SMG975U Multi-band GSM/EDGE/CDMA/UMTS/LTE Phone with Bluetooth, WLAN, RFID and ANT+ RF Exposure Info SAR Report 2 Samsung Electronics Co Ltd
Samsung Electronics Co Ltd Multi-band GSM/EDGE/CDMA/UMTS/LTE Phone with Bluetooth, WLAN, RFID and ANT+
PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0509M Communication System: UID 0, LTE Band 48; Frequency: 3690 MHz; Duty Cycle: 1:1.58 Medium: 3500-3700 Body Medium parameters used (interpolated): f = 3690 MHz; σ = 3.401 S/m; εr = 50.781; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-27-2018; Ambient Temp: 22.8°C; Tissue Temp: 20.6°C Probe: EX3DV4 - SN3914; ConvF(6.64, 6.64, 6.64) @ 3690 MHz; Calibrated: 2/14/2018; Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V8.0; Type: QD 000 P41 Ax; Serial: 1966 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: LTE Band 48, Body SAR, Back side, High.ch, 20 MHz Bandwidth, QPSK, 1 RB, 0 RB Offset Area Scan (10x18x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x8)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=1.4mm; Graded Ratio: 1.4 Reference Value = 5.400 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 0.227 W/kg SAR(1 g) = 0.089 W/kg A60 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0509M Communication System: UID 0, _LTE Band 48; Frequency: 3560 MHz; Duty Cycle: 1:1.58 Medium: 3500-3700 Body Medium parameters used (interpolated): f = 3560 MHz; σ = 3.248 S/m; εr = 51.016; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-27-2018; Ambient Temp: 22.8°C; Tissue Temp: 20.6°C Probe: EX3DV4 - SN3914; ConvF(6.81, 6.81, 6.81) @ 3560 MHz; Calibrated: 2/14/2018; Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V8.0; Type: QD 000 P41 Ax; Serial: 1966 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: LTE Band 48, Body SAR, Bottom Edge, Low.ch, 20 MHz Bandwidth, QPSK, 50 RB, 50 RB Offset Area Scan (10x9x1): Measurement grid: dx=5mm, dy=12mm Zoom Scan (7x7x8)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=1.4mm; Graded Ratio: 1.4 Reference Value = 8.052 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 0.502 W/kg SAR(1 g) = 0.189 W/kg A61 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0321M Communication System: UID 0, _LTE Band 41 (Class 2); Frequency: 2549.5 MHz; Duty Cycle: 1:2.31 Medium: 2450 Body Medium parameters used: f = 2550 MHz; σ = 2.156 S/m; εr = 52.545; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 01-07-2019; Ambient Temp: 22.6°C; Tissue Temp: 21.6°C Probe: ES3DV3 - SN3319; ConvF(4.33, 4.33, 4.33) @ 2549.5 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: LTE Band 41 PC2 ULCA, Body SAR, Back side, Low-Mid.ch, PCC: 20 MHz Bandwidth, QPSK, Ch. 40185, 1 RB, 0 RB Offset SCC: 20 MHz Bandwidth, QPSK, Ch. 39987, 1 RB, 99 RB Offset Area Scan (10x16x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 17.32 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 1.09 W/kg SAR(1 g) = 0.566 W/kg A62 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0482M Communication System: UID 0, _LTE Band 41; Frequency: 2636.5 MHz; Duty Cycle: 1:1.58 Medium: 2450 Body Medium parameters used (interpolated): f = 2636.5 MHz; σ = 2.216 S/m; εr = 51.688; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-09-2018; Ambient Temp: 21.8°C; Tissue Temp: 22.8°C Probe: ES3DV3 - SN3319; ConvF(4.33, 4.33, 4.33) @ 2636.5 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: LTE Band 41 PC3 ULCA, Body SAR, Bottom Edge, PCC: 20 MHz Bandwidth, QPSK, Ch. 41055, 50 RB, 50 RB Offset SCC: 20 MHz Bandwidth, QPSK, Ch. 41253, 50 RB, 0 RB Offset Area Scan (10x9x1): Measurement grid: dx=5mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 20.43 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 1.97 W/kg SAR(1 g) = 0.923 W/kg A63 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0539M Communication System: UID 0, _IEEE 802.11b; Frequency: 2437 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used (interpolated): f = 2437 MHz; σ = 2.017 S/m; εr = 52.125; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-12-2018; Ambient Temp: 22.7°C; Tissue Temp: 21.0°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2437 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: IEEE 802.11b, Antenna 1, 22 MHz Bandwidth, Body SAR, Ch 6, 1 Mbps, Back Side Area Scan (11x17x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 9.079 V/m; Power Drift = 0.06 dB Peak SAR (extrapolated) = 0.267 W/kg SAR(1 g) = 0.144 W/kg A64 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0539M Communication System: UID 0, _IEEE 802.11b; Frequency: 2437 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used (interpolated): f = 2437 MHz; σ = 2.017 S/m; εr = 52.125; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-12-2018; Ambient Temp: 22.7°C; Tissue Temp: 21.0°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2437 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: IEEE 802.11b, Antenna 2, 22 MHz Bandwidth, Body SAR, Ch 06, 1 Mbps, Top Edge Area Scan (10x11x1): Measurement grid: dx=5mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 11.77 V/m; Power Drift = 0.06 dB Peak SAR (extrapolated) = 0.596 W/kg SAR(1 g) = 0.310 W/kg A65 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0193M Communication System: UID 0, 802.11n 5.2-5.8 GHz Band; Frequency: 5785 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used: f = 5785 MHz; σ = 6.173 S/m; εr = 46.358; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 01-03-2019; Ambient Temp: 21.5°C; Tissue Temp: 21.0°C Probe: EX3DV4 - SN7308; ConvF(4.18, 4.18, 4.18) @ 5785 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1630 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: IEEE 802.11n, UNII-3, MIMO, 20 MHz Bandwidth, Body SAR, Ch 157, 13 Mbps, Back Side Area Scan (9x9x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Reference Value = 8.083 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 1.68 W/kg SAR(1 g) = 0.387 W/kg A66 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0193M Communication System: UID 0, 802.11n 5.2-5.8 GHz Band; Frequency: 5785 MHz; Duty Cycle: 1:1 Medium: 5GHz Body Medium parameters used: f = 5785 MHz; σ = 6.207 S/m; εr = 46.757; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-03-2018; Ambient Temp: 23.0°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7357; ConvF(4.21, 4.21, 4.21) @ 5785 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: IEEE 802.11n, UNII-3, MIMO, 20 MHz Bandwidth, Body SAR, Ch 157, 13 Mbps, Back Side Area Scan (13x22x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Reference Value = 11.66 V/m; Power Drift = 0.21 dB Peak SAR (extrapolated) = 3.01 W/kg SAR(1 g) = 0.752 W/kg A67 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0486M Communication System: UID 0, Bluetooth; Frequency: 2441 MHz; Duty Cycle: 1:1.297 Medium: 2450 Body Medium parameters used (interpolated): f = 2441 MHz; σ = 2.034 S/m; εr = 51.047; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-14-2018; Ambient Temp: 21.9°C; Tissue Temp: 22.5°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2441 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: Bluetooth, Body SAR, Ch 39, 1 Mbps, Back Side Area Scan (11x17x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 7.082 V/m; Power Drift = 0.20 dB Peak SAR (extrapolated) = 0.180 W/kg SAR(1 g) = 0.092 W/kg A68 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0486M Communication System: UID 0, Bluetooth; Frequency: 2441 MHz; Duty Cycle: 1:1.297 Medium: 2450 Body Medium parameters used (interpolated): f = 2441 MHz; σ = 2.034 S/m; εr = 51.047; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-14-2018; Ambient Temp: 21.9°C; Tissue Temp: 22.5°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2441 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: Bluetooth, Body SAR, Ch 39, 1 Mbps, Left Edge Area Scan (10x16x1): Measurement grid: dx=5mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 10.86 