAG SPEAG Anritsu Anritsu Agilent Mini-Circuits Pasternack Agilent Pasternack Anritsu 4040 4352 15S1G6 4772-3 772D 85033E BW-N20W5+ DAE4 DAE4 DAK-3.5 ES3DV3 ES3DV3 MA2411B MA2411B N5182A NLP-2950+ PE2209-10 8753ES NC-100 ML2495A Therm./Clock/Humidity Monitor Ultra Long Stem Thermometer Amplifier Attenuator (3dB) Dual Directional Coupler Standard Mechanical Calibration Kit (DC to 9GHz, 3.5mm) DC to 18 GHz Precision Fixed 20 dB Attenuator Dasy Data Acquisition Electronics Dasy Data Acquisition Electronics Dielectric Assessment Kit SAR Probe SAR Probe Pulse Power Sensor Pulse Power Sensor MXG Vector Signal Generator Low Pass Filter DC to 2700 MHz Bidirectional Coupler S-Parameter Network Analyzer Torque Wrench Power Meter 3/31/2017 5/2/2017 CBT CBT CBT 6/1/2017 CBT 2/9/2018 6/21/2017 9/12/2017 9/18/2017 2/13/2018 3/2/2018 3/2/2018 4/18/2018 CBT CBT 9/14/2017 4/18/2018 10/22/2017 Biennial Biennial N/A N/A N/A Annual N/A Annual Annual Annual Annual Annual Annual Annual Annual N/A N/A Annual Annual Annual 3/31/2019 5/2/2019 CBT CBT CBT 6/1/2018 CBT 2/9/2019 6/21/2018 9/12/2018 9/18/2018 2/13/2019 3/2/2019 3/2/2019 4/18/2019 CBT CBT 9/14/2018 4/18/2019 10/22/2018 170232394 170330156 433971 9406 MY52180215 MY53401181 N/A 1272 1333 1091 3287 3213 1207364 1339018 MY47420800 N/A N/A US39170118 1445 941001 Measurement Uncertainty = ±23% (k=2) Name Function Calibrated By: Brodie Halbfoster Test Engineer Approved By: Kaitlin O’Keefe Senior Technical Manager Object: Date Issued: D1750V2 – SN: 1148 05/09/2018 Signature Page 1 of 4 DIPOLE CALIBRATION EXTENSION Per KDB 865664 D01, calibration intervals of up to three years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained stable according to the following requirements: 1. The measured SAR does not deviate more than 10% from the target on the calibration certificate. 2. The return-loss does not deviate more than 20% from the previous measurement and meets the required 20dB minimum return-loss requirement. 3. The measurement of real or imaginary parts of impedance does not deviate more than 5Ω from the previous measurement. The following dipole was checked to pass the above 3 requirements to have 2-year calibration period from the calibration date: Certificate Electrical Delay (ns) Calibration Date Extension Date 5/9/2017 5/9/2018 1.223 Calibration Date Extension Date Certificate Electrical Delay (ns) 5/9/2017 5/9/2018 1.223 Certificate Measured SAR Target Head SAR (1g) Head (1g) W/kg @ 20.0 W/kg @ 20.0 dBm dBm 3.64 3.59 Certificate Measured SAR Target Body SAR (1g) Body (1g) W/kg @ 20.0 W/kg @ 20.0 dBm dBm 3.7 3.88 Deviation 1g (%) -1.37% Deviation 1g (%) 4.86% Certificate Measured SAR Target Head SAR Deviation 10g Head (10g) (10g) W/kg @ (%) W/kg @ 20.0 20.0 dBm dBm 1.93 1.91 -1.04% Certificate Measured SAR Target Body SAR Deviation 10g Body (10g) (10g) W/kg @ (%) W/kg @ 20.0 20.0 dBm dBm 1.98 2.06 4.04% Object: Date Issued: D1750V2 – SN: 1148 05/09/2018 Certificate Impedance Head (Ohm) Real Measured Impedance Head (Ohm) Real Difference (Ohm) Real Certificate Impedance Head (Ohm) Imaginary Measured Impedance Head (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Head (dB) Measured Return Loss Head (dB) Deviation (%) PASS/FAIL 49.8 49.0 0.8 -0.7 0.1 0.8 -42.9 -38.7 9.90% PASS Certificate Impedance Body (Ohm) Real Measured Impedance Body (Ohm) Real Difference (Ohm) Real Certificate Impedance Body (Ohm) Imaginary Measured Impedance Body (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Body (dB) Measured Return Loss Body (dB) Deviation (%) PASS/FAIL 45.7 45.4 0.3 -0.5 -2.6 2.1 -26.9 -25.0 7.20% PASS Page 2 of 4 Impedance & Return-Loss Measurement Plot for Head TSL Object: Date Issued: D1750V2 – SN: 1148 05/09/2018 Page 3 of 4 Impedance & Return-Loss Measurement Plot for Body TSL Object: Date Issued: D1750V2 – SN: 1148 05/09/2018 Page 4 of 4 PCTEST ENGINEERING LABORATORY, INC. 