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 0.413 W/kg SAR(1 g) = 0.207 W/kg A69 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0503M Communication System: UID 0, _GSM GPRS; 3 Tx slots; Frequency: 1909.8 MHz; Duty Cycle: 1:2.76 Medium: 1900 Body Medium parameters used: f = 1910 MHz; σ = 1.57 S/m; εr = 51.1; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 0.0 cm Test Date: 12-12-2018; Ambient Temp: 23.6°C; Tissue Temp: 22.0°C Probe: ES3DV3 - SN3332; ConvF(4.77, 4.77, 4.77) @ 1909.8 MHz; Calibrated: 8/22/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: GPRS 1900, Phablet SAR, Bottom Edge, High.ch, 3 Tx Slots Area Scan (10x9x1): Measurement grid: dx=5mm, dy=15mm Zoom Scan (5x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 68.33 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 12.6 W/kg SAR(10 g) = 2.54 W/kg A70 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0503M Communication System: UID 0, UMTS; Frequency: 1752.6 MHz; Duty Cycle: 1:1 Medium: 1750 Body Medium parameters used (interpolated): f = 1752.6 MHz; σ = 1.493 S/m; εr = 50.855; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 0 cm Test Date: 11-18-2018; Ambient Temp: 19.9°C; Tissue Temp: 21.0°C Probe: ES3DV3 - SN3347; ConvF(5.17, 5.17, 5.17) @ 1752.6 MHz; Calibrated: 3/27/2018; Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn665; Calibrated: 2/15/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1800 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: UMTS 1750, Phablet SAR, Bottom Edge, High.ch Area Scan (10x9x1): Measurement grid: dx=5mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 64.95 V/m; Power Drift = -0.08 dB Peak SAR (extrapolated) = 10.5 W/kg SAR(10 g) = 2.21 W/kg A71 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0503M Communication System: UID 0, UMTS; Frequency: 1880 MHz; Duty Cycle: 1:1 Medium: 1900 Body Medium parameters used: f = 1880 MHz; σ = 1.524 S/m; εr = 51.536; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 0 cm Test Date: 11-19-2018; Ambient Temp: 24.4°C; Tissue Temp: 21.8°C Probe: ES3DV3 - SN3213; ConvF(4.88, 4.88, 4.88) @ 1880 MHz; Calibrated: 2/13/2018; Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: UMTS 1900, Phablet SAR, Bottom Edge, Mid.ch Area Scan (11x9x1): Measurement grid: dx=5mm, dy=15mm Zoom Scan (5x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 63.00 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 10.8 W/kg SAR(10 g) = 2.32 W/kg A72 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0503M Communication System: UID 0, CDMA; Frequency: 1880 MHz; Duty Cycle: 1:1 Medium: 1900 Body Medium parameters used: f = 1880 MHz; σ = 1.529 S/m; εr = 51.157; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 0.0 cm Test Date: 12-12-2018; Ambient Temp: 23.6°C; Tissue Temp: 22.0°C Probe: ES3DV3 - SN3332; ConvF(4.77, 4.77, 4.77) @ 1880 MHz; Calibrated: 8/22/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: PCS EVDO, Phablet SAR, Bottom Edge, Mid.ch Area Scan (10x9x1): Measurement grid: dx=5mm, dy=15mm Zoom Scan (5x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 64.74 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 11.0 W/kg SAR(10 g) = 2.3 W/kg A73 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0495M Communication System: UID 0, LTE Band 66 (AWS); Frequency: 1720 MHz; Duty Cycle: 1:1 Medium: 1750 Body Medium parameters used (interpolated): f = 1720 MHz; σ = 1.425 S/m; εr = 53.77; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 0.0 cm Test Date: 12-10-2018; Ambient Temp: 19.9 C; Tissue Temp: 20.4°C Probe: ES3DV3 - SN3347; ConvF(5.17, 5.17, 5.17) @ 1720 MHz; Calibrated: 3/27/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn665; Calibrated: 2/15/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1800 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: LTE Band 66 (AWS) ULCA, Phablet SAR, Bottom Edge, PCC: 20 MHz Bandwidth, QPSK, Ch. 132072, 50 RB, 50 RB Offset SCC: 20 MHz Bandwidth, QPSK, Ch. 132270, 50 RB, 0 RB Offset Area Scan (11x7x1): Measurement grid: dx=5mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 57.93 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 7.99 W/kg SAR(10 g) = 1.69 W/kg A74 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0495M Communication System: UID 0, LTE Band 25 (PCS); Frequency: 1882.5 MHz; Duty Cycle: 1:1 Medium: 1900 Body Medium parameters used (interpolated): f = 1882.5 MHz; σ = 1.553 S/m; εr = 51.077; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 0.0 cm Test Date: 12-05-2018; Ambient Temp: 24.5°C; Tissue Temp: 23.3°C Probe: ES3DV3 - SN3332; ConvF(4.77, 4.77, 4.77) @ 1882.5 MHz; Calibrated: 8/22/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: LTE Band 25 (PCS), Phablet SAR, Bottom Edge, Mid.ch, 20 MHz Bandwidth, QPSK, 50 RB, 0 RB Offset Area Scan (10x13x1): Measurement grid: dx=5mm, dy=15mm Zoom Scan (5x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 72.47 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 14.4 W/kg SAR(10 g) = 2.96 W/kg A75 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0509M Communication System: UID 0, LTE Band 30; Frequency: 2310 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2310 MHz; σ = 1.887 S/m; εr = 51.033; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 0 cm Test Date: 11-20-2018; Ambient Temp: 23.2°C; Tissue Temp: 23.5°C Probe: ES3DV3 - SN3319; ConvF(4.63, 4.63, 4.63) @ 2310 MHz; Calibrated: 3/13/2018; Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: LTE Band 30, Phablet SAR, Bottom Edge, Mid.ch, 10 MHz Bandwidth, QPSK, 1 RB, 0 RB Offset Area Scan (11x10x1): Measurement grid: dx=5mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 46.45 V/m; Power Drift = -0.12 dB Peak SAR (extrapolated) = 11.4 W/kg SAR(10 g) = 1.14 W/kg A76 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0509M Communication System: UID 0, LTE Band 7; Frequency: 2510 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used (interpolated): f = 2510 MHz; σ = 2.11 S/m; εr = 51.683; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 0.0 cm Test Date: 12-02-2018; Ambient Temp: 21.6°C; Tissue Temp: 23.3°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2510 MHz; Calibrated: 3/13/2018; Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: LTE Band 7, Antenna B, Phablet SAR, Bottom Edge, Low.ch, 20 MHz Bandwidth, QPSK, 100 RB, 0 RB Offset Area Scan (10x11x1): Measurement grid: dx=5mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 61.07 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 22.5 W/kg SAR(10 g) = 1.83 W/kg A77 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0509M Communication System: UID 0, _LTE Band 48; Frequency: 3560 MHz; Duty Cycle: 1:1.58 Medium: 3500-3700 Body Medium parameters used (interpolated): f = 3560 MHz; σ = 3.248 S/m; εr = 51.016; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 0.0 cm Test Date: 11-27-2018; Ambient Temp: 22.8°C; Tissue Temp: 20.6°C Probe: EX3DV4 - SN3914; ConvF(6.81, 6.81, 6.81) @ 3560 MHz; Calibrated: 2/14/2018; Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V8.0; Type: QD 000 P41 Ax; Serial: 1966 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: LTE Band 48, Phablet SAR, Bottom Edge, Low.ch, 20 MHz Bandwidth, QPSK, 50 RB, 50 RB Offset Area Scan (10x10x1): Measurement grid: dx=5mm, dy=12mm Zoom Scan (9x9x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Reference Value = 33.46 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 12.2 W/kg SAR(10 g) = 0.830 W/kg A78 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0482M Communication System: UID 0, LTE Band 41 (Class 3); Frequency: 2680 MHz; Duty Cycle: 1:1.58 Medium: 2450 Body Medium parameters used: f= 2680 MHz; σ = 2.305 S/m; εr = 51.138; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 0.0 cm Test Date: 12-05-2018; Ambient Temp: 22.7°C; Tissue Temp: 21.3°C Probe: ES3DV3 - SN3319; ConvF(4.33, 4.33, 4.33) @ 2680 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: LTE Band 41 PC3 ULCA, Phablet SAR, Bottom Edge, PCC: 20 MHz Bandwidth, QPSK, Ch. 41490, 1 RB, 0 RB Offset SCC: 20 MHz Bandwidth, QPSK, Ch. 41292, 1 RB, 99 RB Offset Area Scan (10x9x1): Measurement grid: dx=5mm, dy=12mm Zoom Scan (8x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 49.70 V/m; Power Drift = -0.17 dB Peak SAR (extrapolated) = 27.1 W/kg SAR(10 g) = 2.11 W/kg A79 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0486M Communication System: UID 0, 802.11n 5.2-5.8 GHz Band; Frequency: 5600 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used: f = 5600 MHz; σ = 5.888 S/m; εr = 48.371; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 0.0 cm Test Date: 11-18-2018; Ambient Temp: 23.0°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7357; ConvF(4.2, 4.2, 4.2) @ 5600 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: IEEE 802.11n, U-NII-2C, MIMO, 20 MHz Bandwidth, Phablet SAR, Ch 120, 13 Mbps, Back Side Area Scan (13x21x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Reference Value = 56.12 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 114 W/kg SAR(10 g) = 2.38 W/kg A80 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0486M Communication System: UID 0, Bluetooth; Frequency: 2441 MHz; Duty Cycle: 1:1.297 Medium: 2450 Body Medium parameters used (interpolated): f = 2441 MHz; σ = 2.021 S/m; εr = 51.392; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-27-2018; Ambient Temp: 22.5°C; Tissue Temp: 21.9°C Probe: EX3DV4 - SN7406; ConvF(7.3, 7.3, 7.3) @ 2441 MHz; Calibrated: 5/22/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn859; Calibrated: 5/22/2018 Phantom: Twin-SAM V5.0 Back Right; Type: QD 000 P40 CD; Serial: 1692 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: Bluetooth, Body SAR, Ch 39, 1 Mbps, Back Side Zoom Scan (19x16x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 3.849 V/m; Power Drift = 0.15 dB Peak SAR (extrapolated) = 0.278 W/kg SAR(1 g) = 0.152 W/kg A81 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0193M Communication System: UID 0, _IEEE 802.11a; Frequency: 5785 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used: f = 5785 MHz; σ = 6.219 S/m; εr = 46.931; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-26-2018; Ambient Temp: 21.3°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7308; ConvF(4.18, 4.18, 4.18) @ 5785 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1630 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: IEEE 802.11a, UNII-3, Antenna 2, 20 MHz Bandwidth, Body SAR, Ch 157, 6 Mbps, Back Side Zoom Scan (25x19x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Reference Value = 0.4540 V/m; Power Drift = -0.19 dB Peak SAR (extrapolated) = 4.40 W/kg SAR(1 g) = 0.570 W/kg 0 dB = 1.50 W/kg = 1.76 dBW/kg A82 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset; Serial: 0193M Communication System: UID 0, 802.11n; Frequency: 5825 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used: f = 5825 MHz; σ = 6.274 S/m; εr = 46.853; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-26-2018; Ambient Temp: 21.3°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7308; ConvF(4.18, 4.18, 4.18) @ 5825 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1630 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) Mode: IEEE 802.11n, UNII-3, MIMO, 20 MHz Bandwidth, Body SAR, Ch 165, 13 Mbps, Back Side Zoom Scan (25x19x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Reference Value = 1.553 V/m; Power Drift = -0.20 dB Peak SAR (extrapolated) = 6.36 W/kg SAR(1 g) = 0.658 W/kg 0 dB = 1.65 W/kg = 2.17 dBW/kg A83 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset Mode: IEEE 802.11a, U-NII-3, Antenna 2, 20 MHz Bandwidth, Body SAR, Ch 157, 6 Mbps, Back Side, Scaling Factor: 1.156 Communication System: UID 0, 802.11a 5.2-5.8 GHz Band; Frequency: 5785 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used: f = 5785 MHz; σ = 6.219 S/m; εr = 46.931; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Mode: Bluetooth, Body SAR, Ch 39, 1 Mbps, Back Side, Scaling Factor: 1.336 Communication System: UID 0, Bluetooth; Frequency: 2441 MHz; Duty Cycle: 1:1.297 Medium: 2450 Body Medium parameters used (interpolated): f = 2441 MHz; σ = 2.021 S/m; εr = 51.392; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Multi Band Result: SAR(1 g) = 0.850 W/kg 0 dB = 3.16 W/kg = 5.00 dBW/kg A84 PCTEST ENGINEERING LABORATORY, INC. DUT: A3LSMG975U; Type: Portable Handset Mode: IEEE 802.11n, U-NII-3, MIMO, 20 MHz Bandwidth, Body SAR, Ch 165, 13 Mbps, Back Side, Scaling Factor: 1.176 Communication System: UID 0, 802.11n 5.2-5.8 GHz Band; Frequency: 5825 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used: f = 5825 MHz; σ = 6.274 S/m; εr = 46.853; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Mode: Bluetooth, Body SAR, Ch 39, 1 Mbps, Back Side, Scaling Factor: 1.336 Communication System: UID 0, Bluetooth; Frequency: 2441 MHz; Duty Cycle: 1:1.297 Medium: 2450 Body Medium parameters used (interpolated): f = 2441 MHz; σ = 2.021 S/m; εr = 51.392; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Multi Band Result: SAR(1 g) = 0.964 W/kg 0 dB = 3.57 W/kg = 5.53 dBW/kg A85 APPENDIX B: SYSTEM VERIFICATION © 2019 PCTEST Engineering Laboratory, Inc. PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 750 MHz; Type: D750V3; Serial: 1054 Communication System: UID 0, CW; Frequency: 750 MHz; Duty Cycle: 1:1 Medium: 750 Head; Medium parameters used (interpolated): f = 750 MHz; σ = 0.893 S/m; εr = 42.634; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-15-2018; Ambient Temp: 21.8°C; Tissue Temp: 20.6°C Probe: EX3DV4 - SN7406; ConvF(10.09, 10.09, 10.09) @ 750 MHz; Calibrated: 5/22/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn859; Calibrated: 5/22/2018 Phantom: Twin-SAM V4.0 Front Right; Type: QD 000 P40 CC; Serial: 1167 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 750 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x15x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 2.45 W/kg SAR(1 g) = 1.63 W/kg Deviation(1 g) = -2.63% 0 dB = 2.18 W/kg = 3.38 dBW/kg B1 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 750 MHz; Type: D750V3; Serial: 1003 Communication System: UID 0, CW; Frequency: 750 MHz; Duty Cycle: 1:1 Medium: 750 Head; Medium parameters used (interpolated): f = 750 MHz; σ = 0.884 S/m; εr = 40.485; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 12-10-2018; Ambient Temp: 22.3°C; Tissue Temp: 20.5°C Probe: ES3DV3 - SN3287; ConvF(6.76, 6.76, 6.76) @ 750 MHz; Calibrated: 10/22/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1333; Calibrated: 10/18/2018 Phantom: Twin-SAM V8.0; Type: QD 000 P41 Ax; Serial: 1964 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 750 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x15x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 2.44 W/kg SAR(1 g) = 1.63 W/kg Deviation(1 g) = -1.57% 0 dB = 1.91 W/kg = 2.81 dBW/kg B2 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d047 Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1 Medium: 835 Head Medium parameters used: f = 835 MHz; σ = 0.895 S/m; εr = 43.164; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-13-2018; Ambient Temp: 18.9°C; Tissue Temp: 19.7°C Probe: EX3DV4 - SN7308; ConvF(9.96, 9.96, 9.96) @ 835 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1630 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 835 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 2.83 W/kg SAR(1 g) = 1.88 W/kg Deviation(1 g) = -0.74% 0 dB = 2.51 W/kg = 4.00 dBW/kg B3 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d047 Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1 Medium: 835 Head Medium parameters used: f = 835 MHz; σ = 0.907 S/m; εr = 42.361; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-19-2018; Ambient Temp: 23.3°C; Tissue Temp: 22.4°C Probe: EX3DV4 - SN7308; ConvF(9.96, 9.96, 9.96) @ 835 