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.pctest.com Certification of Calibration Object D2450V2 – SN: 719 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extended Calibration date: 07/18/2018 Description: SAR Validation Dipole at 2450 MHz. Calibration Equipment used: Manufacturer Model Description Cal Date Cal Interval Cal Due Serial Number Agilent Agilent Amplifier Research Anritsu Anritsu Anritsu Control Company Control Company Keysight Keysight Technologies Mini-Circuits Mini-Circuits Narda Pasternack Pasternack SPEAG SPEAG SPEAG SPEAG SPEAG E4438C 8753ES 15S1G6 ML2495A MA2411B MA2411B 4040 4352 772D 85033E BW-N20W5+ NLP-2950+ 4772-3 PE2209-10 PE5011-1 DAE4 DAE4 DAK-3.5 ES3DV3 ES3DV3 ESG Vector Signal Generator S-Parameter Network Analyzer Amplifier Power Meter Pulse Power Sensor Pulse Power Sensor Therm./Clock/Humidity Monitor Ultra Long Stem Thermometer Dual Directional Coupler Standard Mechanical Calibration Kit (DC to 9GHz, 3.5mm) DC to 18 GHz Precision Fixed 20 dB Attenuator Low Pass Filter DC to 2700 MHz Attenuator (3dB) Bidirectional Coupler Torque Wrench Dasy Data Acquisition Electronics Dasy Data Acquisition Electronics Dielectric Assessment Kit SAR Probe SAR Probe 3/24/2017 9/14/2017 CBT 11/28/2017 3/2/2018 11/15/2017 3/31/2017 5/2/2017 CBT 6/4/2018 CBT CBT CBT CBT 7/19/2017 3/7/2018 8/9/2017 9/12/2017 3/13/2018 8/14/2017 Biennial Annual N/A Annual Annual Annual Biennial Biennial N/A Annual N/A N/A N/A N/A Biennial Annual Annual Annual Annual Annual 3/24/2019 9/14/2018 CBT 11/28/2018 3/2/2019 11/15/2018 3/31/2019 5/2/2019 CBT 6/4/2019 CBT CBT CBT CBT 7/19/2019 3/7/2019 8/9/2018 9/12/2018 3/13/2019 8/14/2018 MY42082385 US39170118 433971 1039008 1207364 1339007 170232394 170330156 MY52180215 MY53401181 N/A N/A 9406 N/A N/A 1368 1323 1091 3319 3332 Measurement Uncertainty = ±23% (k=2) Name Function Calibrated By: Brodie Halbfoster Test Engineer Approved By: Kaitlin O’Keefe Senior Technical Manager Object: Date Issued: D2450V2 – SN: 719 07/18/2018 Signature Page 1 of 4 DIPOLE CALIBRATION EXTENSION Per KDB 865664 D01, calibration intervals of up to three years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained stable according to the following requirements: 1. The measured SAR does not deviate more than 10% from the target on the calibration certificate. 2. The return-loss does not deviate more than 20% from the previous measurement and meets the required 20dB minimum return-loss requirement. 3. The measurement of real or imaginary parts of impedance does not deviate more than 5Ω from the previous measurement. The following dipole was checked to pass the above 3 requirements to have 2-year calibration period from the calibration date: Certificate Electrical Delay (ns) Calibration Date Extension Date 8/17/2017 7/18/2018 1.150 Calibration Date Extension Date Certificate Electrical Delay (ns) 8/17/2017 7/18/2018 1.150 Certificate Measured SAR Target Head SAR (1g) Head (1g) W/kg @ 20.0 W/kg @ 20.0 dBm dBm 5.19 5.46 Certificate Measured SAR Target Body SAR (1g) Body (1g) W/kg @ 20.0 W/kg @ 20.0 dBm dBm 5.01 5.19 Deviation 1g (%) 5.20% Deviation 1g (%) 3.59% Certificate Measured SAR Target Head SAR Deviation 10g Head (10g) (10g) W/kg @ (%) W/kg @ 20.0 20.0 dBm dBm 2.43 2.51 3.29% Certificate Measured SAR Target Body SAR Deviation 10g Body (10g) (10g) W/kg @ (%) W/kg @ 20.0 20.0 dBm dBm 2.37 2.38 0.42% Object: Date Issued: D2450V2 – SN: 719 07/18/2018 Certificate Impedance Head (Ohm) Real Measured Impedance Head (Ohm) Real Difference (Ohm) Real Certificate Impedance Head (Ohm) Imaginary Measured Impedance Head (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Head (dB) Measured Return Loss Head (dB) Deviation (%) PASS/FAIL 55.7 53.9 1.8 7.0 2.9 4.1 -21.4 -25.4 -18.70% PASS Certificate Impedance Body (Ohm) Real Measured Impedance Body (Ohm) Real Difference (Ohm) Real Certificate Impedance Body (Ohm) Imaginary Measured Impedance Body (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Body (dB) Measured Return Loss Body (dB) Deviation (%) PASS/FAIL 51.4 50.2 1.2 8.1 5.9 2.2 -21.8 -24.6 -12.80% PASS Page 2 of 4 Impedance & Return-Loss Measurement Plot for Head TSL Object: Date Issued: D2450V2 – SN: 719 07/18/2018 Page 3 of 4 Impedance & Return-Loss Measurement Plot for Body TSL Object: Date Issued: D2450V2 – SN: 719 07/18/2018 Page 4 of 4
Source Exif Data [exif.tools]:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Create Date : 2019:01:31 09:11:15-05:00 Creator : Microsoft® Word for Office 365 Modify Date : 2019:01:31 09:12:28-05:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Metadata Date : 2019:01:31 09:12:28-05:00 Creator Tool : Microsoft® Word for Office 365 Format : application/pdf Document ID : uuid:c3fe0dbc-5e59-4468-a7ec-78dad2d7a41e Instance ID : uuid:e934ac47-1885-4e8f-9912-eebf5e10cc8b Producer : Microsoft® Word for Office 365 Page Count : 214