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1630 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 835 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 2.85 W/kg SAR(1 g) = 1.86 W/kg Deviation(1 g) = -1.80% 0 dB = 2.49 W/kg = 3.96 dBW/kg B4 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d133 Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1 Medium: 835 Head Medium parameters used: f = 835 MHz; σ = 0.911 S/m; εr = 41.309; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-23-2018; Ambient Temp: 20.3°C; Tissue Temp: 19.5°C Probe: EX3DV4 - SN7308; ConvF(9.96, 9.96, 9.96) @ 835 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1630 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450)) 835 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 3.03 W/kg SAR(1 g) = 2.02 W/kg Deviation(1 g) = 7.10% 0 dB = 2.70 W/kg = 4.31 dBW/kg B5 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1750 MHz; Type: D1750V2; Serial: 1150 Communication System: UID 0, CW; Frequency: 1750 MHz; Duty Cycle: 1:1 Medium: 1750 Head; Medium parameters used: f = 1750 MHz; σ = 1.347 S/m; εr = 39.501; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-26-2018; Ambient Temp: 20.7°C; Tissue Temp: 21.6°C Probe: ES3DV3 - SN3287; ConvF(5.48, 5.48, 5.48) @ 1750 MHz; Calibrated: 10/22/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1333; Calibrated: 10/18/2018 Phantom: Twin-SAM V8.0; Type: QD 000 P41 Ax; Serial: 1964 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1750 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 6.45 W/kg SAR(1 g) = 3.57 W/kg Deviation(1 g) = -2.19% 0 dB = 4.50 W/kg = 6.53 dBW/kg B6 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1750 MHz; Type: D1750V2; Serial: 1150 Communication System: UID 0, CW; Frequency: 1750 MHz; Duty Cycle: 1:1 Medium: 1750 Head; Medium parameters used: f = 1750 MHz; σ = 1.34 S/m; εr = 38.399; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-10-2018; Ambient Temp: 22.3°C; Tissue Temp: 20.5°C Probe: ES3DV3 - SN3287; ConvF(5.48, 5.48, 5.48) @ 1750 MHz; Calibrated: 10/22/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1333; Calibrated: 10/18/2018 Phantom: Twin-SAM V8.0; Type: QD 000 P41 Ax; Serial: 1964 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1750 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 6.66 W/kg SAR(1 g) = 3.68 W/kg Deviation(1 g) = 0.82% 0 dB = 4.59 W/kg = 6.62 dBW/kg B7 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Head Medium parameters used (interpolated): f = 1900 MHz; σ = 1.452 S/m; εr = 41.191; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-12-2018; Ambient Temp: 22.5°C; Tissue Temp: 21.0°C Probe: ES3DV3 - SN3213; ConvF(5.3, 5.3, 5.3) @ 1900 MHz; Calibrated: 2/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM 5.0 front; Type: QD000P40CD; Serial: 1648 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x10x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 7.43 W/kg SAR(1 g) = 3.98 W/kg Deviation(1 g) = -0.75% 0 dB = 5.04 W/kg = 7.02 dBW/kg B8 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Head; Medium parameters used (interpolated): f = 1900 MHz; σ = 1.442 S/m; εr = 38.957; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-03-2018; Ambient Temp: 21.7°C; Tissue Temp: 20.5°C Probe: ES3DV3 - SN3287; ConvF(5.24, 5.24, 5.24) @ 1900 MHz; Calibrated: 10/22/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1333; Calibrated: 10/18/2018 Phantom: Twin-SAM V8.0; Type: QD 000 P41 Ax; Serial: 1964 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x10x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 7.65 W/kg SAR(1 g) = 4.2 W/kg Deviation(1 g) = 4.74% 0 dB = 5.21 W/kg = 7.17 dBW/kg B9 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2300 MHz; Type: D2300V2; Serial: 1073 Communication System: UID 0, CW; Frequency: 2300 MHz; Duty Cycle: 1:1 Medium: 2450 Head Medium parameters used: f = 2300 MHz; σ = 1.704 S/m; εr = 39.167; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-16-2018; Ambient Temp: 22.4°C; Tissue Temp: 23.1°C Probe: EX3DV4 - SN7410; ConvF(7.78, 7.78, 7.78) @ 2300 MHz; Calibrated: 7/20/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1322; Calibrated: 7/11/2018 Phantom: SAM Front; Type: SAM; Serial: 1686 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2300 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 9.69 W/kg SAR(1 g) = 4.77 W/kg Deviation(1 g) = -3.05% 0 dB = 7.82 W/kg = 8.93 dBW/kg B10 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 981 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Head Medium parameters used: f = 2450 MHz; σ = 1.846 S/m; εr = 38.444; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-18-2018; Ambient Temp: 23.2°C; Tissue Temp: 23.4°C Probe: EX3DV4 - SN7410; ConvF(7.5, 7.5, 7.5) @ 2450 MHz; Calibrated: 7/20/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1322; Calibrated: 7/11/2018 Phantom: SAM Front; Type: SAM; Serial: 1686 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 11.5 W/kg SAR(1 g) = 5.37 W/kg Deviation(1 g) = 2.68% 0 dB = 9.08 W/kg = 9.58 dBW/kg B11 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 797 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Head Medium parameters used: f = 2450 MHz; σ = 1.772 S/m; εr = 38.839; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-28-2018; Ambient Temp: 23.0°C; Tissue Temp: 23.9°C Probe: EX3DV4 - SN7410; ConvF(7.5, 7.5, 7.5) @ 2450 MHz; Calibrated: 7/20/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1322; Calibrated: 7/11/2018 Phantom: SAM Front; Type: SAM; Serial: 1686 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 11.2 W/kg SAR(1 g) = 5.2 W/kg Deviation(1 g) = -1.33% 0 dB = 8.96 W/kg = 9.52 dBW/kg B12 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2600 MHz; Type: D2600V2; Serial: 1071 Communication System: UID 0, CW; Frequency: 2600 MHz; Duty Cycle: 1:1 Medium: 2450 Head Medium parameters used: f = 2600 MHz; σ = 1.937 S/m; εr = 38.35; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-28-2018; Ambient Temp: 23.0°C; Tissue Temp: 23.9°C Probe: EX3DV4 - SN7410; ConvF(7.24, 7.24, 7.24) @ 2600 MHz; Calibrated: 7/20/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1322; Calibrated: 7/11/2018 Phantom: SAM Front; Type: SAM; Serial: 1686 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2600 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 12.1 W/kg SAR(1 g) = 5.39 W/kg Deviation(1 g) = -4.26% 0 dB = 9.36 W/kg = 9.71 dBW/kg B13 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2600 MHz; Type: D2600V2; Serial: 1004 Communication System: UID 0, CW; Frequency: 2600 MHz; Duty Cycle: 1:1 Medium: 2450 Head Medium parameters used: f = 2600 MHz; σ = 1.945 S/m; εr = 39.842; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 01-07-2019; Ambient Temp: 21.7°C; Tissue Temp: 20.8°C Probe: EX3DV4 - SN7410; ConvF(7.24, 7.24, 7.24) @ 2600 MHz; Calibrated: 7/20/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1322; Calibrated: 7/11/2018 Phantom: SAM Front; Type: SAM; Serial: 1686 Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7450) 2600 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 12.0 W/kg SAR(1 g) = 5.59 W/kg Deviation(1 g) = 0.00% 0 dB = 9.53 W/kg = 9.79 dBW/kg B14 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 3500 MHz; Type: D3500V2; Serial: 1055 Communication System: UID 0, CW; Frequency: 3500 MHz; Duty Cycle: 1:1 Medium: 3500 - 3700 Head; Medium parameters used: f = 3500 MHz; σ = 2.924 S/m; εr = 37.356; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-27-2018; Ambient Temp: 22.7°C; Tissue Temp: 21.6°C Probe: EX3DV4 - SN3949; ConvF(7.36, 7.36, 7.36) @ 3500 MHz; Calibrated: 8/24/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1334; Calibrated: 6/18/2018 Phantom: SAM with CRP (Left); Type: SAM; Serial: 1715 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 3500 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x8)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 19.6 W/kg SAR(1 g) = 6.95 W/kg Deviation(1 g) = 4.04% 0 dB = 13.6 W/kg = 11.34 dBW/kg B15 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 3700 MHz; Type: D3700V2; Serial: 1002 Communication System: UID 0, CW; Frequency: 3700 MHz; Duty Cycle: 1:1 Medium: 3500 - 3700 Head; Medium parameters used (interpolated): f = 3700 MHz; σ = 3.081 S/m; εr = 37.138; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-27-2018; Ambient Temp: 22.7°C; Tissue Temp: 21.6°C Probe: EX3DV4 - SN3949; ConvF(7.24, 7.24, 7.24) @ 3700 MHz; Calibrated: 8/24/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1334; Calibrated: 6/18/2018 Phantom: SAM with CRP (Left); Type: SAM; Serial: 1715 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 3700 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x8)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 22.3 W/kg SAR(1 g) = 7.22 W/kg Deviation(1 g) = 6.33% 0 dB = 15.0 W/kg = 11.76 dBW/kg B16 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5250 MHz; Duty Cycle: 1:1 Medium: 5 GHz Head; Medium parameters used (interpolated): f = 5250 MHz; σ = 4.662 S/m; εr = 35.504; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-14-2018; Ambient Temp: 22.3°C; Tissue Temp: 18.7°C Probe: EX3DV4 - SN7409; ConvF(5.2, 5.2, 5.2) @ 5250 MHz; Calibrated: 6/25/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1334; Calibrated: 6/18/2018 Phantom: SAM with CRP v5.0 (Right); Type: QD000P40CD; Serial: TP:1759 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5250 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 16.0 W/kg SAR(1 g) = 3.87 W/kg Deviation(1 g) = -1.90% B17 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5600 MHz; Duty Cycle: 1:1 Medium: 5 GHz Head; Medium parameters used: f = 5600 MHz; σ = 5.02 S/m; εr = 34.927; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-14-2018; Ambient Temp: 22.3°C; Tissue Temp: 18.7°C Probe: EX3DV4 - SN7409; ConvF(4.77, 4.77, 4.77) @ 5600 MHz; Calibrated: 6/25/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1334; Calibrated: 6/18/2018 Phantom: SAM with CRP v5.0 (Right); Type: QD000P40CD; Serial: TP:1759 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5600 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 17.6 W/kg SAR(1 g) = 3.97 W/kg Deviation(1 g) = -5.02% B18 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5750 MHz; Duty Cycle: 1:1 Medium: 5 GHz Head; Medium parameters used (interpolated): f = 5750 MHz; σ = 5.2 S/m; εr = 34.738; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-14-2018; Ambient Temp: 22.3°C; Tissue Temp: 18.7°C Probe: EX3DV4 - SN7409; ConvF(4.82, 4.82, 4.82) @ 5750 MHz; Calibrated: 6/25/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1334; Calibrated: 6/18/2018 Phantom: SAM with CRP v5.0 (Right); Type: QD000P40CD; Serial: TP:1759 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5750 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 18.5 W/kg SAR(1 g) = 4.03 W/kg Deviation(1 g) = 1.90% B19 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 750 MHz; Type: D750V3; Serial: 1054 Communication System: UID 0, CW; Frequency: 750 MHz; Duty Cycle: 1:1 Medium: 750 Body; Medium parameters used (interpolated): f = 750 MHz; σ = 0.966 S/m; εr = 52.992; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-18-2018; Ambient Temp: 21.4°C; Tissue Temp: 20.4°C Probe: EX3DV4 - SN7406; ConvF(9.91, 9.91, 9.91) @ 750 MHz; Calibrated: 5/22/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn859; Calibrated: 5/22/2018 Phantom: Twin-SAM V5.0 Back Right; Type: QD 000 P40 CD; Serial: 1692 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 750 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x15x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 2.75 W/kg SAR(1 g) = 1.78 W/kg Deviation(1 g) = 3.37% 0 dB = 2.42 W/kg = 3.84 dBW/kg B20 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 750 MHz; Type: D750V3; Serial: 1003 Communication System: UID 0, CW; Frequency: 750 MHz; Duty Cycle: 1:1 Medium: 750 Body Medium parameters used (interpolated): f = 750 MHz; σ = 0.951 S/m; εr = 53.291; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-26-2018; Ambient Temp: 22.6°C; Tissue Temp: 20.6°C Probe: EX3DV4 - SN7357; ConvF(10.37, 10.37, 10.37) @ 750 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 750 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x15x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 2.63 W/kg SAR(1 g) = 1.73 W/kg Deviation(1 g) = 0.82% 0 dB = 2.32 W/kg = 3.65 dBW/kg B21 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d047 Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1 Medium: 835 Body Medium parameters used: f = 835 MHz; σ = 0.957 S/m; εr = 53.795; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-14-2018; Ambient Temp: 23.5°C; Tissue Temp: 21.4°C Probe: EX3DV4 - SN7410; ConvF(9.63, 9.63, 9.63) @ 835 MHz; Calibrated: 7/20/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1322; Calibrated: 7/11/2018 Phantom: SAM Front; Type: SAM; Serial: 1686 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 835 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 3.14 W/kg SAR(1 g) = 2.08 W/kg Deviation(1 g) = 7.11% 0 dB = 2.78 W/kg = 4.44 dBW/kg B22 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d047 Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1 Medium: 835 Body; Medium parameters used: f = 835 MHz; σ = 1.018 S/m; εr = 53.976; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-26-2018; Ambient Temp: 19.9°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7406; ConvF(9.61, 9.61, 9.61) @ 835 MHz; Calibrated: 5/22/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn859; Calibrated: 5/22/2018 Phantom: Twin-SAM V4.0 Front Right; Type: QD 000 P40 CC; Serial: 1167 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 835 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 3.17 W/kg SAR(1 g) = 2.1 W/kg Deviation(1 g) = 8.14% 0 dB = 2.80 W/kg = 4.47 dBW/kg B23 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d047 Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1 Medium: 835 Body; Medium parameters used: f = 835 MHz; σ = 0.982 S/m; εr = 53.648; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 11-29-2018; Ambient Temp: 21.4°C; Tissue Temp: 19.9°C Probe: EX3DV4 - SN7406; ConvF(9.61, 9.61, 9.61) @ 835 MHz; Calibrated: 5/22/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn859; Calibrated: 5/22/2018 Phantom: Twin-SAM V4.0 Front Right; Type: QD 000 P40 CC; Serial: 1167 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 835 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 3.12 W/kg SAR(1 g) = 2.04 W/kg Deviation(1 g) = 5.05% 0 dB = 2.75 W/kg = 4.39 dBW/kg B24 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d047 Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1 Medium: 835 Body Medium parameters used: f = 835 MHz; σ = 0.936 S/m; εr = 54.81; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 12-7-2018; Ambient Temp: 19.5 C; Tissue Temp: 19.2°C Probe: ES3DV3 - SN3347; ConvF(6.37, 6.37, 6.37) @ 835 MHz; Calibrated: 3/27/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn665; Calibrated: 2/15/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1800 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 835 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 3.14 W/kg SAR(1 g) = 1.98 W/kg Deviation(1 g) = 1.96% B25 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1750 MHz; Type: D1750V2; Serial: 1148 Communication System: UID 0, CW; Frequency: 1750 MHz; Duty Cycle: 1:1 Medium: 1750 Body Medium parameters used: f = 1750 MHz; σ = 1.526 S/m; εr = 51.976; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-12-2018; Ambient Temp: 19.8°C; Tissue Temp: 21.7°C Probe: ES3DV3 - SN3347; ConvF(5.17, 5.17, 5.17) @ 1750 MHz; Calibrated: 3/27/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn665; Calibrated: 2/15/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1800 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1750 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 6.69 W/kg SAR(1 g) = 3.76 W/kg Deviation(1 g) = 1.62% 0 dB = 4.69 W/kg = 6.71 dBW/kg B26 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1750 MHz; Type: D1750V2; Serial: 1148 Communication System: UID 0, CW; Frequency: 1750 MHz; Duty Cycle: 1:1 Medium: 1750 Body Medium parameters used: f = 1750 MHz; σ = 1.49 S/m; εr = 50.865; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-18-2018; Ambient Temp: 19.9°C; Tissue Temp: 21.0°C Probe: ES3DV3 - SN3347; ConvF(5.17, 5.17, 5.17) @ 1750 MHz; Calibrated: 3/27/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn665; Calibrated: 2/15/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1800 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1750 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 6.64 W/kg SAR(1 g) = 3.73 W/kg; SAR(10 g) = 1.97 W/kg Deviation(1 g) = 0.81%; Deviation(10 g) = -0.51% 0 dB = 4.74 W/kg = 6.76 dBW/kg B27 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1750 MHz; Type: D1750V2; Serial: 1150 Communication System: UID 0, CW; Frequency: 1750 MHz; Duty Cycle: 1:1 Medium: 1750 Body Medium parameters used: f = 1750 MHz; σ = 1.443 S/m; εr = 53.745; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-10-2018; Ambient Temp: 19.9 C; Tissue Temp: 20.4°C Probe: ES3DV3 - SN3347; ConvF(5.17, 5.17, 5.17) @ 1750 MHz; Calibrated: 3/27/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn665; Calibrated: 2/15/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1800 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1750 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 6.28 W/kg SAR(1 g) = 3.61 W/kg; SAR(10 g) = 1.93 W/kg Deviation(1 g) = -1.37%; Deviation(10 g) = -0.52% 0 dB = 4.39 W/kg = 6.42 dBW/kg B28 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body; Medium parameters used (interpolated): f = 1900 MHz; σ = 1.575 S/m; εr = 51.505; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-12-2018; Ambient Temp: 21.8°C; Tissue Temp: 21.0°C Probe: EX3DV4 - SN7409; ConvF(7.6, 7.6, 7.6) @ 1900 MHz; Calibrated: 6/25/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1334; Calibrated: 6/18/2018 Phantom: SAM with CRP (Left); Type: SAM; Serial: 1715 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 7.79 W/kg SAR(1 g) = 4.17 W/kg Deviation(1 g) = 5.30% 0 dB = 6.51 W/kg = 8.14 dBW/kg B29 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body Medium parameters used (interpolated): f = 1900 MHz; σ = 1.579 S/m; εr = 51.286; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-14-2018; Ambient Temp: 23.9°C; Tissue Temp: 21.3°C Probe: ES3DV3 - SN3213; ConvF(4.88, 4.88, 4.88) @ 1900 MHz; Calibrated: 2/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x10x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 7.46 W/kg SAR(1 g) = 4.23 W/kg Deviation(1 g) = 6.82% 0 dB = 5.36 W/kg = 7.29 dBW/kg B30 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body Medium parameters used (interpolated): f = 1900 MHz; σ = 1.583 S/m; εr = 52.049; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-16-2018; Ambient Temp: 24.3°C; Tissue Temp: 21.1°C Probe: ES3DV3 - SN3213; ConvF(4.88, 4.88, 4.88) @ 1900 MHz; Calibrated: 2/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x10x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 6.81 W/kg SAR(1 g) = 3.84 W/kg Deviation(1 g) = -3.03% 0 dB = 4.87 W/kg = 6.88 dBW/kg B31 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body Medium parameters used (interpolated): f = 1900 MHz; σ = 1.545 S/m; εr = 51.477; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-19-2018; Ambient Temp: 24.4°C; Tissue Temp: 21.8°C Probe: ES3DV3 - SN3213; ConvF(4.88, 4.88, 4.88) @ 1900 MHz; Calibrated: 2/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x10x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 6.96 W/kg SAR(1 g) = 3.97 W/kg; SAR(10 g) = 2.06 W/kg Deviation(1 g) = 0.25%; Deviation(10 g) = -1.44% 0 dB = 5.04 W/kg = 7.02 dBW/kg B32 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body Medium parameters used (interpolated): f = 1900 MHz; σ = 1.551 S/m; εr = 51.914; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-21-2018; Ambient Temp: 24.3°C; Tissue Temp: 21.2°C Probe: ES3DV3 - SN3213; ConvF(4.88, 4.88, 4.88) @ 1900 MHz; Calibrated: 2/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x10x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 6.60 W/kg SAR(1 g) = 3.76 W/kg Deviation(1 g) = -5.05% 0 dB = 4.78 W/kg = 6.79 dBW/kg B33 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body; Medium parameters used (interpolated): f = 1900 MHz; σ = 1.58 S/m; εr = 51.197; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-28-2018; Ambient Temp: 21.2°C; Tissue Temp: 20.8°C Probe: ES3DV3 - SN3213; ConvF(4.88, 4.88, 4.88) @ 1900 MHz; Calibrated: 2/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x10x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 6.92 W/kg SAR(1 g) = 3.89 W/kg Deviation(1 g) = -1.77% 0 dB = 4.94 W/kg = 6.94 dBW/kg B34 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body Medium parameters used (interpolated): f = 1900 MHz; σ = 1.572 S/m; εr = 51.023; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-05-2018; Ambient Temp: 24.5°C; Tissue Temp: 23.3°C Probe: ES3DV3 - SN3332; ConvF(4.77, 4.77, 4.77) @ 1900 MHz; Calibrated: 8/22/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x10x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 7.40 W/kg SAR(10 g) = 2.15 W/kg Deviation(10 g) = 2.87% 0 dB = 5.18 W/kg = 7.14 dBW/kg B35 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d149 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body Medium parameters used (interpolated): f = 1900 MHz; σ = 1.565 S/m; εr = 52.735; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-09-2018; Ambient Temp: 21.6°C; Tissue Temp: 21.1°C Probe: ES3DV3 - SN3332; ConvF(4.77, 4.77, 4.77) @ 1900 MHz; Calibrated: 8/22/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x10x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 7.36 W/kg SAR(1 g) = 4.14 W/kg Deviation(1 g) = 5.08% 0 dB = 5.29 W/kg = 7.23 dBW/kg B36 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d080 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Body Medium parameters used (interpolated): f = 1900 MHz; σ = 1.556 S/m; εr = 51.119; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-12-2018; Ambient Temp: 23.6°C; Tissue Temp: 22.0°C Probe: ES3DV3 - SN3332; ConvF(4.77, 4.77, 4.77) @ 1900 MHz; Calibrated: 8/22/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1272; Calibrated: 2/9/2018 Phantom: SAM V5.0 Right; Type: QD000P40CD; Serial: 1647 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x10x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 7.50 W/kg SAR(10 g) = 2.17 W/kg Deviation(10 g) = 5.34% 0 dB = 5.36 W/kg = 7.29 dBW/kg B37 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2300 MHz; Type: D2300V2; Serial: 1073 Communication System: UID 0, CW; Frequency: 2300 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2300 MHz; σ = 1.878 S/m; εr = 51.069; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-20-2018; Ambient Temp: 23.2°C; Tissue Temp: 23.5°C Probe: ES3DV3 - SN3319; ConvF(4.63, 4.63, 4.63) @ 2300 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2300 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 10.0 W/kg SAR(1 g) = 5.08 W/kg; SAR(10 g) = 2.41 W/kg Deviation(1 g) = 6.50%; Deviation(10 g) = 3.88% 0 dB = 6.54 W/kg = 8.16 dBW/kg B38 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 719 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2450 MHz; σ = 2.033 S/m; εr = 52.107; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-12-2018; Ambient Temp: 22.7°C; Tissue Temp: 21.0°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2450 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 10.6 W/kg SAR(1 g) = 5.13 W/kg Deviation(1 g) = 2.40% 0 dB = 6.79 W/kg = 8.32 dBW/kg B39 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 719 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2450 MHz; σ = 2.045 S/m; εr = 51.016; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-14-2018; Ambient Temp: 21.9°C; Tissue Temp: 22.5°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2450 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 10.7 W/kg SAR(1 g) = 5.09 W/kg Deviation(1 g) = 1.60% 0 dB = 6.75 W/kg = 8.29 dBW/kg B40 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 981 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2450 MHz; σ = 2.038 S/m; εr = 51.501; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-26-2018; Ambient Temp: 22.6°C; Tissue Temp: 23.5°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2450 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 10.5 W/kg SAR(1 g) = 5.04 W/kg Deviation(1 g) = -0.98% 0 dB = 6.61 W/kg = 8.20 dBW/kg B41 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 719 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2450 MHz; σ = 2.039 S/m; εr = 51.875; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-02-2018; Ambient Temp: 21.6°C; Tissue Temp: 23.3°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2450 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 10.9 W/kg SAR(1 g) = 5.23 W/kg; SAR(10 g) = 2.41 W/kg Deviation(1 g) = 4.39%; Deviation(10 g) = 1.69% 0 dB = 6.95 W/kg = 8.42 dBW/kg B42 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 719 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2450 MHz; σ = 2.031 S/m; εr = 51.814; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-05-2018; Ambient Temp: 22.7°C; Tissue Temp: 21.3°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2450 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 10.8 W/kg SAR(10 g) = 2.4 W/kg Deviation(10 g) = 1.27% 0 dB = 6.88 W/kg = 8.38 dBW/kg B43 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 719 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2450 MHz; σ = 1.994 S/m; εr = 52.216; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-09-2018; Ambient Temp: 21.8°C; Tissue Temp: 22.8°C Probe: ES3DV3 - SN3319; ConvF(4.51, 4.51, 4.51) @ 2450 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 11.1 W/kg SAR(1 g) = 5.37 W/kg Deviation(1 g) = 7.19% 0 dB = 7.00 W/kg = 8.45 dBW/kg B44 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 719 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Body; Medium parameters used: f = 2450 MHz; σ = 2.028 S/m; εr = 51.398; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-27-2018; Ambient Temp: 22.5°C; Tissue Temp: 21.9°C Probe: EX3DV4 - SN7406; ConvF(7.3, 7.3, 7.3) @ 2450 MHz; Calibrated: 5/22/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn859; Calibrated: 5/22/2018 Phantom: Twin-SAM V5.0 Back Right; Type: QD 000 P40 CD; Serial: 1692 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2450 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 11.1 W/kg SAR(1 g) = 5.34 W/kg Deviation(1 g) = 6.59% 0 dB = 8.93 W/kg = 9.51 dBW/kg B45 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2600 MHz; Type: D2600V2; Serial: 1004 Communication System: UID 0, CW; Frequency: 2600 MHz; Duty Cycle: 1:1 Medium: 2600 Body Medium parameters used: f = 2600 MHz; σ = 2.203 S/m; εr = 50.886; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-26-2018; Ambient Temp: 22.6°C; Tissue Temp: 23.5°C Probe: ES3DV3 - SN3319; ConvF(4.33, 4.33, 4.33) @ 2600 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2600 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 12.4 W/kg SAR(1 g) = 5.54 W/kg Deviation(1 g) = 1.09% 0 dB = 7.29 W/kg = 8.63 dBW/kg B46 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2600 MHz; Type: D2600V2; Serial: 1126 Communication System: UID 0, CW; Frequency: 2600 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2600 MHz; σ = 2.218 S/m; εr = 51.418; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-02-2018; Ambient Temp: 21.6°C; Tissue Temp: 23.3°C Probe: ES3DV3 - SN3319; ConvF(4.33, 4.33, 4.33) @ 2600 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2600 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 11.8 W/kg SAR(1 g) = 5.39 W/kg; SAR(10 g) = 2.38 W/kg Deviation(1 g) = -0.37%; Deviation(10 g) = -2.46% 0 dB = 7.17 W/kg = 8.56 dBW/kg B47 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2600 MHz; Type: D2600V2; Serial: 1126 Communication System: UID 0, CW; Frequency: 2600 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2600 MHz; σ = 2.203 S/m; εr = 51.338; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-05-2018; Ambient Temp: 22.7°C; Tissue Temp: 21.3°C Probe: ES3DV3 - SN3319; ConvF(4.33, 4.33, 4.33) @ 2600 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2600 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 11.9 W/kg SAR(10 g) = 2.41 W/kg Deviation(10 g) = -1.23% 0 dB = 7.29 W/kg = 8.63 dBW/kg B48 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2600 MHz; Type: D2600V2; Serial: 1126 Communication System: UID 0, CW; Frequency: 2600 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2600 MHz; σ = 2.172 S/m; εr = 51.779; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-09-2018; Ambient Temp: 21.8°C; Tissue Temp: 22.8°C Probe: ES3DV3 - SN3319; ConvF(4.33, 4.33, 4.33) @ 2600 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2600 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 11.9 W/kg SAR(1 g) = 5.48 W/kg Deviation(1 g) = 1.29% 0 dB = 7.16 W/kg = 8.55 dBW/kg B49 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 2600 MHz; Type: D2600V2; Serial: 1071 Communication System: UID 0, CW; Frequency: 2600 MHz; Duty Cycle: 1:1 Medium: 2450 Body Medium parameters used: f = 2600 MHz; σ = 2.22 S/m; εr = 52.401; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 01-07-2019; Ambient Temp: 22.6°C; Tissue Temp: 21.6°C Probe: ES3DV3 - SN3319; ConvF(4.33, 4.33, 4.33) @ 2600 MHz; Calibrated: 3/13/2018 Sensor-Surface: 3mm (Mechanical Surface Detection) Electronics: DAE4 Sn1368; Calibrated: 3/7/2018 Phantom: LeftTwin-SAM V5.0; Type: QD 000 P40 CD; Serial: TP1375 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 2600 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 12.2 W/kg SAR(1 g) = 5.52 W/kg Deviation(1 g) = 1.85% 0 dB = 7.32 W/kg = 8.65 dBW/kg B50 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 3500 MHz; Type: D3500V2; Serial: 1055 Communication System: UID 0, CW; Frequency: 3500 MHz; Duty Cycle: 1:1 Medium: 3500-3700 Body Medium parameters used: f = 3500 MHz; σ = 3.176 S/m; εr = 51.13; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-27-2018; Ambient Temp: 22.8°C; Tissue Temp: 20.6°C Probe: EX3DV4 - SN3914; ConvF(6.81, 6.81, 6.81) @ 3500 MHz; Calibrated: 2/14/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V8.0; Type: QD 000 P41 Ax; Serial: 1966 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 3500 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x8)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 16.3 W/kg SAR(1 g) = 6.06 W/kg; SAR(10 g) = 2.27 W/kg Deviation(1 g) = -6.19%; Deviation(10 g) = -5.81% 0 dB = 11.8 W/kg = 10.72 dBW/kg B51 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 3700 MHz; Type: D3700V2; Serial: 1002 Communication System: UID 0, CW; Frequency: 3700 MHz; Duty Cycle: 1:1 Medium: 3500-3700 Body Medium parameters used (interpolated): f = 3700 MHz; σ = 3.412 S/m; εr = 50.772; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-27-2018; Ambient Temp: 22.8°C; Tissue Temp: 20.6°C Probe: EX3DV4 - SN3914; ConvF(6.64, 6.64, 6.64) @ 3700 MHz; Calibrated: 2/14/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V8.0; Type: QD 000 P41 Ax; Serial: 1966 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 3700 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x8)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 18.2 W/kg SAR(1 g) = 6.37 W/kg; SAR(10 g) = 2.32 W/kg Deviation(1 g) = -2.00%; Deviation(10 g) = 0.43% 0 dB = 12.7 W/kg = 11.04 dBW/kg B52 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5250 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used (interpolated): f = 5250 MHz; σ = 5.413 S/m; εr = 48.971; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-18-2018; Ambient Temp: 23.0°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7357; ConvF(4.78, 4.78, 4.78) @ 5250 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5250 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 14.3 W/kg SAR(10 g) = 1.01 W/kg Deviation(10 g) = -6.48% 0 dB = 8.66 W/kg = 9.38 dBW/kg B53 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5600 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used: f = 5600 MHz; σ = 5.888 S/m; εr = 48.371; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-18-2018; Ambient Temp: 23.0°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7357; ConvF(4.2, 4.2, 4.2) @ 5600 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5600 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 16.9 W/kg SAR(10 g) = 1.08 W/kg Deviation(10 g) = -2.70% 0 dB = 9.29 W/kg = 9.68 dBW/kg B54 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5750 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used (interpolated): f = 5750 MHz; σ = 6.086 S/m; εr = 48.165; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 11-18-2018; Ambient Temp: 23.0°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7357; ConvF(4.21, 4.21, 4.21) @ 5750 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5750 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 16.5 W/kg SAR(10 g) = 1.02 W/kg Deviation(10 g) = -3.77% 0 dB = 8.80 W/kg = 9.44 dBW/kg B55 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5250 MHz; Duty Cycle: 1:1 Medium: 5GHz Body Medium parameters used (interpolated): f = 5250 MHz; σ = 5.399 S/m; εr = 47.703; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-03-2018; Ambient Temp: 23.0°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7357; ConvF(4.78, 4.78, 4.78) @ 5250 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5250 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 14.1 W/kg SAR(1 g) = 3.58 W/kg Deviation(1 g) = -7.01% 0 dB = 8.42 W/kg = 9.25 dBW/kg B56 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5600 MHz; Duty Cycle: 1:1 Medium: 5GHz Body Medium parameters used: f = 5600 MHz; σ = 5.888 S/m; εr = 47.127; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-03-2018; Ambient Temp: 23.0°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7357; ConvF(4.2, 4.2, 4.2) @ 5600 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5600 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 16.7 W/kg SAR(1 g) = 3.82 W/kg Deviation(1 g) = -3.54% 0 dB = 9.45 W/kg = 9.75 dBW/kg B57 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5750 MHz; Duty Cycle: 1:1 Medium: 5GHz Body Medium parameters used (interpolated): f = 5750 MHz; σ = 6.153 S/m; εr = 46.816; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-03-2018; Ambient Temp: 23.0°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7357; ConvF(4.21, 4.21, 4.21) @ 5750 MHz; Calibrated: 4/18/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1407; Calibrated: 4/11/2018 Phantom: SAM with CRP v5.0 Front; Type: QD000P40CD; Serial: 1646 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5750 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 17.3 W/kg SAR(1 g) = 3.87 W/kg Deviation(1 g) = 1.71% 0 dB = 11.0 W/kg = 10.41 dBW/kg B58 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5250 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used (interpolated): f = 5250 MHz; σ = 5.421 S/m; εr = 47.944; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-26-2018; Ambient Temp: 21.3°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7308; ConvF(4.48, 4.48, 4.48) @ 5250 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1630 Measurement SW: DASY52, Version 52.10; SEMCAD X Version 14.6.12 (7450) 5250 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 14.6 W/kg SAR(1 g) = 3.6 W/kg Deviation(1 g) = -6.49% 0 dB = 8.56 W/kg = 9.32 dBW/kg B59 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5600 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used: f = 5600 MHz; σ = 5.939 S/m; εr = 47.285; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-26-2018; Ambient Temp: 21.3°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7308; ConvF(4, 4, 4) @ 5600 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1630 Measurement SW: DASY52, Version 52.10; SEMCAD X Version 14.6.12 (7450) 5600 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 17.5 W/kg SAR(1 g) = 3.89 W/kg Deviation(1 g) = -1.77% 0 dB = 9.63 W/kg = 9.84 dBW/kg B60 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5750 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used (interpolated): f = 5750 MHz; σ = 6.154 S/m; εr = 47.01; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 12-26-2018; Ambient Temp: 21.3°C; Tissue Temp: 21.5°C Probe: EX3DV4 - SN7308; ConvF(4.18, 4.18, 4.18) @ 5750 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1630 Measurement SW: DASY52, Version 52.10; SEMCAD X Version 14.6.12 (7450) 5750 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 16.1 W/kg SAR(1 g) = 3.47 W/kg Deviation(1 g) = -8.80% 0 dB = 8.59 W/kg = 9.34 dBW/kg B61 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5250 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used (interpolated): f = 5250 MHz; σ = 5.402 S/m; εr = 47.349; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 01-03-2019; Ambient Temp: 21.5°C; Tissue Temp: 21.0°C Probe: EX3DV4 - SN7308; ConvF(4.48, 4.48, 4.48) @ 5250 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1630 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5250 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 15.1 W/kg SAR(1 g) = 3.58 W/kg Deviation(1 g) = -7.01% 0 dB = 8.58 W/kg = 9.33 dBW/kg B62 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5600 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used: f = 5600 MHz; σ = 5.888 S/m; εr = 46.674; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 01-03-2019; Ambient Temp: 21.5°C; Tissue Temp: 21.0°C Probe: EX3DV4 - SN7308; ConvF(4, 4, 4) @ 5600 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1630 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5600 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 18.5 W/kg SAR(1 g) = 3.9 W/kg Deviation(1 g) = -1.52% 0 dB = 9.75 W/kg = 9.89 dBW/kg B63 PCTEST ENGINEERING LABORATORY, INC. DUT: Dipole 5 GHz; Type: D5GHzV2; Serial: 1191 Communication System: UID 0, CW; Frequency: 5750 MHz; Duty Cycle: 1:1 Medium: 5 GHz Body Medium parameters used (interpolated): f = 5750 MHz; σ = 6.138 S/m; εr = 46.378; ρ = 1000 kg/m3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 01-03-2019; Ambient Temp: 21.5°C; Tissue Temp: 21.0°C Probe: EX3DV4 - SN7308; ConvF(4.18, 4.18, 4.18) @ 5750 MHz; Calibrated: 8/23/2018 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 10/3/2018 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1630 Measurement SW: DASY52, Version 52.10;SEMCAD X Version 14.6.12 (7450) 5750 MHz System Verification at 17.0 dBm (50 mW) Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm; Graded Ratio: 1.4 Peak SAR (extrapolated) = 17.3 W/kg SAR(1 g) = 3.5 W/kg Deviation(1 g) = -8.02% 0 dB = 8.81 W/kg = 9.45 dBW/kg B64 APPENDIX C: PROBE CALIBRATION © 2019 PCTEST Engineering Laboratory, Inc.
Source Exif Data [exif.tools]:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2019:01:29 10:28:16-05:00 Creator : Acrobat PDFMaker 15 for Word Modify Date : 2019:01:29 10:33:13-05:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Metadata Date : 2019:01:29 10:33:13-05:00 Creator Tool : Acrobat PDFMaker 15 for Word Format : application/pdf Document ID : uuid:9556d6b7-719a-4222-b0ad-58efce03cd91 Instance ID : uuid:9c286bfd-660a-4f9b-bd04-61145bb88a79 Producer : Adobe PDF Library 15.0 Page Count : 190